PubMed Health⌕ Search

Biomedical subjects

R M Aymat

Publications and source records attributed to R M Aymat.

5 recordsLinked to original sources

Influence of residual stenosis in determining restenosis after cutting balloon angioplasty.

The cutting balloon is a new device for coronary angioplasty, which, by the combination of incision and dilatation of the plaque, is believed to minimize arterial wall trauma, the neoproliferative response, and subsequent restenosis. In this study, we sought to determine predictors of the restenosis using this technique. Seventy-seven patients underwent successful coronary angioplasty with cutting balloon alone. In 67 of these patients (87%), we performed a control angiogram at 6-month follow-up. Pre-, post-, and late angiographic results were evaluated by quantitative coronary analysis. Clinical and angiographic variables were correlated with restenosis as a binary variable and a continuous variable (late loss and late minimum luminal diameter). Univariate analysis showed that the immediate postprocedure minimum luminal diameter (MLD) was smaller in the restenotic group (defined as MLD > 50% by quantitative coronary angiography) than in the nonrestenotic group (1.90 +/- 0.47 mm vs. 2.19 +/- 0.56 mm, P < 0.05). In addition, the immediate percentage of stenosis was higher in the restenotic group than in the nonrestenotic group (37% +/- 10% vs. 27% +/- 11%, P < 0. 003). Multivariate analysis identified the immediate postcutting balloon percentage of stenosis as an independent determinant of binary restenosis (P < 0.008). When restenosis was defined as a continuous variable, the immediate postprocedure MLD was an independent predictor of late loss (P < 0.02) and of late MLD (P < 0. 0002). No clinical, preprocedure angiographic, or technical variables tested were associated with restenosis. The degree of postprocedural residual stenosis after cutting balloon angioplasty is predictive of late restenosis.

Adult↗

Expanding subintimal coronary dissection under a stent-covered arterial segment: serial intravascular ultrasound observations.

A patient with an angiographically unrecognized minor coronary dissection in a stent-covered coronary segment in which a type D spiral dissection extended submedially to the distal artery is described. This complication occurred 6 months after stent implantation and was ascribed to injury of the stented vessel wall during an intravascular ultrasound study.

Aortic Dissection↗

[Initial results with the Multi-Link coronary stent].

INTRODUCTION AND OBJECTIVES: The Multi-Link intracoronary stent is a balloon-expandable stainless steel stent with an interconnected ring structure designed to provide a high degree of compressive resistance while preserving longitudinal flexibility. We present the results of our initial experience with the implantation of this stent. PATIENTS AND METHODS: From May 1996 to April 1997, 124 Multi-link stents were implanted in 97 patients. Mean age 62.2 +/- 11 years. All patients included had a coronary artery diameter > 2.7 mm. Clinical presentation includes stable angina in 20, unstable angina in 72, and myocardial infarction in 5 patients. According to the ACC/AHA classification 6 lesions were type A, 72 type B and 19 type C. The implantation of the stent was for "de novo" lesions in 85 patients and for restenosis in 12. Patients were treated after the procedure with a combination of aspirin and ticlopidine, except six of them who received aspirin and acenocumarol. 16 patients were treated additionally with Abciximab. The degree of stenosis was determined by quantitative angiography. RESULTS: The delivery of the stent was successful in all patients. The degree of stenosis before the procedure was 79.6 +/- 13.1%, and after the stent deployment was 17.7 +/- 11.4%. Three patients presented a non-Q-wave myocardial infarction, two patients had a subacute stent thrombosis, one of them died due to heart failure. During a follow-up of 4.7 +/- 2.6 months five patients were readmitted with recurrent angina (4 due to restenosis and one for vessel occlusion) and one patient with heart failure after myocardial infarction died suddenly three weeks after the dilatation. CONCLUSIONS: The Multi-Link stent was implanted successfully in all patients with a low incidence of complications, showing at the follow-up a reduced rate of clinical restenosis.

Coronary Disease↗

[Coronary stent placement for recurrent angina secondary to myocardial bridging].

Myocardial bridging of the epicardic coronary arteries is not an uncommon finding in angiographic or necropsic studies. Patients who have symptoms usually improve with medical treatment. However, in refractory patients a surgical myotomy of overlying myocardium and/or a coronary bypass may be needed. We report two patients with long myocardial bridges in the mid-left anterior descending coronary artery, who had recurrent angina refractory to conventional treatment. In both patients two consecutive coronary stents were successfully implanted. At five and six months follow-up they are asymptomatic and with good exercise tolerance.

Aged↗