Heterotopic pancreas diagnosed by cannulation and duct study.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R L Protell.
Explore the source record for details and available documents.
The coagulative efficacy of a "high power" argon laser which delivers 6.5 +/- 1.0 w was compared to that of a "low power" argon laser which delivers 1.0 +/- 0.1 w. The wave-guide angle of divergence was 8 degrees. For the high power laser, the distance between the wave-guide tip and the mucosa varied from 1.0 to 1.5 cm with a delivered power density range of 160 to 487 w per cm2. For the low power laser, the distance between the tip and mucosa varied from 0.7 to 1.3 cm with a power density of 35 to 146 w per cm2. Group A consisted of acute experiments in 6 heparinized dogs in which 51 standard-sized acute gastric ulcers extending into the submucosa were made at laparotomy via a large gastrotomy. Ulcer bleeding rates were quantified into three categories of severity. Within each category, ulcers were randomized to high power, low power, or untreated control. All 19 low power-treated ulcers and 16 untreated controls continued bleeding; 13 of 16 high power-treated ulcers stopped bleeding completely. Representative ulcers were examined histologically. Group B consisted of chronic experiments on 31 ulcers in 7 unheparinized dogs. These ulcers were either treated with high power or left as untreated controls. Dogs were killed and the ulcers were examined histologically at 7, 14, and 28 days. Only rarely did the laser injury penetrate into the muscularis externa. There were no perforations. By 14 days, all lesions were covered with normal surface epithelium. These data encourage further development of congruent to 7.0 w argon laser photocoagulation for eventual clinical use in man.
With minimal transmission loss a high power argon laser (10 w) was coupled to a waveguide consisting of a flexible, single, coated, quartz fiber encased in a protective polyethylene tube. This waveguide can be passed down the biopsy channel of any standard fiberoptic endoscope. An aiming light improves accuracy. Safety devices were developed to protect the subject and the operator. Each of 8 heparinized mongrel dogs had three superficial erosions created endoscopically in the fundal gland mucosa by a jet of warm 0.1 N HC1. In each animal two lesions were photocoagulated with the laser and the third was left as a control. The animals were killed at 0, 4, 7, 10, and 14 days, and the erosions were examined histologically. By 14 days all lesions were covered by normal surface epithelium. Parietal and chief cells had returned to untreated erosions at 14 days but not to all lasered lesions. Only rarely did the lasered lesions penetrate through the muscularis mucosae into the submucosa. High power argon laser photocoagulation is now feasible through standard endoscopes. These data are sufficiently promising to encourage further evaluation of laser photocoagulation in a variety of animal models.
An instrument has been developed which creates an experimental model of an acute bleeding gastric ulcer. The diameter and depth of these gastric ulcers are reproducible. The instrument can be used endoscopically or at laparotomy. Using this ulcer model nonsurgical modalities for the treatment of upper gastrointestinal bleeding can be compared in a controlled manner. This standard experimental model may also facilitate comparison of results among different research groups.
Explore the source record for details and available documents.