PubMed Health⌕ Search

Biomedical subjects

R Lappalainen

Publications and source records attributed to R Lappalainen.

At least 19 recordsLinked to original sources

Effect of human trabecular bone composition on its electrical properties.

Mechanical properties of bone are determined not only by bone mineral density (BMD), but also by tissue trabecular structure and organic composition. Impedance spectroscopy has shown potential to diagnose trabecular bone BMD and strength, however, the relationships between organic composition and electrical and dielectric properties have not been systematically investigated. To investigate these issues organic composition of 26 human trabecular bone samples harvested from the distal femur and proximal tibia was determined and compared with relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor measured at wide range (50 Hz to 5 MHz) of frequencies. A strong linear correlation was found between the relative permittivity at 1.2 MHz and trabecular bone fat content (r = -0.85, p<0.01, n=26). On the other hand, relative permittivity measured at 200 Hz served as a good predictor of water content (r = 0.83). Phase angle, specific impedance and especially conductivity were strongly related to the trabecular bone dry density and water content (|r| > or = 0.69). Variation in bone tissue collagen content was strongly related to the relative permittivity measured at 1.2 MHz (r = 0.64), but only moderately to other parameters. Glycosaminoglycan content showed no significant relations with any investigated electrical parameters. The present study indicates that if the trabecular bone composition is known, the relationships presented in this study could facilitate calculation of current field distribution, e.g. during electrical stimulation of osteogenesis. On the other hand, our results suggest that permittivity measured at low (<1 kHz) or high (>100 kHz) frequencies could be used, e.g. during implant surgery, for prediction of trabecular bone water or fat contents, respectively.

Adipose Tissue↗

Interrelationships between electrical properties and microstructure of human trabecular bone.

Microstructural changes, such as reduction of trabecular thickness and number, are characteristic signs of osteoporosis leading to diminished bone strength. Electrical and dielectric parameters might provide diagnostically valuable information on trabecular bone microstructure not extractable from bone mineral density measurements. In this study, structural properties of human trabecular bone samples (n=26) harvested from the distal femur and proximal tibia were investigated using the computed microtomography (microCT) technique. Quantitative parameters, e.g. structural model index (SMI) or trabecular bone volume fraction (BV/TV), were calculated. In addition, the samples were examined electrically over a wide frequency range (50 Hz-5 MHz) using a two-electrode impedance spectroscopy set-up. Relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor were determined. Significant linear correlations were obtained between the dissipation factor and BV/TV or SMI (|r| 0.70, p<0.01, n=26). Principal component analyses, conducted on electrical and structural parameters, revealed that the high frequency principal component of the dissipation factor was significantly related to SMI (r=0.72, p<0.01, n=26). The linear combination of high and low frequency relative permittivity predicted 73% of the variation in BV/TV. To conclude, electrical and dielectric parameters of trabecular bone, especially relative permittivity and dissipation factor, were significantly and specifically related to a trabecular microstructure as characterized with microCT. The data gathered in this study constitute a useful basis for theoretical and experimental work towards the development of impedance spectroscopy techniques for detection of bone quality in vitro or in special cases of open surgery.

Bone Density↗

Diurnal and weekly rhythms of health-related variables in home recordings for two months.

Several telecare systems for long-term monitoring of the well-being of patients at home have been developed as an aid in healthcare and to reduce hospitalization costs. Most of the systems have been designed to measure only one or two variables. Because well-being is a combination of both psychological and physiological wellness, there is a need to monitor several psychophysiological variables simultaneously in out-of-hospital conditions for a long period. To understand better the variability of patients' wellness-related variables in long-term recordings, the knowledge of the normal variation in health-related variables in healthy people is necessary. In our study, 14 healthy working middle-aged men were studied daily for 24 h and periods of 50 to 79 days. The variables measured were beat-to-beat heart rate, motor activity, blood pressure, body weight, and temperature. At night respiratory frequency, time of movements, amount of quiet sleep, and ballistocardiographic respiratory variation were also measured. Heart rate variability in the waking period was calculated later (standard deviation of the 5 min average of the successive normal to normal beat to beat intervals). Daily self-reported well-being, activities, and consumption of alcohol were monitored by keeping a behavioral diary. After normalizing the physiological data, the diurnal and weekly variability was calculated for each variable. In several variables the most notable diurnal and weekly variability was found between working time and free time. In conclusion, diurnal and weekly rhythms in several wellness-related physiological and psychological variables were identified, depending on working and free-time in healthy middle-aged men.

Adult↗

Expression of ADAM9 (meltrin-gamma) around aseptically loosened total hip replacement implants.

OBJECTIVE: To investigate the involvement of a disintegrin and the metalloproteinase ADAM9 (meltrin-gamma) in the formation of multinuclear giant cells and osteoclasts in aseptic loosening of hip replacement implants. METHODS: We used in situ hybridization, immunohistochemical staining and western blotting of interface membrane surrounding loosened hip implants, macrophage-colony stimulating factor (M-CSF) and receptor activator of nuclear factor kappaB ligand (RANKL) costimulation and polymethyl methacrylate (PMMA) particle stimulation of human monocytes followed by immunofluorescence staining and flow cytometric analysis. RESULTS: Morphometric analysis revealed that the ADAM9+ area in the revision total hip replacement (THR) interface was larger than in primary THR samples (37.6+/-5.1 vs 5.2+/-0.8%, P=0.002). Double immunofluorescence staining showed that CD68+ interface tissue macrophages and multinuclear giant cells were ADAM9+. ADAM9 mRNA containing mononuclear and multinuclear cells was often seen in a close spatial relationship with other ADAM9+ cells. Western blotting disclosed a 50 kDa ADAM9 band in tissue extracts. Upon M-CSF and RANKL costimulation of human monocytes, the ADAM9 staining pattern changed over time and ADAM9+ cells formed bi- and multinuclear cells. Flow cytometry disclosed that cells of the monocyte/macrophage lineage changed from ADAM9-negative cells into strongly positive cells during a 3-day culture. CONCLUSION: ADAM9 is expressed in interface tissues around aseptically loosened THR implants. ADAM9 may play a role as a fusion molecule in the formation of multinuclear giant cells and osteoclasts from mononuclear precursors in diseases characterized by bone tissue destruction.

ADAM Proteins↗

The effect of powder blend and tablet structure on drug release mechanisms of hydrophobic starch acetate matrix tablets.

This study investigates the release mechanism of a hydrophilic drug (caffeine) from hydrophobic matrix tablets composed of starch acetate. Different particle size fractions of starch acetate were mixed with caffeine (22% V/V) to obtain various mixture organisations in the powder, as well as in the final tablet. The organisation of powder mixtures was calculated by the carrier payload of starch acetate particles, while the pore size distributions in tablets were measured by mercury intrusion porosimetry. A carrier payload below 1 indicated the existence of a free starch acetate particle surface, while numbers greater than 1 pointed to a complete occupation of the starch acetate particle surface area by caffeine particles. The carrier payload calculations gave a good prediction for the existence of a starch acetate matrix in the tablet structures. Caffeine matrices in tablets compressed from the mixtures could be detected by mercury intrusion porosimetry measurements. The existence of different matrices, as well as different pore networks, determined the physical changes of the tablets and the release mechanism of caffeine during dissolution tests. When a tablet contained only a caffeine matrix, rapid tablet disintegration and immediate release of the total amount of caffeine occurred. A single matrix of starch acetate resulted in tablets that remained intact, although cracks were formed. The co-existence of matrices of both materials created surface erosion of the tablet. The caffeine release profiles of tablets that remained intact or showed erosion were fitted by an equation containing both diffusional and relaxational factors to describe the effect of tablet porosity on drug release.

Caffeine↗

Interaction of mobile phones with superficial passive metallic implants.

The dosimetry of exposure to radiofrequency (RF) electromagnetic (EM) fields of mobile phones is generally based on the specific absorption rate (SAR, W kg(-1)), which is the electromagnetic energy absorbed in the tissues per unit mass and time. In this study, numerical methods and modelling were used to estimate the effect of a passive, metallic (conducting) superficial implant on a mobile phone EM field and especially its absorption in tissues in the near field. Two basic implant models were studied: metallic pins and rings in the surface layers of the human body near the mobile phone. The aim was to find out 'the worst case scenario' with respect to energy absorption by varying different parameters such as implant location, orientation, size and adjacent tissues. Modelling and electromagnetic field calculations were carried out using commercial SEMCAD software based on the FDTD (finite difference time domain) method. The mobile phone was a 900 MHz or 1800 MHz generic phone with a quarter wave monopole antenna. A cylindrical tissue phantom models different curved sections of the human body such as limbs or a head. All the parameters studied (implant size, orientation, location, adjacent tissues and signal frequency) had a major effect on the SAR distribution and in certain cases high local EM fields arose near the implant. The SAR values increased most when the implant was on the skin and had a resonance length or diameter, i.e. about a third of the wavelength in tissues. The local peak SAR values increased even by a factor of 400-700 due to a pin or a ring. These highest values were reached in a limited volume close to the implant surface in almost all the studied cases. In contrast, without the implant the highest SAR values were generally reached on the skin surface. Mass averaged SAR(1 g) and SAR(10 g) values increased due to the implant even by a factor of 3 and 2, respectively. However, at typical power levels of mobile phones the enhancement is unlikely to be problematic.

Adipose Tissue↗

Prediction of mechanical properties of human trabecular bone by electrical measurements.

In trabecular bone, the interrelationships of electrical and dielectric properties with mechanical characteristics are poorly known. Information on these relations is crucial for evaluation of the diagnostic potential of impedance techniques. In this study, electrical and dielectric properties, i.e. permittivity, conductivity, phase angle, loss factor, specific impedance and dissipation factor of human trabecular bone samples (n=26, harvested from the distal femur and proximal tibia) were characterized in a wide frequency range (50 Hz-5 MHz). Mechanical properties, i.e. Young's modulus, ultimate strength, yield stress, yield strain and resilience of the samples (n=20) were determined by using destructive compressive testing. Subsequently, measurements of electrical and dielectric properties were repeated after mechanical testing. The measurements were also repeated for the control samples (n=6) that were not mechanically tested. Electrical, dielectric or mechanical properties showed no significant differences between the intact femoral and tibial samples. The electrical and dielectric parameters as well as the linear correlations between the dielectric and electrical parameters with mechanical parameters were strongly frequency dependent. At the frequency of 1.2 MHz, the relative permittivity showed the strongest linear correlations with the Young's modulus (r=0.71, p<0.01, n=20) and ultimate strength (r=0.73, p<0.01, n=20). Permittivity and dissipation factor showed statistically significant changes after mechanical testing. Our results suggest that the measurements of low frequency electrical and dielectric properties may provide information on the mechanical status of trabecular bone and, possibly, may even help to diagnose bone microdamage. In the future, these measurement techniques may be further developed for use during open surgery, such as bone grafting or total hip replacement surgery.

Algorithms↗

Proteoglycan and collagen sensitive MRI evaluation of normal and degenerated articular cartilage.

Quantitative magnetic resonance imaging (MRI) techniques have earlier been developed to characterize the structure and composition of articular cartilage. Particularly, Gd-DTPA(2-)-enhanced T1 imaging is sensitive to cartilage proteoglycan content, while T2 relaxation time mapping is indicative of the integrity and arrangement of the collagen network. However, the ability of these techniques to detect early osteoarthrotic changes in cartilage has not been demonstrated. In this study, normal and spontaneously degenerated bovine patellar cartilage samples (n=32) were investigated in vitro using the aforementioned techniques. For reference, mechanical, histological and biochemical properties of the adjacent tissue were determined, and a grading system, the cartilage quality index (CQI), was used to score the structural and functional integrity of each sample. As cartilage degeneration progressed, a statistically significant increase in the superficial T2 (r=0.494, p<0.05) and a decrease in superficial and bulk T1 in the presence of Gd-DTPA(2-) (r=-0.681 and -0.688 (p<0.05), respectively) were observed. Gd-DTPA(2-)-enhanced T1 imaging served as the best predictor of tissue integrity and accounted for about 50% of the variation in CQI. The present results reveal that changes in the quantitative MRI parameters studied are indicative of structural and compositional alterations as well as the mechanical impairment of spontaneously degenerated articular cartilage.

Animals↗

Electrical and dielectric properties of bovine trabecular bone--relationships with mechanical properties and mineral density.

Interrelationships of trabecular bone electrical and dielectric properties with mechanical characteristics and density are poorly known. While electrical stimulation is used for healing fractures, better understanding of these relations has clinical importance. Furthermore, earlier studies have suggested that bone electrical and dielectric properties depend on the bone density and could, therefore, be used to predict bone strength. To clarify these issues, volumetric bone mineral density (BMDvol), electrical and dielectric as well as mechanical properties were determined from 40 cylindrical plugs of bovine trabecular bone. Phase angle, relative permittivity, loss factor and conductivity of wet bovine trabecular bone were correlated with Young's modulus, yield stress, ultimate strength, resilience and BMDvol. The reproducibility of in vitro electrical and dielectric measurements was excellent (standardized coefficient of variation less than 1%, for all parameters), especially at frequencies higher than 1 kHz. Correlations of electrical and dielectric parameters with the bone mechanical properties or density were frequency-dependent. The relative permittivity showed the strongest linear correlations with mechanical parameters (r > 0.547, p < 0.01, n = 40, at 50 kHz) and with BMDvol (r = 0.866, p < 0.01, n = 40, at 50 kHz). In general, linear correlations between relative permittivity and mechanical properties or BMDvol were highest at frequencies over 6 kHz. In addition, a significant site-dependent variation of electrical and dielectric characteristics, mechanical properties and BMDvol was revealed in bovine femur (p < 0.05, Kruskall-Wallis H-test). Based on the present results, we conclude that the measurement of electrical and dielectric properties provides quantitative information that is related to bone quantity and quality.

Animals↗

Ultrasound indentation of normal and spontaneously degenerated bovine articular cartilage.

OBJECTIVE: We have previously developed a handheld ultrasound indentation instrument for the diagnosis of cartilage degeneration. The instrument has been demonstrated to be capable of quantifying mechanical and acoustic properties of enzymatically degraded and normal bovine articular cartilage in vitro and in situ. The aim of this study was to investigate the sensitivity of the instrument to distinguish between normal and spontaneously degenerated (e.g., in osteoarthrosis) articular cartilage in vitro. DESIGN: Thirty articular cartilage samples were prepared from the bovine lateral patellae: 19 patellae with different degenerative stages and 11 patellae with visually normal appearance. Cartilage thickness, stiffness (dynamic modulus) and ultrasound reflection from the cartilage surface were measured with the handheld instrument. Subsequently, biomechanical, histological and biochemical reference measurements were conducted. RESULTS: Reproducibility of the measurements with the ultrasound indentation instrument was good. Standardized coefficient of variation was < or =6.1% for thickness, dynamic modulus and reflection coefficient. Linear correlation between the dynamic modulus, measured with the ultrasound indentation instrument, and the reference dynamic modulus was high (r=0.993, n=30, P<0.05). Ultrasound reflection coefficient, as determined from the cartilage surface, showed high linear correlations (typically r(2)>0.64, n=30, P<0.05) with the cartilage composition and histological or mechanical properties. The instrument was superior compared to visual evaluation in detecting tissue degeneration. CONCLUSION: This study indicates that the ultrasound indentation technique and instrument may significantly improve the early diagnosis of cartilage degeneration. The results revealed that visual evaluation is insensitive for estimating the structural and mechanical properties of articular cartilage at the initial stages of degeneration.

Animals↗

A programme of behaviour modification and nutrition counselling in the treatment of obesity: a randomised 2-y clinical trial.

OBJECTIVE: To compare two group treatment programmes for obese outpatients. Both programmes included behaviour modification, nutrition counselling, very-low-calorie diet (VLCD) and a continuous measuring of metabolic and anthropometrical status, but they differed regarding the treatment intensiveness. The main aim was to study whether intensive treatment gives a larger weight reduction compared with less intensive treatment and what level of input from health care personnel is needed to reach adequate treatment results. DESIGN: A 2-y randomised clinical trial. SUBJECTS: A total of 43 obese subjects aged 24-60 y, BMI 35 kg/m(2) (29-48). INTERVENTION: Two programmes were used. Both were based on group therapy and were supervised by a dietitian and a psychologist. Group 1 received a continuous intensive treatment with planned group meetings every fortnight during the first year and six group meetings the second year. Group 2 had planned group meetings every third month. Anthropometrical and metabolic data were measured every third month in both groups. The VLCD periods were the same. RESULTS: There was no evidence that a more intensive treatment promotes a larger weight reduction. Weight reduction after 1 y: group 1, -7.6 (+/-0.97) kg, BMI -2.6 (+/-0.3) kg/m(2); group 2, -6.4 (+/-1.16) kg, BMI -2.2 (+/-0.4) kg/m(2). Weight reduction after 2 y: group 1, -6.8 (+/-1.4) kg, BMI -2.4 (+/-0.3) kg/m(2); group 2, -8.6 (+/-1.6) kg, BMI -3.0 (+/-0.3) kg/m(2). The dropout rate was 26%. CONCLUSION: There were no significant differences in weight reduction, compliance or dropout rate between the groups and there was no evidence that a more intensive treatment promotes a larger weight reduction. This observation is of value when setting up treatment programmes. To measure the metabolic and anthropometrical status during the treatment and to give continuous feedback to the subjects seem to be important factors for compliance. Both treatment programmes gave highly significant weight reductions in the range of 5-10%, which has been referred to as a realistic goal for the treatment of obese patients.

Adult↗

Apparatus to test insertion and removal torque of bone screws.

This paper describes affordable equipment for testing bone screw torque, corresponding to ASTM standard F543-00 for testing metallic medical bone screws. Correct testing of thin and long bone screws is essential due to screw failures during insertion and removal of the screws. Furthermore, insertion torque is an important factor in predicting fixation strength, screw pull-out force and effects of surface treatment of screws. The capability of the custom-built tester was determined using polytetrafluoroethylene and wood disc samples and bone screws. Bovine cortical bones allowed testing to the failure limit, i.e. the torque increased in long screws to the fracture limit. For 2.7 and 3.5 mm thick self-tapping cortical bone screws, the failure torques were 30-50 per cent higher than the minimum values required by the standard (1.0 and 2.3 N m respectively). The equipment provided reproducible results and fulfilled the ASTM standard very well. Preliminary testing with amorphous diamond coated bone screws showed good durability of the coating and on average 10-15 per cent lower torque values compared with uncoated screws. The equipment can be used to measure insertion and removal torques as described in the standard. Furthermore, it also allows testing of normal screws and bolts.

Animals↗

Reduced serotonin transporter binding in binge eating women.

RATIONALE: There is evidence that abnormalities in brain dopamine, norepinephrine and serotonin metabolism may play an important role in binge eating. Serotonin-active antidepressant drugs have also been found to decrease binge eating. OBJECTIVE: We investigated serotonin transporter binding in obese binge-eating women. Eleven obese binge-eating and seven obese control women participated in the study. The subjects were not taking any medication known to affect serotonin (5-HT) transporters. METHODS: We used single-photon emission tomography (SPECT) with the radioligand 123I-labelled nor-beta-CIT, which specifically labels 5-HT transporters. RESULTS: Obese binge-eating women showed significantly decreased 5-HT transporter binding in the mid-brain compared with obese controls (2.1 +/- 0.5 versus 2.9 +/- 0.5, respectively). CONCLUSIONS: SPECT imaging with a ligand specific for 5-HT transporters can be used to assess altered serotonin transporter binding in the living human brain. The results tentatively suggest that 5-HT transporter binding is decreased in binge-eating women.

Adult↗

TERVA: system for long-term monitoring of wellness at home.

Long-term monitoring of physiological and psychosocial variables in out-hospital conditions would be beneficial for investigating changes in wellness status of an individual or to understand interaction between physiological and behavioral processes. We aimed to design a personal wellness monitoring system (TERVA), which would allow monitoring of wellness-related variables at home for several weeks or even months. The designed TERVA system runs on a laptop computer and interfaces with different measurement devices through a serial interface. Measured variables include beat-to-beat heart rate, motor activity, blood pressure, weight, body temperature, respiration, ballistocardiography, movements, and sleep stages. In addition, self-assessments of daily well-being and activities are stored by keeping a behavioral diary. To test the system, one healthy man used the system for 10 weeks. The system was successfully applied in out-hospital conditions. The success rate of the measurements was 70-91%, depending on the variable under consideration. The pilot study indicated that the recorded data accurately reflected the health status of the subject. The TERVA system provides a method to record and investigate wellness-related data over several weeks, or even months, outside the hospital among subjects capable of using a personal computer. Several applications of the system are discussed.

Diagnosis, Computer-Assisted↗

Acid attack and cathepsin K in bone resorption around total hip replacement prosthesis.

Normal bone remodeling and pathological bone destruction have been considered to be osteoclast-driven. Osteoclasts are able to attach to bare bone surface and produce an acidic subcellular space. This leads to acid dissolution of hydroxyapatite, allowing cathepsin K to degrade the organic type I collagen-rich osteoid matrix under the acidic condition prevailing in Howship lacunae. Using a sting pH electrode, the interface membrane around a loosened total hip replacement prosthesis was found to be acidic. Confocal laser scanning disclosed irregular demineralization of the bone surface in contact with the acidic interface. Cathepsin K, an acidic collagenolytic enzyme, was found in interface tissue macrophages/giant cells and pseudosynovial fluid. Tissue extracts contained high levels of cathepsin K messenger RNA (mRNA) and protein. These observations suggest the presence of an acid- and cathepsin K-driven pathological mechanism of bone resorption, mediated not by osteoclasts in subosteoclastic space, but rather by the uncontrolled activity of macrophages in extracellular space.

Acids↗

Activation of 5-HT2A receptors impairs response control of rats in a five-choice serial reaction time task.

The present experiments investigated the effects of agents acting at serotonin (5-HT)-2 receptors on the performance of rats in a choice serial reaction time (5-CSRT) task in order to examine the role of 5-HT2 receptors in the modulation of attention and response control. The results indicate that DOI, [(+/-)-1-(2,5-dimethoxy-4-iodophenyl)-2-aminopropane hydrochloride; 0.05, 0.1 and 0.2 mg/kg, subcutaneously], a 5-HT(2A/2C) agonist, slightly impaired the choice accuracy of the well performing rats and markedly increased their premature responding. DOI (0.05 and 0.1 mg/kg) had no effect on the latency to collect earned food pellets or to respond correctly, indicating that these lower doses of DOI did not reduce motivation for the food reward in this task. The selective effect of a low dose of DOI (0.1 mg/kg) on premature responding was completely blocked by ketanserin (0.2 mg/kg), a 5-HT2A antagonist, and ritanserin (0.3 mg/kg), a 5-HT(2A/2C) antagonist, but only partially blocked by a high dose of SER082 (1.0 mg/kg), a 5-HT2C antagonist. In contrast to DOI, mCPP, [1-(3-phenyl)piperazine; 0.05 and 0.15 mg/kg], a 5-HT2C agonist, had no effect on choice accuracy or premature responding, but it reduced behavioral activity and/or arousal as indicated by the decreased number of trials completed and increased the probability of omissions. SER082 (1.0 mg/kg) blocked the effects of mCPP on performance. These data suggest that the overactivation of 5-HT2A receptors impairs response control in a 5-CSRT task, whereas the overactivation of 5-HT2C receptors can affect behavioral activity and/or arousal state of the animals for this food rewarded task.

Adrenergic alpha-Antagonists↗

Psychological and physiological characteristics of sweet food "addiction".

OBJECTIVE: Drug addicts in general can be distinguished from nonaddicts by their affective and physiological and craving responses to drug-related cues. The purpose of this study was to examine similar affective, physiological, and behavioral variables in chocolate "addicts" and control subjects. METHODS: Sixteen addicts and 15 control subjects took part in two laboratory experiments in which their heart rate, salivation, and self-reported responses were measured. RESULTS: In the presence of external chocolate cues, chocolate addicts were more aroused, reported greater cravings, experienced more negative affect, and also ate more chocolate than control subjects. Self-report measures on eating attitudes and behavior, body image, and depression confirmed that a relationship exists between "chocolate addiction" and problem eating. Chocolate addicts showed more aberrant eating behaviors and attitudes than controls, and were also significantly more depressed. DISCUSSION: Chocolate addicts may be considered to be a parallel with addicts generally, because they differ from controls in craving for chocolate, eating behavior, and psychopathology (in respect of eating and affect).

Adult↗

Physical activity levels and body weight in a nationally representative sample in the European Union.

OBJECTIVES: The main objectives of this pan-European study were: (1) to identify different types of physical activity and the time devoted to them, (2) to assess physical activity/inactivity at work and in leisure time, and (3) to determine self-reported body weight and height. DESIGN AND SUBJECTS: In each member state of the EU, approximately 1000 adults, aged 15 years or more, were selected to participate in an interview-assisted face-to-face questionnaire on physical activity and body weight. In each country, sample selection was quota-controlled to ensure national representativeness. Overall, 15,239 subjects in the EU completed the study. RESULTS: On average in the EU, nearly three-quarters of the population participate in some kind of activity. In general, the highest proportions of participants were found in the Nordic countries and the lowest in the southern ones. At the European level, the five most common activities include walking, gardening, cycling, keep fit and swimming. Higher participation rates were found among men, younger subjects and those with a higher level of education. The majority of Europeans fall within the normal body mass index (BMI) range but more than one-third are overweight (31%) or obese (10%) and 11% have a BMI below 20. CONCLUSIONS: Several risk groups related to physical activity emerge from this survey: women, those with a lower level of education, older subjects, the overweight/obese and the underweight. Programmes to promote physical activity need to be tailored to the different groups identified in each country/region in order to increase adherence of non-participants and for the maintenance of those already engaged in activities.

Adolescent↗