Evidence for two distinct nonlinear components in the human pattern ERG.

We obtained the electroretinogram (PERG) in three observers to a 4.6 c/deg grating pattern with a sinusoidal luminance profile which was modulated in time simultaneously with two sinusoidal temporal frequencies (f1 and f2), or at a single frequency (either f1 or f2). Input temporal frequency ranged from 2.4 to 7.5 Hz. A pattern modulated in the counterphase mode with a single frequency produces a response containing only even harmonics of that frequency. However, when the pattern is counterphase modulated with both f1 and f2, the PERG contains second order response frequencies corresponding to intermodulation components (sums and differences) between the two fundamental frequencies. Such frequencies do not exist in the stimulus--they can only be generated by nonlinear neural interactions. Our results provide evidence for at least two nonsaturating nonlinear response mechanisms in the human retina.

Adult↗

Differences in pattern visual evoked potential (PVEP) between hemodialysis and peritoneal dialysis patients.

The visual evoked potential was recorded in peritoneal and hemodialysis patients as compared to normal controls. By using the appropriate visual stimulus we were able to disclose specific VEP abnormalities for each of the two dialysis groups. The dissociation found between the latency of N70 and P100 in peritoneal dialysis patients suggests a possible postsynaptic visual abnormality not described previously. The correlation between the high serum aluminum and the P100 latency of peritoneal dialysis patients requires further investigation.

Adult↗

Astigmatism after penetrating keratoplasty using the Krumeich guided trephine system.

BACKGROUND: The use of a suction trephine during penetrating keratoplasty has the potential to reduce trephination errors and astigmatism after suture removal. METHODS: In this study, we evaluated refractive astigmatism after suture removal in 26 eyes that had penetrating keratoplasty for keratoconus using refraction, keratometry, and videokeratography. Group I (11 eyes) had manual trephination with an open disposable blade of both the donor (8.2 mm) and the recipient (8.0 mm). Group II (10 eyes) had manual trephination with an open disposable blade of the donor (8.2 mm) and Krumeich guided trephine system trephination of the recipient (8.0 mm). Group III (5 eyes) had guided trephination of both the donor (8.0 mm) and the recipient (8.0 mm). RESULTS: The guided trephine groups II and III demonstrated statistically significant less refractive cylinder when compared to manual trephination group I (p < .01). The mean keratometric cylinder for group I was 6.50 diopters (D) (range, 1.50 to 9.00 D), for group II was 3.00 D (range, 0.50 to 7.00 D), and for group III was 2.55 D (range, 0 to 4.00 D). CONCLUSION: The Krumeich guided trephine system produced less keratometric astigmatism than manual trephination after penetrating keratoplasty for keratoconus.

Astigmatism↗