Cytogenetic applications of high resolution secondary ion imaging microanalysis: detection and mapping of tracer isotopes in human chromosomes.

Analytical imaging by secondary ion mass spectrometry (SIMS) using a state-of-the-art scanning ion microprobe enables the detection and mapping of tracer isotopes in human metaphase chromosomes. The stimulated mitosis of cells cultured in media containing labelled nucleosides, typically 14C-labelled thymidine or adenosine, and BrDU, yields chromosomes that have incorporated the labelled molecule in their constituent DNA. The label is subsequently detected and localized by SIMS imaging. The relative label signal intensities of sister chromatids can be quantified. The occurrence of sister chromatid exchanges (SCE) can be detected. The distribution of specific nucleosides can be directly mapped. This is non-uniform along the chromatids, giving rise to characteristic banding patterns (SIMS bands) that seem to correspond to the well known G- or Q-bands resulting from conventional staining methods. The study of a number of cytogenetic problems is expected to benefit from the use of this new method of approach, similar in principle, but potentially more sensitive and capable of higher spatial resolution than autoradiography.

Bromodeoxyuridine

Alteration in surface ion composition of cultured bone during metabolic, but not respiratory, acidosis.

Acidosis produced by a fall in [HCO3-] (metabolic acidosis, Met) produces greater Ca efflux from cultured bone than that produced by a rise in PCO2 (respiratory acidosis, Resp). To compare the effects of Met and Resp on bone surface ion composition we measured the surface abundance of 40Ca, 23Na, and 39K in cultured bone with a scanning ion microprobe utilizing secondary-ion mass spectrometry. Neonatal mouse calvariae were incubated for 24 h in medium simulating either Met (pH = 7.193 +/- 0.034, [HCO3-] = 15.1 +/- 1.4 meq/l), Resp (pH = 7.153 +/- 0.014, PCO2 = 85.4 +/- 1.2 mmHg) or normal physiological (Ctl; pH = 7.484 +/- 0.009, [HCO3-] = 29.7 +/- 0.7, PCO2 = 39.6 +/- 0.3) conditions. The surface of Ctl at 2-nm depth is rich in Na and K relative to Ca (Na/Ca = 25.6, K/Ca = 12.0, ratios of counts/s of secondary ions). Compared with Ctl, Met produced a sharp fall in both Na/Ca (6.5, P less than 0.01) and K/Ca (4.6, P less than 0.01), whereas Resp did not alter Na/Ca (23.8) or K/Ca (15.0). Ca efflux was greater in Met (873 +/- 54 nmol.bone-1.24 h-1) than in Resp (546 +/- 71 nmol.bone-1.24 h-1, P less than 0.01), which was greater than that in Ctl (315 +/- 49 nmol.bone-1.24 h-1, P less than 0.01 vs. Met and vs. Resp).(ABSTRACT TRUNCATED AT 250 WORDS)

Acidosis

A new eye shield based on an optimized pinhole array.

The new eye shield described here incorporates the principles of a compound array that provides a significant improvement in vision (from hand movements to 20/100 or better) in a nonaccommodative eye, while retaining all other properties (protection, ventilation, reduction of glare) of eye shields used currently. It is recommended for routine use in patients after intraocular surgery and pupillary dilatation.

Eye Protective Devices

Trilobite eyes and the optics of Des Cartes and Huygens.

The thick lenses in the aggregate eyes of a group of trilobites were double structures designed to eliminate spherical aberration. The shape of the optically correcting interface is in accord with constructions by Des Cartes and Huygens and is dictated by a fundamental law of physics. Trilobites may have evolved such sophisticated eye-lenses to maximise optic neurone response in a dimly lit environment.

Adaptation, Physiological

Scanning transmission ion microscope with a field ion source.

Experiments with a low-resolution scanning transmission ion microscope, using hydrogen ions from a field ionization source, indicate that it will be feasible by this approach to aim at high-resolution ion microscopy. Micrographs of unstained biological specimens have been obtained by critical range absorption of a 55 keV hydrogen ion beam at a resolution of 2000 A.

Animals