PubMed Health⌕ Search

Biomedical subjects

R L Kormos

Publications and source records attributed to R L Kormos.

At least 145 records · Page 8Linked to original sources

Morbidity and mortality in mitral valve surgery.

To develop strategies for the management of high-risk patients, contemporary risk factors for operative mortality and postoperative ventricular dysfunction were identified in 214 patients undergoing mitral valve surgery in 1982 and 1983. Thirty-eight preoperative and perioperative variables were prospectively collected and analyzed by univariate and multivariate statistics. The overall mortality was 4.6% and the incidence of postoperative low-output syndrome (LOS) was 18.7%. Forty-seven patients with coronary artery disease (CAD) had a higher mortality and incidence of LOS (as evidenced by the need for inotropic drugs or counterpulsation to maintain blood pressure) (those with CAD 15% mortality, 40% LOS; those without CAD 2% mortality, 13% LOS; p less than .05). The presence of unstable angina and ischemic mitral regurgitation further increased the risk. Age was also a predictor of outcome. Patients who died or had LOS were older (those who died, 65 +/- 7 years, those with LOS, 58 +/- 11 years) than patients who survived and did not have postoperative dysfunction (those who survived, 53 +/- 11; those with no LOS, 53 +/- 11; p less than .01). Mitral regurgitation was associated with a higher (p less than .05) mortality and incidence of LOS (mortality 10.5%, LOS 36%; n = 76) than was mitral stenosis (mortality 0%, LOS 4%; n = 74) or mixed lesions (mortality 3%, LOS 15%; n = 64). In patients without CAD, mitral regurgitation remained a significant predictor of mortality and ventricular dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Subarachnoid hemorrhage due to a spinal cord hemangioblastoma: case report.

A case of solitary spinal hemangioblastoma with spontaneous subarachnoid hemorrhage is presented. There was no features to distinguish the subarachnoid hemorrhage in this case from that due to an intracranial lesion. However, mild sensory symptoms involving the left arm and leg had preceded the hemorrhage by several months. The lesion was detected by cerebral angiography and computed tomographic scanning, and the diagnosis was confirmed at operation. A small syrinx was noted, and the lesion was totally removed without causing any deficit, despite its origin from the dorsum of the spinal cord. The tumor contained a false aneurysm, which had been visualized angiographically.

Adult↗

PTSD in heart transplant recipients and their primary family caregivers.

Posttraumatic stress disorder associated with transplantation (PTSD-T) is a complication for some heart transplant recipients. By using a structured, standardized interview and DSM-III-R criteria, the authors examined whether recipients (n = 158) and their family caregivers (n = 142) showed similar PTSD-T rates and clinical characteristics during the first year posttransplant. Among the recipients, 10.5% met full criteria for the disorder and an additional 5% were probable cases. Among the caregivers, 7.7% met full criteria and an additional 11.0% were probable cases. Severity and duration of disorder were similar across the groups. Being female, having a history of psychiatric illness, and having lower friend support were increased risks for PTSD-T.

Adult↗

Two-dimensional echocardiographic automated border detection accurately reflects changes in left ventricular volume.

The objective of this study was to determine the relationship of on-line measurements of left ventricular cavity area generated by echocardiographic automated border detection to true volume measured by an intraventricular balloon in an isovolumically contracting isolated canine heart preparation. Seven excised dog hearts had placement of an intraventricular balloon and were perfused in an ex vivo apparatus. Left ventricular area data from the midventricular short-axis plane and pressure data were recorded on a computer through a customized hardware and software interface with the ultrasound system. Left ventricular volumes were varied from 5 ml to maximal values (30 to 40 ml) at 1-milliliter increments. Three increasing and decreasing volume ramps were analyzed on each of seven hearts for a total of 1260 simultaneous measurements. Linear regression analysis correlated mean automated border detection area with absolute volume from each preparation. A predominantly linear relationship was observed with an average correlation of r = 0.97 (y = 0.16x-0.69, SEE = 0.31 cm2, p < 0.01). Left ventricular area measures for six of seven dogs varied little during isovolumic contraction (< 0.4 cm2) but did show a systematic cardiac cycle-related variability in one dog (28% change in area, maximum to minimum, over all volumes). In conclusion, the relationship between cross-sectional area and left ventricular volume was predominantly linear and varied little during isovolumic contractions in the normal canine left ventricle. Echocardiographic automated border detection appears to be a promising method to reflect changes in left ventricular volume.

Animals↗

Evaluation of right ventricular function during clinical left ventricular assistance.

Hemodynamic and mechanical parameters of right ventricular (RV) performance were measured in eight patients undergoing left ventricular (LV) assistance as a bridge to cardiac transplantation. All patients, even those with impaired RV performance, survived support and transplantation. The reduction of LV afterload produced by the left ventricular assist system (LVAS) results in RV afterload reduction, which permits even the marginal RV to function adequately during LVAS support.

Adult↗

Characteristics of blood rheology in patients during Novacor left ventricular assist system support.

Blood rheologic properties were studied in 11 patients on Novacor LVAS support (1-126 days) as a bridge to transplantation. Overall, these patients showed slight increases in mean blood viscosity and red cell rigidity. Their mean plasma fibrinogen was in the upper normal range. However, the degree of rheologic change observed, and the individual factors affected most, were unique to each patient and hemorheologic results correlated well with the patient's clinical status.

Adult↗

Erythrocyte deformability in patients on left ventricular assist systems.

Preliminary hemorheologic studies using clinical filtration techniques on blood cell suspensions have suggested that changes in erythrocyte (RBC) deformability occur during left ventricular assist system (LVAS) support. In the biophysics literature, it is generally accepted that the elastic properties of the RBC membrane complex affect the microcirculatory deformability of the whole cell (cytoplasmic pathologies excepted). This paper compares single cell measurements of the surface shear elastic modulus, mu, of the RBC membrane complex (determined using micropipette aspiration) to available clinical filtration pressure data during Novacor LVAS support, over 33 and 126 days in four patients.

Adult↗

Quantitation of right ventricular shape changes after left ventricular assist device implantation.

Complex effects of left (LV) and right ventricular (RV) interaction account for changes in RV function during LV assist device (LVAD) support. It has been hypothesized that changes in RV cross-sectional shape (RVS) may be a contributing factor in the development of RV dysfunction during LVAD support. To test the hypothesis that the RVS would become more circular as a result of septal shift during LVAD support, 13 patients were studied before and after LVAD implantation. The shape of the RV was quantified using a shape factor (SF) that was equal to (4 x pi x area)/P2, where P is the perimeter of RVS. The RV area and perimeter were measured from digitized images of the RV obtained by transesophageal echocardiography in patients before and after LVAD implantation. The group SF increased considerably after LVAD (SFpre = 0.78 +/- 0.12 versus SFpost = 0.88 +/- 0.07, p < 0.05). Patients were divided into three groups: 1) patients whose RV exhibited a low SF pre-LVAD that increased significantly, 2) those with a moderate SF pre-LVAD that increased slightly, and 3) those who had high pre-LVAD SF (< 0.90) that did not change. The decompression of the LV caused by LVAD implantation results in a shift of the septum from right to left, increasing SF. This increase is more pronounced in some patients. Quantitation of the degree of RV SF change may help predict the development of RV failure during LVAD support.

Adult↗

Development of an axial flow blood pump LVAS.

Nimbus, Inc., (Rancho Cordova, CA) and the University of Pittsburgh (Pittsburgh, PA) are collaborating to develop an implantable rotary blood pump that can be used as a left ventricular assist system (LVAS). The short-term goal of this project is to show that an LVAS based on this pump can operate safely and reliably during chronic implantations in animals. Work conducted to date includes in vitro testing of hydraulic performance, hemolysis, endurance demonstration, and flow visualization. Results indicate that the pump is capable of generating an output of up to 10 L/min at physiologic pressures. Associated electrical power to drive these pumps is in the range of 6-10 watts. One integrated pump was placed in a mock flow loop and operated continuously at a fixed speed (10,000 rpm), pressure (100 mmHg), and flow rate (6 L/min) for 90 days with no apparent difficulty. In vitro hemolysis test results have consistently ranged between 3-6 g of liberated hemoglobin/day, which is an acceptable range for chronic use. Two in vivo trials of 7 and 14 days were performed using calves, after which tests have been done using sheep as the animal model. Five short-term sheep experiments have been conducted with good results. Future studies will include implantations in sheep of 3 months duration.

Animals↗

Thrombin activity resides on LVAD Dacron inflow and outflow grafts.

Patients on left ventricular assist devices (LVADs) are at increased risk for thromboembolism, and they experience elevations in platelet release and thrombin activity indices during device implantation. The Dacron grafts that lead from the ventricle to the LVAD and back to the aorta may harbor thrombin activity and protect this thrombin from anticoagulant action. To investigate this possibility, specimens isolated from LVAD grafts at the time of device explantation or implantation were incubated with citrated platelet poor plasma (cPPP), cPPP and 2 U/ml of heparin, cPPP and 2 U/ml of recombinant hirudin (r-hirudin), or cPPP and 50 U/ml of heparin. Thrombin activity was measured by the increase in incubated cPPP fibrinopeptide A (FPA) concentrations over cPPP FPA levels, without material contact. A chromogenic substrate for thrombin verified the effects seen. Thrombin activity was found at comparable levels on both the inflow and outflow LVAD grafts at explantation. This activity was not inhibited by low concentrations of heparin, but 50 U/ml of heparin and 2 U/ml of r-hirudin reduced the activity. At graft implantation (after preclotting), thrombin activity was higher than at explantation, but susceptibility to inhibition by heparin was also significantly greater. These results confirm that the LVAD Dacron grafts harbor surface thrombin activity resistant to anticoagulation that may be a primary source for LVAD thrombogenicity.

Heart Ventricles↗

Differential regional function of the right ventricle during the use of a left ventricular assist device.

The use of a left ventricular assist device (LVAD) as a bridge to transplant is associated with a 52% incidence of RV failure requiring additional inotropic or mechanical support (RVAD). This study evaluated the differential performance of the RV free wall and septum to identify the need for additional RV support. Cross-sectional views of the RV were obtained immediately before, and 1 hr after, Novacor LVAS implantation in 12 consecutive patients using transesophageal echocardiography. Each image was divided into a free wall portion (FW) and a septal portion (SP) by grids drawn from the center of gravity of the end-diastolic endocardial outline to the junction between the FW and the SP. Percentage change between preimplant and postimplant for RV ejection fraction (RVEF), fractional area change for the FW (FAC-FW) and the SP (FAC-SP), and fractional shortening of the FW to SP distance (F-S) is reported for patients based upon the need for RV support: minimal (Group 1), maximal (Group 2). After LVAS implantation, patients showed a reduction in SP fractional area change. However, this reduction was most pronounced in Group 2. The degree of SP impairment may explain the mechanism of RV failure in patients on an LVAD.

Adolescent↗

Dynamic biventricular response to alterations in preload in patients undergoing left ventricular device implantation.

Ventricular interdependence is important for the successful use of a left ventricular assist device (LVAD) because the filling of the device depends on right ventricular (RV) function as well as the interactions between the ventricles. The pulmonary arterial (PAP) and systemic arterial (AP) response to inferior vena caval (IVC) occlusion before and after insertion of an LVAD in 15 patients was used to "dissect out" the determinants of these interactions. PAP and AP were recorded during each IVC occlusion and peak systolic values calculated for each beat. Linear regression analysis was used to calculate the slope (k) between peak systolic AP values and peak systolic PAP values. k, a measure of preload responsiveness of the heart, is predominantly linear. k is relatively "flat" in selected LV failure patients pre-LVAD but increases significantly (P < 0.001) after LVAD (0.67 +/- 0.55 vs. 2.71 +/- 1.39). The increase in this parameter after LVAD suggests that the loss of RV-to-LV ventricular interdependence in patients with congestive heart failure appears to recover somewhat once an LVAD is inserted.

Adolescent↗

Effect of perfluorochemical emulsion on blood trauma and hemorheology.

One of the major problems of development and improvement of heart assist devices is the reduction of blood cell damage. The extremely high levels of shear stress, turbulence, prolonged contact between blood and foreign surfaces, and other abnormal hydrodynamic circumstances have been shown to cause hemolysis, activation of platelets, and changes in mechanical properties of red blood cells. Hemolysis, in turn, can drastically increase red blood cell aggregation at low shear conditions. A new pharmacologic approach to reduce blood trauma and improve rheologic properties of blood subjected to mechanical stress was investigated. These experiments showed that the replacement of 20% of the plasma volume with Fluosol (Alpha Therapeutic Corp., Los Angeles, CA), a perfluorochemical that transports oxygen, reduced mechanical fragility of human (P < 0.01) and ovine (P = 0.054) red blood cells by approximately 30%. The same replacement of plasma with Fluosol reduced hemolysis (plasma free Hb) by approximately 40% compared to control (P < 0.05) during in vitro pumping of blood with a centrifugal pump. A 20% replacement of plasma volume with Fluosol remarkably reduced low shear blood viscosity (from 31.9 +/- 6.1 to 18.2 +/- 4.8 cP, for shear rate gamma = 0.277 sec-1) and erythrocyte sedimentation rate (from 16.7 +/- 9.2 to 3.1 +/- 3.1) mm/hr) in human blood. Decrease of these parameters indicates the reduction of red blood cell aggregation. Results of this study demonstrate the potential feasibility of Fluosol to improve mechanical properties of blood in patients with heart assist devices.

Animals↗

Protocol for releasing Novacor left ventricular assist system patients out-of-hospital.

Between September 1984 and April 1995, the Novacor left ventricular assist system (LVAS) has provided more than 13,000 days of mechanical circulatory support to cardiac transplant candidates in the United States and Europe. The duration of support of these 312 patients has ranged between 1 and 370 days, with an average support of 40 days, including use of the console based system and the wearable system. Of this group, 21% have been supported for more than 60 days, with an average support of 118 days. We have seen that patients who have been supported for more than 30 days have recovered from the effects of LVAS implant surgery and have shown a potential for rehabilitation from morbid congestive heart failure. Few changes to the pump settings or the medical orders have been needed after the third postoperative week. The reliability of the LVAS and the degree to which patients can be rehabilitated suggest that restricting patients to a hospital environment is unnecessary. In addition, the increasing wait for a donor heart, the quality of life that can be achieved, and the high cost of inpatient care make it desirable to discharge patients from the hospital and allow them to await a donor heart in a more home-like setting.

Ambulatory Care↗

Estimation of left ventricular function in patients with a left ventricular assist device.

Patients with profound left ventricular (LV) dysfunction supported by a left ventricular assist device (LVAD) may have recovery of LV function, but current methods for assessing this are difficult or not readily available. A new method to estimate LV performance was tested in 6 patients on LVAD (age, 47 +/- 12 years). Simultaneous measures of LV cross-sectional area (substitute for volume) using transesophageal echocardiographic automated border detection and femoral arterial pressure (substitute for LV ejection pressure) were recorded during brief periods on and off LVAD. During the LVAD off period, femoral arterial pressure and LV area signals were combined on-line to generate arterial pressure-LV area loops. The slope of the linear regression line connecting the end systolic points generated during LV filling after LVAD off was used as an estimate of end systolic elastance denoted by Ees. The average Ees was 3.8 +/- 3.1 mmHg/cm2. These values are significantly lower than those of 13 control patients (22.3 +/- 15.4 mmHg/cm2). This method of estimating Ees may be clinically useful in assessing LV recovery in patients on LVAD after extended support.

Adult↗

A gait-powered autologous battery charging system for artificial organs.

The quality of life of patients relying on electrically powered artificial organs is currently restricted by the limited energy availability provided by portable batteries. As these patients become increasingly ambulatory, and are developing more active lifestyles, this limitation grows more apparent. Coincidentally, these patients may themselves be capable of generating electrical power as a consequence of their physical activity. Extraction of this latent autologous energy could, in turn, be used to augment charging of internal batteries--thus untethering the patient from external power for extended periods of time. In this study, the viability of deriving energy associated with natural human ambulation has been evaluated. The kinematic components of gait were evaluated to identify the largest useful forces and moments that may be harnessed as an energy source, while presenting minimal "perceived" work for the patient. It was found that the ground reaction forces associated with the heel strike and toe-off phases of the gait represent the greatest potential for usable energy. This study uses a piezoelectric array within the midsole of the shoe for the conversion of mechanical to electric energy. This power could then be easily coupled in tandem with existing transcutaneous transformers for augmenting or temporarily replacing external power sources.

Artificial Organs↗

Effect of pulsatility and hemodynamic power on recovery of renal function.

Circulatory assist devices are used to treat patients awaiting cardiac transplantation to preserve life as well as to permit recovery of end-organ function. The efficacy of pulseless perfusion versus pulsatile perfusion in the recovery of end-organ function has not been fully determined. In this study, the efficacy of pulseless perfusion compared to pulsatile perfusion on the recovery of renal function after a 30 min period of normothermic ischemia was examined. Pigs were randomly assigned to four groups. In all groups, acute renal ischemia was induced by clamping both renal arteries for 30 min. Reperfusion for 120 min was performed using either pulsatile perfusion or pulseless perfusion at 65 +/- 1.6 mm Hg (Groups I [pulsatile] and II [pulseless]) and at 40 +/- 1.1 mm Hg (Groups III [pulsatile] and IV [pulseless]). After reperfusion, renal blood flow, hemodynamic power (pressure * flow: hemodynamic power), oxygen consumption (VO2), tissue ATP, and urine output (UO) in Groups I, II, and III were significantly higher than in Group IV (p < .01 by ANOVA). Histopathologic examinations were not significantly different between groups. Under hypotensive conditions, pulsatile perfusion improves hemodynamic power delivery to the organ compared to pulseless perfusion. These results suggest that a pulseless pump is acceptable as an assist device when normal flow or perfusion pressure is maintained.

Animals↗

The vasoregulatory role of endothelium derived nitric oxide during pulsatile cardiopulmonary bypass.

The role of pulsatile flow as a physiologic stimulus for endothelium mediated vasoregulation is poorly understood. Furthermore, non pulsatile flow, which is associated with increased vascular resistance and end-organ failure, has been demonstrated to lead to a decrease in nitric oxide (NO) production in vitro. Anesthetized pigs (23.4 +/- 0.3 kg) were placed on cardiopulmonary bypass using either non pulsatile or pulsatile perfusion for 60 min. In both groups, animals were maintained with a constant mean aortic flow (1.0-1.3 L/min). Serum samples obtained during bypass were assayed for the stable end-products of NO (nitrate [NO3-] and nitrite [NO2-]) by a method based on the Greiss reaction. Systemic vascular resistance was higher after 60 min in the non pulsatile (3712.5 +/- 481.2 dyne sec cm(-5)) vs the pulsatile group (2672.6 +/- 427.0 dyne sec cm(-5)), but not statistically significant (p > .05). However, NO production was decreased in the non pulsatile flow group (27 +/- 6%) vs the pulsatile flow group (14 +/- 5%) at a statistically significant level (p < .005). The results suggest that non pulsatile flow is associated with diminished endothelial shear stress and a reduction in endothelial nitric oxide production. This may contribute to the detrimental physiologic effects observed in prolonged non pulsatile flow states.

Animals↗