PubMed Health⌕ Search

Biomedical subjects

R M Jose

Publications and source records attributed to R M Jose.

6 recordsLinked to original sources

Patient satisfaction following abdominoplasty: an NHS experience.

Abdominoplasty is one of the few cosmetic procedures performed in the UK on the National Health Service (NHS). In the current climate of tight resource rationing many primary care trusts (PCTs) are refusing to fund such operations, resulting in a number being carried out in the independent sector. There are very few studies in the literature on patient satisfaction following abdominoplasty, with none from the UK. Our study aimed to look at the patient satisfaction rate following abdominoplasty in the NHS and study further the areas of dissatisfaction. A questionnaire survey was sent to 153 patients who underwent the procedure over a 5-year period. Replies were received from 118 (78%) patients, revealing a 77% satisfaction rate amongst responders. Further analysis of the dissatisfied patients revealed particular dissatisfaction with dog-ears, residual abdominal overhang and issues relating to the scar. The dissatisfied group was exclusively female from across the age spectrum, although analysis showed an increase in dissatisfaction with time, with the highest levels seen at 4-6 years post-abdominoplasty. This study has identified a number of areas of patient dissatisfaction, even in carefully selected patients.

Abdomen↗

A spontaneous compartment syndrome in a patient with diabetes.

A compartment syndrome is an orthopaedic emergency which can result from a variety of causes, the most common being trauma. Rarely, it can develop spontaneously and several aetiologies for spontaneous compartment syndrome have been described. We describe a patient with diabetes who developed a spontaneous compartment syndrome. The diagnosis was delayed because of the atypical presentation.

Anterior Compartment Syndrome↗

Effect of optic size on posterior capsule opacification: 5.5 mm versus 6.0 mm AcrySof intraocular lenses.

PURPOSE: To determine the effect of intraocular lens (IOL) optic diameter on posterior capsule opacification (PCO) using digital retroillumination images. SETTING: Eye Department, St. Thomas' Hospital, London, United Kingdom. METHODS: In this prospective study, 60 patients with senile cataract had routine phacoemulsification by a single surgeon and received standardized medication. The patients were divided into 2 equal groups. The first group received a 5.5 mm 3-piece AcrySof IOL (MA30BM, Alcon) inserted in the bag. The second group received a 6.0 mm 3-piece AcrySof IOL (MA60BM, Alcon). Retroillumination images were obtained 1, 30, 90, 180, and 360 days postoperatively. The percentage area of PCO was calculated objectively by dedicated software at 90, 180, and 360 days. At 1 day, the degree of capsulorhexis-IOL contact was determined by inspecting the images. RESULTS: Throughout the follow-up, there was less PCO in the 6.0 mm optic group than in the 5.5 mm optic group, and the difference reached significance 1 year postoperatively (P =.0017). At 1 year, the median percentage of PCO was 1.5% (95% confidence interval [CI] 1.4-5.3) in the 6.0 mm group and 6.9% (95% CI 5.8-18.0) in the 5.5 mm group. CONCLUSIONS: A larger IOL optic diameter was associated with less PCO.

Acrylic Resins↗

A control systems approach for the simulation of renal dynamic software phantoms for nuclear medicine.

For renal dynamic studies, the COST B2 hybrid phantom is an example of an artificially created software phantom. Although this phantom is useful, it is not possible to implement the phantom in a self-consistent fashion to produce, for example, a collection of tracer in the bladder which is related to the flow from the kidneys. In this study control systems are used to provide a self-consistent model. A feed-forward control system was designed for the transport of DTPA in the human body using SIMULINK. The system is based on a three-compartment model described by a set of differential equations with flow rates which may be set by the operator. The differential uptake in the kidneys may also be specified, while the flow of tracer through the renal parenchyma and collecting system of each kidney is determined using two-parameter retention functions. Curves corresponding to normal or pathological conditions may be simulated for plasma, parenchyma, collecting system and bladder by appropriate selection of parameters. The system is user-friendly and can be used to simulate almost all conditions seen in patient studies. The next stage of using this information to design dynamic image simulations is in progress.

Computer Simulation↗