PubMed Health⌕ Search

Biomedical subjects

R L Morin

Publications and source records attributed to R L Morin.

At least 37 records · Page 2Linked to original sources

Multiplanar quantitative computed tomography for bone mineral analysis in dogs.

The purpose of this study was to determine the precision and accuracy of quantitative computed tomography bone mineral analysis in dogs in coronally reconstructed images. Nonhomogeneous tissues, such as bones with fractures or deformities, may be better analyzed if multiplanar reconstruction of the transaxial data could be performed without degradation of information. Our analysis demonstrated that coronal reconstruction of quantitative-computed tomography data was precise (1.2 to 4.7%) and accurate (1.3 to 7.5%) in vitro. The technique displays high-quality images, which can be analyzed at any location within the volume scanned. Quantitative computed tomography of canine osteotomy healing in vivo accurately determined bone mineral density of selected regions of interest. Bone mineral density correlated highly with calcium content of the tissue (R2 = 0.76, P less than 0.0001).

Animals↗

Quantification of bone healing. Comparison of QCT, SPA, MRI, and DEXA in dog osteotomies.

Four noninvasive imaging modalities were used to quantitatively evaluate and compare tibial osteotomy healing in dogs. Quantitative computed tomography (QCT), magnetic resonance imaging (MRI), single-photon absorptiometry (SPA), and dual-energy x-ray absorptiometry (DEXA) were the four techniques examined. Bilateral tibial osteotomies were performed in 32 dogs divided into four groups. The osteotomies were stabilized with a 2-mm gap using unilateral external skeletal fixation. Dogs were anesthetized, imaged with the four noninvasive techniques, and killed at 2-12 weeks. Invasive techniques were used to determine: 1) the torsional properties of the bone; and 2) the local stiffness properties and calcium content within the bone. The techniques which had the strongest associations with the torsional properties of the osteotomies were QCT, SPA and DEXA. Generally, QCT and SPA had marginally stronger correlations than DEXA; but, overall, there were no differences between the techniques. MRI had the poorest associations with the torsional properties of the osteotomies. Generally, QCT had the strongest correlations with local material properties, such as indentation stiffness and calcium content. SPA had the second strongest correlations with calcium content and had the third strongest correlations with indentation stiffness behind DEXA. DEXA had the third strongest correlations for calcium content. With the exception of some of the correlations with indentation stiffness, MRI had the poorest associations with the local parameters studied.

Absorptiometry, Photon↗

Magnetic resonance imaging phase encoding: a pictorial essay.

A set of MRI images with various degrees of phase encoding were generated from the same raw data set. The resultant pictorial teaching aid is useful in developing an intuitive understanding of the mechanics and principles of phase encoding in two dimensional, Fourier transform magnetic resonance imaging.

Humans↗

Purchasing medical imaging equipment.

This report presents a summary of the steps and factors involved in the purchasing of medical imaging equipment. Although the range of variations in this process is broad, some fundamental common factors are useful to consider before initiating the acquisition process.

Capital Expenditures↗

Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine.

A new x-ray-based (dual-energy x-ray absorptiometry [DEXA]) instrument for measurement of bone mineral in the spine and hips (QDR-1000, Hologic, Inc.) was compared with a commercial dual photon absorptiometry (DPA) instrument that uses a 153Gd source (DP3, Lunar Radiation Corporation). Measurements were made on phantoms and lumbar spines of patients to study accuracy, precision, limitations, and compatibility of results between instruments. Both instruments measure bone mineral of integral bone in terms of area bone density with an entrance exposure of less than 5 mR. For spinal bone mineral measurements, the DEXA instrument had a shorter scanning time and higher resolution images than the DPA system. The DEXA instrument also showed better precision in a spine phantom and reduced influence of thickness for patient measurement. For bone mineral content, accuracy was about equal for both instruments; for measurements of the area of the region of interest, accuracy was better with the DEXA instrument. With both instruments, fat had little effect on bone mineral density in bone phantom studies. Measurements on both instruments were influenced by the location of a bone phantom within the photon beam. Results in patients showed good correlation (r = 0.988) for bone mineral density. Measurements of bone mineral density in patients were consistently lower with the DEXA instrument because of better accuracy in area measurements. The new x-ray-based instrument is a major advance in bone mineral absorptiometry and provides improved, yet less expensive, measurements in research and clinical applications.

Adipose Tissue↗

Hydrophilic-lipophilic balance as predictor of mucus coating with barium sulfate.

In order to improve barium coating of the mucus layer covering the alimentary tract, various surface active substances are added to commercially available contrast media. The action of additives can be expressed in part by their hydrophilic-lipophilic balance (HLB). In an experimental study using human colonic mucus and barium sulfate USP, surfactants of varying HLB (range, 3-11) were used to study the range of HLB resulting in optimal coating. The best coating occurred with an HLB of 7. Quality of coating may be predicted based on knowledge of the HLB of various surface active additives.

Barium Sulfate↗

Surface shield: device to reduce personnel radiation exposure.

A simple device is described that can reduce personnel exposure from scatter radiation by up to 75%. The device consists of an oblong piece of shielding (0.75-mm lead equivalent) that is taped to the side of the patient during percutaneous renal stone removal and other interventional procedures. Contrary to other shields and barriers, this does not interfere with access to the patient. Scatter exposure data from phantom studies are presented and the rationale for surface shielding discussed.

Humans↗

Aerosol penetration ratio: a new index of ventilation.

Superimposition of nuclear medicine scintigrams and standard radiographs provides a unique opportunity for merging functional information intrinsic to nuclear medicine images with the high resolution anatomic detail of radiographs. A newly developed image processing system allows the merging of two separate films of greatly varying sizes to form a single composite image. Subsequent quantitative analysis of the composite image may be performed. Using the superimposition technique, [99mTc]DTPA aerosol ventilation scans (4.5 X 4.5 cm) were superimposed upon chest radiographs (35.6 X 43.2 cm) in 17 cystic fibrosis (CF) patients. Subsequent quantification of the area of nuclear scan ventilation and the radiographic lung area was then performed. A new quantitative radiologic index of ventilation, the aerosol penetration ratio (APR), was defined. Linear correlation of aerosol penetration ratio with residual volume (RV) as percent of total lung capacity (TLC) measured by body plethysmography was good. We conclude that the APR has validity as a physiologic parameter which localized regional excessive residual volume and correlates well with RV/TLC, the "gold standard" pulmonary function index of obstructive airway disease.

Adolescent↗

The significance of electron binding corrections in Monte Carlo photon transport calculations.

Many Monte Carlo simulations ignore coherent scattering events and utilise the Klein-Nishina free electron distribution, rather than the incoherent differential cross-section, for choosing the trajectories of incoherently scattered photons. We assess the accuracy of this model by comparing its results with those of the complete bound electron model (form factor approach), which simulates coherent scattering events, and uses the appropriate bound electron angular scattering distributions. Both analytic and Monte Carlo calculations demonstrate that use of the free electron scattering distributions significantly underestimates the angular distribution of scattered photon energy resulting from low and medium energy photons incident upon carbon, iron, and platinum barriers. In using the free electron approximations to calculate barrier transmission, significant errors occur only for primary photon energies below 100 keV. Implementation of the complete bound electron model reduces the computational efficiency of our Monte Carlo code by only 10-25%.

Electrons↗

Monte Carlo evaluation of the Sievert integral for brachytherapy dosimetry.

The Sievert integral, widely used to compute dose distributions about filtered line sources, assumes that the emitted energy fluence is exponentially attenuated by the filter thickness traversed by the primary photons. To evaluate this approximation, a Monte Carlo simulation was performed realistically modelling the diffusion and energy degradation of primary photons due to coherent, incoherent and photoelectric interactions in the source filter. Estimates of the exposure rate at points near the source were obtained using analytical averaging. Comparison of the two models shows that for 226Ra and 192Ir sources, the Sievert algorithm consistently overestimates the exposure rate per unit activity. However, such errors may be significantly reduced if source intensity is expressed in terms of exposure rate. Computed exposure rate distributions based on exposure rate calibrations are also less sensitive to uncertainties in available spectroscopic data.

Brachytherapy↗

CT-number variability in thoracic geometry.

The use of absolute CT numbers for in vivo tissue characterization is compromised by a number of technical and geometrical factors. A phantom simulating thoracic geometry and containing intrapulmonary "features" was scanned on three CT scanners allowing for assessment of CT-number variations with a wide number of scanning and geometric parameters. It was found that, with thoracic geometry, the absolute CT numbers of intrapulmonary features (e.g., solitary pulmonary nodules) can vary significantly due to a number of CT scanning parameters, such as geometry, CT scanner used, and/or time. Such variations must be taken into account when establishing criteria for characterizing tissue types using CT numbers. However, results show that variations in quantitative behavior with reasonable changes in patient geometry do not preclude meaningful characterization of solitary lung nodules (using CT-number averages) using CT scans for the three CT scanners studied, providing CT-number threshold data are derived from the same model scanner and operating conditions. The use of CT-number patterns within high-density intrapulmonary pathology (e.g., solitary pulmonary nodules) is compromised by the fact that high CT-number patterns were found to be a function of the reconstruction filter used and object size as well as being influenced by details of the surrounding medium.

Humans↗

Removal of streaking artifact in computed tomography.

In transmission computed tomography, relative X-ray attenuation measurements are made at various angles around a patient's body. These input projection data are reconstructed to yield a cross-sectional view of internal structure. If the body section contains material that severely attenuates the X-ray beam (e.g., surgical clips, lead fragments), high-density streaks that obliterate internal structure will be produced in the process of image reconstruction. This loss of diagnostic information renders the scan useless. A technique has been developed that removes this imaging artifact. The approach views the affected projection data as misinformation. These data are assigned new values, and image reconstruction is performed without changing existing computer hardware or software. Projection data for a head section containing a lead fragment were obtained by Monte Carlo simulation. Three methods of obtaining replacement data were examined. A nearest-neighbor pattern recognition technique yielded excellent results.

Humans↗

A pattern recognition method for the removal of streaking artifact in computed tomography.

A new method is presented for the removal of streaking artifact in computed tomography. The method uses a nearest-neighbor pattern recognition technique to redetermine ray sums that intersect the foreign object responsible for the streaking. When the method is applied to the removal of streaking artifact caused by lead in a skull phantom, excellent results are obtained.

Models, Structural↗

A formalism for the assignment of uncertainties to clinical probabilities of hypothyroidism, euthyroidism, and hyperthyroidism.

A formalism for the optimal estimation of the probabilities of hypothyroidism, euthyroidism, and hyperthyroidism is outlined. The scheme provides a means for assigning uncertainties to the estimates. These uncertainties can be used to determine whether or not the difference between two probabilities is statistically significant. Clinical data are utilized to illustrate the method.

Computers↗

Electron dose reduction coefficients for seven radionuclides and cylindrical geometry.

In determining internal radiation absorbed dose it is frequently not possible to assume a uniform distribution of radionuclide in an infinite, homogeneous, absorbing material. When the source-target geometry is such that the target is source-free, special considerations must be given to the dose contributions from electrons, since the conventional assumption of 100% absorption of non-penetrating radiations leads to overestimation of the absorbed dose. The absorbed dose from electrons determined at a point within the source-free region depends upon the depth within it. Electron dose reduction coefficients determined at appropriate distances from the source surface are multiplied by the electron doses determined from the general absorbed dose equation. This method of correcting for source-free regions has been applied to cylindrical and planar geometry, for spinal cord and nerve root dosimetry in cisternography. Utilising published scaled point kernels for mono-energetic electrons, electron dose reduction coefficients have been determined as a function of depth from the source surface for cylindrical source-free regions of radii 0.5, 0.05 cm and infinity, and seven gamma-ray-emitting radionuclides: 51Cr, 67Ga, 99Tcm, 111In, 113Inm, 169Yb and 203Pb. These values may be used in other internal radiation absorbed dose situations, and similar techniques applied to other source-target geometries.

Humans↗

Dosimetry of several DTPA radiopharmaceuticals in cisternography.

Previously published biologic distribution and clearance data for 169Yb-DTPA in cisternography were utilized to obtain effective spinal segment clearance data for six other easily dhelated radionuclides: 99mTc, 113mIn, 111In, 67Ga, 51Cr, and 203Pb. Absorbed radiation doses to the spinal cord and nerve roots were calculated for each radioactive DTPA compound, employing appropriate cylindrical geometry and reduction coeffients for the dose contributions from the electrons of each radionuclide. Doses are maximal at the surface and decrease rapidly with distance from the surface. The relative useful photon flux from each DTPA radiopharmaceutical for approximately the same average absorbed radiation dose to the spinal cord was determined. The results indicate that 111In and 203Pb should be considered as possible radionuclide tags for DTPA cisternographic imaging.

Brain Neoplasms↗