Fluid and electrolyte regulation in space.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R L Hughson.
Explore the source record for details and available documents.
During transitions in work rate, O2 uptake (VO2) kinetics at the working tissue level might be rate limited by O2 transport and/or by O2 utilization. A computer model with parallel working and non-working tissue compartments, connected to an ideal lung by a variable-sized venous blood volume, was developed to study this. The time constant for working tissue O2 demand (tau T) was set by a first-order linear metabolic response. The model attempted to replicate the VO2 response at the alveolar level of a single subject performing step transitions on a cycle ergometer from 25 to 105 W [total lag time (equivalent to 63% increase above baseline) = 40.2 s]. Measured cardiac output kinetics (total lag time = 44.1 s) were used as a model parameter. Blood flow to the nonworking tissue (QNW) was kept constant at 4.5 or 5.0 l/min. A critical PO2 of 20 Torr was set, and the Bohr effect on the O2-hemoglobin dissociation curve was included. The "best" simulation had tau T = 36 s, QNW = 4.5 l/min, and venous blood volume = 2 liters and was not O2 transport limited. The approximation to the real data was good in all but the phase 1 response, where the model underpredicted the measured response. However, when QNW was increased to 5.0 l/min, the model was O2 transport limited; yet the predicted VO2 response at the alveolar level was not notably different from the subject's data.(ABSTRACT TRUNCATED AT 250 WORDS)
We introduce our recent approach to study autonomic nervous system control of heart rate during exercise by means of heart rate variability (HRV) spectral analysis with special reference to its relationship to ventilatory threshold (Tvent). The rationale for the study was that HRV has been shown to reflect (cardiac) parasympathetic and sympathetic nervous system (PNS and SNS, respectively) activity, together with the underlying complexity of cerebral autonomic system in terms of fractal dimension (DF) of HRV time series. The experimental results showed that PNS was markedly reduced below Tvent, that the rate of change in sympathoadrenal activity indicators (plasma norepinephrine and epinephrine concentrations and SNS indicator) was enhanced above Tvent, and that these changes in PNS and SNS indicators were associated with the appearance of the low-dimensional (low DF) dynamics that might reflect less complex autonomic activity. These findings have been considered with respect to implication for clinical cardiology.
The dynamics of ventilation (VE), oxygen uptake (VO2), carbon dioxide output (VCO2), and heart rate (fc) were studied in 12 healthy young men during upright and supine exercise. Responses to maximal and to two different types of submaximal exercise tests were contrasted. During incremental exercise to exhaustion, the maximal work rate, VO2max, VEmax, fc,max, and ventilatory threshold were all significantly reduced in supine compared to upright exercise (P less than 0.01-0.001). Following step increases or decreases in work rate between 25 W and 105 W, both VO2 and VCO2 responded more slowly in supine than upright exercise. Dynamics were also studied in two different pseudorandom binary-sequence (PRBS) exercise tests, with the work rate varying between 25 W and 105 W with either 5-s or 30-s durations of each PRBS unit. In both of these tests, there were no differences caused by body position in the amplitude or phase shifts obtained from Fourier analysis for any observed variable. These data show that the body position alters the dynamic response to the more traditional step increase in work rate, but not during PRBS exercise. It is speculated that the elevation of cardiac output observed with supine exercise in combination with the continuously varying work-rate pattern of the PRBS exercise allowed adequate, perhaps near steady-state, perfusion of the working muscles in these tests, whereas at the onset of a step increase in work rate, greater demands were placed on the mechanisms of blood flow redistribution.
The cardiovascular responses to a 10-min 1.22 rad (70 degrees) head-up tilt orthostatic tolerance test (OST) was observed in eight healthy men following each of a 5-min supine baseline (control), 4 h of 0.1 rad (6 degrees) head-down tilt (HDT), or 4 h 0.52 rad (30 degrees) head-up tilt (HUT). An important clinical observation was presyncopal symptoms in six of eight subjects following 4 h HDT, but in no subjects following 4 h HUT. Immediately prior to the OST, there were no differences in heart rate, stroke volume, cardiac output, mean arterial pressure and total peripheral resistance for HDT and HUT. However, stroke volume and cardiac output were greater for the control group. Mean arterial pressure for the control group was less than HDT but not HUT. Over the full 10-min period of OST, the mean arterial pressure was not different between groups. Heart rate increased to the same level for all three treatments. Stroke volume decreased across the full time period for control and HDT, but only at 3 and 9 min for HUT. There was a higher total peripheral resistance in the HDT group than control or HUT. The pre-ejection period to left ventricular ejection time ratio was less in HDT than for control or HUT groups. These data indicate a rapid adaptation of the cardiovascular system to 4 h HDT that appears to be inappropriate on reapplication of a head to foot gravity vector. We speculate that the cause of the impaired orthostatic tolerance is decreased tone in venous capacitance vessels so that venous return is inadequate.
The purpose of this study was to examine whether the ventilatory threshold (Thv) would give the maximal lactate steady state ([la]ss, max), which was defined as the highest work rate (W) attained by a subject without a progressive increase in blood lactate concentration [la]b at constant intensity exercise. Firstly, 8 healthy men repeated ramp-work tests (20 W.min-1) on an electrically braked cycle ergometer on different days. During the tests, alveolar gas exchange was measured breath-by-breath, and the W at Thv (WThv) was determined. The results of two-way ANOVA showed that the coefficient of variation of a single WThv determination was 2.6%. Secondly, 13 men performed 30-min exercise at WThv (Thv trial) and at 4.9% above WThv (Thv + trial), which corresponded to the 95% confidence interval of the single determination. The [la]b was measured at 15 and 30 min from the onset of exercise. The [la]b at 15 min (3.15 mmol.l-1, SEM 0.14) and at 30 min (2.95 mmol.l-1, SEM 0.18) were not significantly different in Thv trial. However, the [la]b of Thv + trial significantly increased (P less than 0.05) from 15 min (3.62 mmol.l-1, SEM 0.36) to 30 min (3.91 mmol.l-1, SEM 0.40). These results indicate that Thv gives the [la]ss, max, at which one can perform sustained exercise without continuous [la]b accumulation.
The effects of correct alignment of the ventilation and fractional gas concentration during breath-by-breath calculation of oxygen uptake (VO2) have been examined during exercise in four subjects, at each of 50, 100, 150, and 200 W. Data were analyzed using lagtimes in the range of 200 to 400 msec to align ventilation with gas fraction. VO2 was markedly affected by lagtime. Calculated values of VO2 at 200 W ranged from 1953 +/- 55 (mean +/- SEM), to 2583 +/- 29, to 2843 +/- 28 ml.min-1 with lagtimes of 200, 310, and 400 msec, respectively. Mean values from a mixing box system did not differ significantly from the mean of the breath-by-breath data collection with a lagtime of 310 msec. Additional computations have shown that temperature correction can markedly affect calculated ventilatory volumes and N2 balance. VO2 was not changed because of the compensation from the calculated effects of changes in lung gas stores.
The most commonly observed effect of beta-blockade on cardiovascular function has been a reduction in heart rate both at rest and during exercise. The body attempts to compensate by increasing stroke volume and (or) increasing the extraction of O2 from the blood to maintain O2 delivery to the muscle. This paper examines the roles of muscle mass involved in the exercise as well as the time course of change in cardiac output and peripheral blood flow in an attempt to understand whether O2 supply is limited by beta-blockade. Experiments are reported in which the kinetics of cardiac output response at the onset of submaximal cycle exercise were slowed in subjects taking oral propranolol. Taken in consideration with other data from our laboratory and with data in the literature, it was concluded that beta-blockade does impair O2 transport. The degree of impairment is dependent on the total muscle mass involved and the metabolic demand.
Spectral analysis of heart rate variability (HRV) might provide an index of relative sympathetic (SNS) and parasympathetic nervous system (PNS) activity during exercise. Eight subjects completed six 17-min submaximal exercise tests and one resting measurement in the upright sitting position. During submaximal tests, work rate (WR) was increased for the initial 3 min in a ramp fashion until it reached constant WRs of 20 W, or 30, 60, 90, 100, and 110% of the predetermined ventilatory threshold (Tvent). Ventilatory profile and alveolar gas exchange were monitored breath by breath, and beat-to-beat HRV was measured as R-R intervals of an electrocardiogram. Spectral analysis was applied to the HRV from 7 to 17 min. Low-frequency (0-0.15 Hz) and high-frequency (0.15-1.0 Hz) areas under power spectra (LO and HI, respectively) were calculated. The indicator of PNS activity (HI) decreased dramatically (P less than 0.05) when the subjects exercised compared with rest and continued to decrease until the intensity reached 60% Tvent. The indicator of SNS activity (LO/HI) remained unchanged up to 100% Tvent, whereas it increased abruptly (P less than 0.05) at 110% Tvent. The results suggested that (cardiac) PNS activity decreased progressively from rest to a WR equivalent to 60% Tvent, and SNS activity increased only when exercise intensity exceeded Tvent.
Heart rate variability (HRV) spectra are typically analyzed for the components related to low- (less than 0.15 Hz) and high- (greater than 0.15 Hz) frequency variations. However, there are very-low-frequency components with periods up to hours in HRV signals, which might smear short-term spectra. We developed a method of spectral analysis suitable for selectively extracting very-low-frequency components, leaving intact the low- and high-frequency components of interest in HRV spectral analysis. Computer simulations showed that those low-frequency components were well characterized by fractional Brownian motions (FBMs). If the scale invariant, or self-similar, property of FBMs is considered a new time series (x') was constructed by sampling only every other point (course graining) of the original time series (x). Evaluation of the cross-power spectra between these two (Sxx') showed that the power of the FBM components was preserved, whereas that of the harmonic components vanished. Subtraction of magnitude of Sxx from the autopower spectra of the original sequence emphasized only the harmonic components. Application of this method to HRV spectral analyses indicated that it might enable one to observe more clearly the low- and high-frequency components characteristic of autonomic control of heart rate.
Pseudorandom binary sequence (PRBS) exercise tests involve repeated switching between two work rates (WR) according to a computer-generated pattern. This paper presents an approach to analysis of O2 uptake (VO2) in the time domain. First, the autocorrelation function (ACF) of the input WR was recognized to be a triangular-shaped pulse that can be taken to be equivalent to a ramp increase followed by a ramp decrease in WR. Then the cross-correlation function of the input (WR) and the output (VO2) was treated as if it were the response to a triangular-shaped pulse. The cross-correlation function was analyzed by fitting a linear summation of the ramp form of a two-component exponential function to this triangular pulse. VO2 responses of eight subjects were obtained from two different PRBS tests, as well as step changes in WR. The first PRBS test consisted of 15 units, each 30 s in duration. Its ACF had a base width of 60 s. The ramp increase-ramp decrease model fit the data throughout the range of response. The second PRBS test had 63 units, each 5 s in duration; thus its ACF base width was 10 s. Again, the ramp model fit adequately. The data from the second PRBS test could be fit by the impulse form of the two-component exponential equation, although the fit in the first 30 s tended to be poorer. The time constants of VO2 dynamics estimated from step and PRBS tests were not significantly different. PRBS tests can be analyzed in the time domain, and the indicators of system dynamics reflect physiological properties similar to those investigated during step changes in WR.
The kinetics of O2 up-take (VO2), CO2 output (VCO2), ventilation (VE), and heart rate (HR) were studied during exercise in normoxia and hypoxia [inspired O2 fraction (FIO2) 0.14]. Eight male subjects each completed 6 on- and off-step transitions in work rate (WR) from low (25 W) to moderate (100-125 W) levels and a pseudorandom binary sequence (PRBS) exercise test in which WR was varied between the same WRs. Breath-by-breath data were linearly interpolated to yield 1-s values. After the first PRBS cycle had been omitted as a warm-up, five cycles were ensemble-averaged before frequency domain analysis by standard Fourier methods. The step data were fit by a two-component (three for HR) exponential model to estimate kinetic parameters. In the steady state of low and moderate WRs, each value of VO2, VCO2, VE, and HR was significantly greater during hypoxic than normoxic exercise (P less than 0.05) with the exception of VCO2 (low WR). Hypoxia slowed the kinetics of VO2 and HR in on- and off-step transitions and speeded up the kinetics of VCO2 and VE in the on-transition and of VE in the off-transition. Frequency domain analysis confined to the range of 0.003-0.019 Hz for the PRBS tests indicated reductions in amplitude and greater phase shifts in the hypoxic tests for VO2 and HR at specific frequencies, whereas amplitude tended to be greater with little change in phase shift for VCO2 and VE during hypoxic tests.(ABSTRACT TRUNCATED AT 250 WORDS)
The effect of beta-adrenergic blockade on torque output and leg blood flow was examined in seven healthy young men during repeated maximal isometric voluntary contractions of the triceps surae muscle group. Exercise was performed in either a bent- or straight-leg position during each of four drug treatments: placebo, propranolol, metoprolol, oxprenolol. Contractions were sustained for 5 s with 5 s relaxation for a total of 10 min followed by a 10-min recovery. Leg blood flow was measured during the 5 s relaxation separating contractions using strain gauge plethysmography. Torque output decreased during the 10-min contractions with no differences between the four drug treatments. Leg blood flow was lower with beta-blockade during the initial stages of exercise and recovery in the bent-leg position but no differences were observed after 3 min exercise or recovery. Leg blood flow in the straight-leg position was not different between any of the four drug treatments, but it was significantly less than in bent-leg exercise. The lower blood flows during the initial stages of exercise in the beta-blocked conditions probably reflect a slowing of the central cardiovascular response because of beta 1-receptor blockade of the heart rather than on the beta 2-receptors effects on peripheral vascular resistance. It is concluded that local vasodilator substances released from the working muscle may play a more important role than beta 2-receptor stimulation of smooth muscle in skeletal muscle resistance vessels in regulating local muscle blood flow during maximal exercise of the triceps surae muscle group.
The effect of beta-adrenergic blockade on the dynamic response characteristics of oxygen uptake (VO2) was examined in seven healthy men. Cycle ergometer exercise consisted of a pseudorandom binary sequence (PRBS) with 15 units per sequence, each unit lasting 15 s, for a total period of 225 s. Work rate was either 25 W or 125 W. Six identical sequences were performed continuously in a single exercise test. Each subject was studied on three occasions after 48 h treatment of placebo (CON); a nonselective beta-blocker, propranolol (PROP); and a beta 1-selective blocker, metoprolol (MET). VO2 was measured breath-by-breath. The data were analyzed in the frequency domain by Fourier analysis to yield amplitude and phase shift coefficients for the relationship between the input work rate and output VO2. Time domain analysis was performed on the cross-correlational analysis of VO2 (output).work rate (input) to determine the total lag time. The amplitude of the VO2.W-1 relationship was lower (P less than 0.0022) and the phase shift was greater (P less than 0.0039) with beta-blockade compared to CON; no differences were found between PROP and MET. The total lag time was longer (P less than 0.0053) in PROP (34.3 +/- 2.2 s) and MET (34.4 +/- 1.6 s) compared to CON (29.8 +/- 1.3 s). These data indicate that beta-adrenergic blockade causes a significant slowing of kinetics of the O2 transport system as determined by both frequency and time domain analysis. In addition, the PRBS exercise test is a sensitive indicator of change in function of the O2 transport system.
The dynamic response of oxygen uptake (VO2) was investigated with two different cycle ergometer tests in which the work rate changed as a pseudorandom binary sequence (PRBS). One sequence had 15 units, each of 30-s duration for a total of 450 s (PRBS1). The second had 63 units, each of 5-s duration for a total of 315 s (PRBS2). The useful range of frequencies available for investigation of the dynamic characteristics of the VO2 response as described by their bandwidth were 0.002-0.013 Hz for PRBS1 and 0.003-0.089 Hz for PRBS2. Eight subjects each completed both PRBS tests. Data from four or five consecutive sequences were ensemble averaged to reduce the biological noise. A Fourier analysis was then conducted, with the range of frequencies investigated spanning those of the bandwidth for PRBS2. This was up to the 28th harmonic. For PRBS1, the VO2 response could be adequately reconstructed by including Fourier coefficients only up to the 5th harmonic. In contrast, for PRBS2, there was still a clear pattern in the residuals at the 5th harmonic. The data were not adequately reconstructed until higher-frequency components up to the 28th harmonic were included. Evidence for this came from analysis of the mean square error. The mean square error at the 28th harmonic was reduced to 83 +/- 8% of the mean square error at the 5th harmonic for PRBS1 and to 31 +/- 3% for PRBS2 (P less than 0.0001). These data obtained by Fourier analysis and reconstructed for comparison with the original VO2 response indicate the presence of a high-frequency component that was not apparent when a test with a smaller bandwidth was used as the work rate forcing.
The dynamic response characteristics of the oxygen uptake (VO2) response were investigated during upright cycle ergometer exercise in six healthy male volunteers. The exercise test consisted of a pseudorandom binary sequence (PRBS) with 15 units per sequence, each unit 15 s long, for a total period of 225 s. Six identical sequences were completed in a single test session. Each subject exercised under both normoxic and hypoxic (FIO2 = 14%) conditions. VO2 was measured breath-by-breath. The data were analyzed in the frequency domain by Fourier analysis to yield amplitude and phase shift coefficients for the relationship between the input work rate and the output responses of VO2 and heart rate (HR). The amplitude of the VO2/work rate was significantly reduced by hypoxia compared to normoxia over a wide range of frequencies. The mean VO2 was not different between hypoxia and normoxia. The phase shift for the VO2/work rate response was significantly greater for hypoxia than normoxia. The amplitude of the HR/work rate relationship was not significantly altered by hypoxia; however, the mean HR was higher during hypoxia. The phase shift of the HR/work rate response was significantly different between hypoxia and normoxia only at certain frequencies. These data indicate that the effects of hypoxia on the cardiorespiratory response to exercise can be characterized by the use of PRBS exercise and Fourier analysis techniques. A significant reduction in the ability of the cardiorespiratory system to adapt to changes in work rate appears to be caused by a reduction in the arterial O2 content.
The cardiovascular responses to 4 h of 6 degrees head-down tilt (HDT) were compared to those of 4 h of 30 degrees head-up tilt (HUT) following a period of 1 h baseline in the 30 degrees HUT position. Eight healthy males completed each tilt position. Immediately on assuming HDT, heart rate decreased slightly from baseline, but did not differ from HUT. Stroke volume and cardiac output both increased significantly by as much as 54% and 26%, respectively, in the first minute of HDT. The difference between HDT and HUT was no longer present after 30 min. Mean arterial blood pressure was unchanged throughout 4 h or HUT or HDT. The ratio of pre-injection period to left ventricular ejection time was significantly decreased across all 4 h of HDT. Plasma volume was slightly elevated over the 4 h of HDT, while plasma hemoglobin concentration was significantly reduced. No evidence of a diuresis was found with 4 h HDT. Plasma catecholamines were not different between HDT and HUT. The present results show that the immediate transition from a HUT to a HDT position causes a dramatic change in cardiovascular variables. These changes are generally transient with baseline values resumed by many variables within 30 min of exposure to 6 degrees HDT.
Explore the source record for details and available documents.