PubMed Health⌕ Search

Biomedical subjects

R M Hamilton

Publications and source records attributed to R M Hamilton.

At least 19 recordsLinked to original sources

Health and neuropsychological functioning of dentists exposed to mercury.

OBJECTIVES: A cross sectional survey of dentists in the west of Scotland and unmatched controls was conducted to find the effect of chronic exposure to mercury on health and cognitive functioning. METHODS: 180 dentists were asked to complete a questionnaire that included items on handling of amalgam, symptoms experienced, possible influences on psychomotor function, and the 12 item general health questionnaire. Dentists were asked to complete a dental chart of their own mouths and to give samples of urine, hair, and nails for mercury analysis. Environmental measurements of mercury in dentists' surgeries were made and participants undertook a package of computerised psychomotor tests. 180 control subjects underwent a similar procedure, completing a questionnaire, having their amalgam surfaces counted, giving urine, hair, and nail samples and undergoing the psychomotor test package. RESULTS: Dentists had, on average, urinary mercury concentrations over four times that of control subjects, but all but one dentist had urinary mercury below the Health and Safety Executive health guidance value. Dentists were significantly more likely than control subjects to have had disorders of the kidney and memory disturbance. These symptoms were not significantly associated with urinary mercury concentration. Differences were found between the psychomotor performance of dentists and controls after adjusting for age and sex, but there was no significant association between changes in psychomotor response and mercury concentrations in urine, hair, or nails. CONCLUSIONS: Several differences in health and cognitive functioning between dentists and controls were found. These differences could not be directly attributed to their exposure to mercury. However, as similar health effects are known to be associated with mercury exposure, it would be appropriate to consider a system of health surveillance of dental staff with particular emphasis on symptoms associated with mercury toxicity where there is evidence of high levels of exposure to environmental mercury.

Adult↗

Clinical use of permanent pacemaker for conversion of intraatrial reentry tachycardia in children.

The use of the implanted atrial-based pacemaker to overdrive postsurgical intraatrial reentry tachycardia (IART) was evaluated in a large group of pediatric patients over a 14-year study period. The authors sought to determine the feasibility of this noninvasive technique in the management of this specialized population and to determine factors associated with successful conversion. They examined 128 manual overdrive attempts performed on 22 consecutive patients. There were 10 patients with post-Fontan repair, 7 with post-Mustard/Senning procedure, and 5 with miscellaneous lesion types. The number of IART episodes for overdrive pacing per patient ranged from 1 to 15. The first overdrive pacing attempt was successful in 63% (14/22) of the patients. The mean IART cycle length was 278 +/- 59 ms. The mean pacing rate for effective conversion of IART was 66 +/- 10% faster than the IART rate. By controlling for repeated measures for individual patients, three factors were found to be independently associated with a successful outcome: (1) lesion type other than Fontan surgery (P = 0.007), (2) lack of acceleration of IART with the overdrive attempt (P < 0.001), and (3) patient use of amiodarone with attempt (P = 0.005). There were three procedural complications: two inadvertent overdrive pacing episodes, and one episode of acceleration of IART cycle length and conduction resulting in need for cardioversion. Manual pacemaker overdrive conversion of IART is a useful adjunct in the management of postsurgical IART in the pediatric population and should be considered as an initial treatment option.

Adolescent↗

Reproducibility of a non-invasive real-time measure of cardiac parasympathetic activity.

The NeuroScope is a new device which produces a continuous real-time index of cardiac parasympathetic activity (the CIPA) and accurately measures RR intervals. The reproducibility of the CIPA has not yet been assessed. This study was designed to assess the reproducibility of a 5 minute recording of the CIPA using the NeuroScope and compare it with that of conventional heart rate variability (HRV) measures. 50 subjects (31 male, 19 female) aged 21-77 years were recruited. 11 of these were apparently healthy and 39 were patients with a variety of cardiological problems. Two 5 minute recordings of CIPA and RR intervals for each subject were made with a 2-3 minute break between recordings. The limits of agreement for the CIPA were such that the second estimate was between 72 and 140% of the first estimate, 95% of the time. The limits of agreement for other indices of HRV, namely SDNN, rMSSD, In low-frequency HRV and In high-frequency HRV, were 61-157%, 68-153%, 77-131% and 76-133%. The short-term reproducibility of a 5 minute recording of CIPA is moderate and better than simple time-domain but not frequency-domain measures of HRV.

Aged↗

Within-breath arterial PO2 oscillations in an experimental model of acute respiratory distress syndrome.

Tidal ventilation causes within-breath oscillations in alveolar oxygen concentration, with an amplitude which depends on the prevailing ventilator settings. These alveolar oxygen oscillations are transmitted to arterial oxygen tension, PaO2, but with an amplitude which now depends upon the magnitude of venous admixture or true shunt, QS/QT. We investigated the effect of positive end-expiratory pressure (PEEP) on the amplitude of the PaO2 oscillations, using an atelectasis model of shunt. Blood PaO2 was measured on-line with an intravascular PaO2 sensor, which had a 2-4 s response time (10-90%). The magnitude of the time-varying PaO2 oscillation was titrated against applied PEEP while tidal volume, respiratory rate and inspired oxygen concentration were kept constant. The amplitude of the PaO2 oscillation, delta PaO2, and the mean PaO2 value varied with the level of PEEP applied. At zero PEEP, both the amplitude and the mean were at their lowest values. As PEEP was increased to 1.5 kPa, both delta PaO2 and the mean PaO2 increased to a maximum. Thereafter, the mean PaO2 increased but delta PaO2 decreased. Clear oscillations of PaO2 were seen even at the lowest mean PaO2, 9.5 kPa. Conventional respiratory models of venous admixture predict that these PaO2 oscillations will be reduced by the steep part of the oxyhaemoglobin dissociation curve if a constant pulmonary shunt exists throughout the whole respiratory cycle. The facts that the PaO2 oscillations occurred at all mean PaO2 values and that their amplitude increased with increasing PEEP suggest that QS/QT, in the atelectasis model, varies between end-expiration and end-inspiration, having a much lower value during inspiration than during expiration.

Animals↗

Chronotropic competence of the sinus node in congenital complete heart block.

Electrocardiograms taken at rest of 2 children with transplacental exposure to anti-Ro antibody but 1:1 atrioventricular conduction demonstrated sinus node disease. Treadmill exercise testing of 28 patients with congenital complete heart block found 3 patients with chronotropic incompetence of the sinus node.

Adolescent↗

Investigative methods of congenital complete heart block.

Congenital heart block (CHB) has been described for a century and related to the presence of maternal autoimmune disease for three decades, but little is understood about its mechanism. To explore the pathophysiology of CHB, technologies in both basic and clinical electrophysiology are being developed and applied. Human fetal rhythm is currently inferred from cardiac mechanical events by using fetal ultrasound, allowing for the detection of second and third-degree heart block. Fetal electrocardiography is being explored to assess its feasibility as a clinical tool to detect fetal first-degree block in the mid trimester. Sequential composite digital recordings from the maternal abdomen are made every 4 weeks from pregnancies at risk for congenital heart block. Filtering and averaging techniques are used to enhance the fetal signal. So far, these techniques have produced a fetal QRS complex trigger signal for use in three-dimensional fetal echocardiography. Because the human fetus cannot be studied directly, a Langendorff rabbit model of CHB has been developed. With 5-10 mL of human serum in 150-300 mL of Krebs solution, prolongation of the Wenckebach second-degree atrioventricular block cycle length occurred. This was reproduced by using serum from seven of eight CHB mothers as compared with none of six controls mothers.

Animals↗

Long-term outcome and prognostic determinants in children with hypertrophic cardiomyopathy.

OBJECTIVES: We sought to determine clinical, angiographic, and echocardiographic predictors of survival in children with isolated hypertrophic cardiomyopathy (HCM) in a large pediatric centre. BACKGROUND: Sudden death is a catastrophic outcome of HCM in childhood but has been difficult to predict. Current therapies might provide for improved outcome if factors identifying high risk can be identified. METHODS: Records of 99 patients diagnosed with HCM from 1958 to 1997 at <18 yr were reviewed for clinical, angiographic (n = 62) and echocardiographic (n = 83) predictors of survival outcome. The effects of clinical characteristics on sudden death (including resuscitated sudden death) were individually tested in Cox's proportionate hazard modeling. RESULTS: Seventy-one subjects were male. Median age at diagnosis was 5.0 yr with a medical follow-up interval of 4.8 yr. Thirty-seven of 97 patients had a family history of HCM. Ambulatory electrocardiograms (ECG) in 78 patients demonstrated supraventricular tachycardia in 16 and ventricular tachycardia in 21. Death or resuscitated sudden death occurred in 18 patients. Sudden death rate was 2.7%/yr after age 8 yr. Cox's proportionate survival modeling revealed increased corrected QT interval (QTc) dispersion on ECG (relative risk [RR] 1.61 per 20 ms increment, p < 0.0003), ventricular tachycardia (VT) on ambulatory ECG (RR 3.75, p < 0.006) and myocardial bridging of the LAD coronary (RR 12.0, p < 0.003) to be associated with reduced time to death or resuscitated sudden death. CONCLUSIONS: Detailed assessment of ECGs, ambulatory ECGs, and coronary angiography can assist in identifying which children with HCM are at risk for sudden death.

Adolescent↗

Neonatal atrial flutter: significant early morbidity and excellent long-term prognosis.

Twenty-five neonates (16 boys and 9 girls) who had atrial flutter were identified. Diagnosis was made on or before the first day of life in 18 (72%). Heart failure were present in 9 patients, and hydrops fetalis was present in another 5. Atrial and ventricular rates did not differ between symptomatic and asymptomatic patients. Atrioventricular conduction was variable in 16 patients, and documented 1:1 conduction occurred in 5. Digoxin was the initial drug therapy given to 21 patients, with 7 reverting to sinus rhythm. Electrical cardioversion (pacing or synchronized shock) was attempted in 13 of the 14 cases in which digoxin was not successful and was attempted as the first treatment in 3 cases. Sustained sinus rhythm was achieved in 9. Two infants died of complications from prematurity but without having been successfully converted to sinus rhythm. No patient had atrial flutter during long-term follow-up (median 23 months). Neonatal atrial flutter has significant morbidity but an excellent long-term prognosis.

Anti-Arrhythmia Agents↗

Arrhythmia and mortality after the Mustard procedure: a 30-year single-center experience.

OBJECTIVES: Our purpose was to assess the risk factors for late mortality, loss of sinus rhythm and atrial flutter after the Mustard operation. BACKGROUND: The Mustard operation provides correction of cyanosis with low surgical risk in transposition of the great vessels. However, right ventricular failure, loss of sinus rhythm, atrial flutter and death are frequent long-term complications. METHODS: Records of 534 children who underwent the Mustard operation at a single center since 1962 were reviewed for demographic, anatomic, electrocardiographic and physiologic predictors and outcomes. RESULTS: There were 52 early deaths (9.7%). Survival analysis was undertaken for 478 early survivors with a mean follow-up interval of 11.6 +/- 7.2 years. There were 77 late deaths (16.1%), with sudden death (n = 31) the most frequent cause. Survival estimates were 89% at 5 years and 76% at 20 years of age. Risk factors were an earlier date of operation, operative period arrhythmia and an associated ventricular septal defect. Risk (hazard) of late death declined in the first decade, with further peaks in the second decade. Sinus rhythm was present in 77% at 5 years and 40% at 20 years. Loss of sinus rhythm was associated with previous septectomy, postoperative bradycardia and late atrial flutter. Freedom from atrial flutter was 92% at 5 years and 73% at 20 years of age. Risk factors for atrial flutter were the occurrence of perioperative bradyarrhythmia, reoperation and loss of sinus rhythm during follow-up. Risk of atrial flutter demonstrates a late increase. CONCLUSIONS: Ongoing loss of sinus rhythm and late peaks in the risk of atrial flutter and death necessitate continued follow-up.

Arrhythmias, Cardiac↗

Risk factors for venous obstruction in children with transvenous pacing leads.

To determine the incidence and risk factors for venous obstruction in children with transvenous pacing leads, 63 children were evaluated clinically and echocardiographically. Patients with abnormal clinical and/or echocardiographic findings were further investigated by venography. Thirteen patients (21%) had evidence of venous obstruction. Venography in 11 (2 refused) showed that severity of obstruction (as defined by percentage of luminal narrowing) was complete (100%) in 3, severe (> 90%) in 4, and moderate (60%-90%) in 5 (1 patient having 2 sites of obstruction). Risk factors for obstruction in 55 patients with single implantation procedures (10 with obstruction; 18%) were sought. Total cross-sectional area of lead(s) was indexed to body surface area at implantation (INDEX). Patients with obstruction had a higher mean INDEX (7.6 +/- 1.6 mm2/m2) than patients without obstruction (4.9 +/- 2.0 mm2/m2); P < 0.0002). Receiver-operator characteristic curves showed an INDEX > 6.6 mm2/m2 to best predict obstruction, with a sensitivity of 90% and specificity of 84%. Since pacing is lifelong, sizing of transvenous leads to the child is important to prevent obstruction and preserve venous access.

Adolescent↗

A comparison of two stab-on unipolar epicardial pacing leads in children.

The Oscor MP52V and Medtronic 4951 leads have similar construction and intended application. To determine if one of these designs was more suited to pediatric pacing, we reviewed implant, 3 month, and 12 months follow-up thresholds for all 18 MP52V implants at our institution from December 1989 to April 1991 and compared them to the 4951 implants from January 1982 to October 1989. Lead survival for the MP52V implants was compared to the most recent 36 4951 implants. Patients ranged in ages from 2 days-16 years (median = 4 years) and required antibradycardia pacing for congenital or acquired heart disease. Patients were compared for weight and proportion of atrial leads in each group by t-test and Fisher exact tests respectively. Energy thresholds were assessed in microJ and compared by t-test. Lead survival was defined by abandonment or replacement for any reason. Kaplan & Meier survival curves were plotted and compared by Gehan's Wilcoxan Test. There were no significant differences between the MP52V and 4951 groups for age at implant (53 months vs 80 months) or proportion of atrial implants (5/18 vs 11/36). Lead survival was poor but did not differ significantly (70% vs 78% cumulative survival at 3 years), usually failing by exit block. Implant and follow-up thresholds did not differ significantly between leads. The MP52V did not provide significant improvement in performance over the 4951. New epicardial lead designs are needed to improve lead survival and thresholds in children.

Adolescent↗

Impact of programmed sensitivity safety factor on atrial sensing in children.

The relationship between the pacemaker sensitivity safety factor (PSSF) and atrial under- or oversensing as documented by 24-hour Holter monitoring was examined. Our study comprised 78 transvenous fixed atrial leads implanted between 1983-1995 in 71 children. Overall, 210 Holter reports identified 143 (68%) Holters with normal atrial sensing function, 31 (15%) with undersensing, 32 (15%) with oversensing, and 4 (2%) with both problems. From 161 Holter reports in which the PSSF was available, the incidence of undersensing at a PSSF of 2.0 (range 1.5-2.4) was 25% (14/57). There was a dramatic decline in undersensing when the PSSF was > or = 3 (3%) compared to a PSSF < 3 (21%) (P < 0.001). A PSSF cut-off point of 2.0 best predicted occurrence of undersensing with a sensitivity of 79% and a specificity of 67%. Other variable were also examined by multiple logistic regression analysis, but only PSSF remained highly associated with undersensing (odds ratio [OR] = 0.6, P = 0.03). In contrast, PSSF did not have a significant role in predicting oversensing, but presence of sick sinus syndrome (OR = 10.5) or unipolar lead (OR = 5.6) were significantly associated with oversensing (P = 0.0001). The majority of undersensing problems can be avoided by routinely allowing for at least a threefold or more programmed sensitivity margin. Other factors may increase the risk of oversensing, regardless of the PSSF.

Child↗

Alveolar and dead space volume measured by oscillations of inspired oxygen in awake adults.

Forced sinusoidal oscillations in the inspired concentration of a low-solubility inert gas can be used to measure airways dead space and alveolar volume. When inspired oxygen is oscillated about its mean value in the same way, the ratio between the amplitudes of the resulting end-expired and inspired oxygen oscillations is the same as that of an inert gas such as argon. Thus, oxygen forcing oscillations can be used to measure lung volume. In nine healthy spontaneously breathing adults, the FIO2 (mean FIO2 = 0.26, mean minute volume = 8.5 L/min) was forced to sinusoidally oscillate with an amplitude of +/- 0.04. The mean airways dead space measured using FIO2 oscillations with a forcing period of 3 min was 0.17 +/- 0.04 L, and the airways dead space measured by a single-breath C02 technique was no different at 0.19 +/- 0.03 L. An oxygen oscillation of the same period measured the mean end-expired alveolar volume at 3.1 +/- 0.7 L. Adding together the airways dead space and end-expired alveolar volume, obtained by the oxygen oscillation technique, provided a measure of FRC that at 3.3 +/- 0.7 L matched the FRC of 3.3 +/- 0.8 L measured by whole-body plethysmography. A third measure of FRC using a multiple-breath nitrogen washout technique gave a smaller volume of 3.00 +/- 0.85 L. The advantage of using FIO2 oscillations is that accurate FRC measurements can be made continuously, without interfering with the subject's natural breathing rhythm.

Adult↗

Five-year experience with implantable defibrillators in children.

Cardioverter-defibrillators were implanted in children aged 4 to 16 years over a 5-year period with no mortality and eventual clinically appropriate shocks in 6 of 11 patients. Both transvenous and epicardial implantable cardioverter-defibrillators were safe and effective in children resuscitated from sudden death or at high risk for sudden death.

Adolescent↗

Clinical spectrum, therapeutic management, and follow-up of ventricular tachycardia in infants and young children.

We reviewed 40 infants and young children with VT. Median maximum VT rate was 214 beats/min (range 152 to 375 beats/min). A cause was defined in 20 (50%), the most common being cardiomyopathy or myocarditis in 8 (20%). There were six deaths (15%) related to VT, three of which occurred at diagnosis and in patients less than 1 week old. In 5 of 6 deaths related to VT, a cause was defined. At follow-up, 31 (91%) of 34 survivors did not have VT. The presence of symptoms was a predictor of death related to VT. The outlook for asymptomatic patients and those who survived more than 6 months after diagnosis and who do not have progressive myocardial disease appears good.

Actuarial Analysis↗