R M Lu

Publications and source records attributed to R M Lu.

7 recordsLinked to original sources

Radiopotentiation of human brain tumor cells by sodium phenylacetate.

Phenylacetate (PA) inhibits the growth of tumor cells in vitro and in vivo and shows promise as a relatively nontoxic agent for cancer treatment. A recent report shows that prolonged exposure of cells to low concentrations of PA can enhance the radiation response of brain tumor cells in vitro, opening up the possibility of using this drug to improve the radiation therapy of brain tumor patients. We investigated the cytotoxicity produced by sodium phenylacetate (NaPA) alone and in combination with X-rays in SF-767 human glioblastoma cells and in two medulloblastoma cell lines, Masden and Daoy. Exposure of all three cell lines to relatively low concentrations of NaPA for up to 5 days did not enhance the subsequent cell killing produced by X-irradiation. However, enhanced cell killing was achieved by exposing either oxic or hypoxic cells to relatively high drug concentrations ( > 50-70 mM) for 1 h immediately before X-irradiation. Because central nervous system toxicity can occur in humans at serum concentrations of approximately 6 mM PA, translation of these results into clinical trials will likely require local drug-delivery strategies to achieve drug concentrations that can enhance the radiation response. The safety of such an approach with this drug has not been demonstrated.

Brain Neoplasms↗

Clinical significance of a new P wave lead vector for pacemaker follow-up of atrial functions.

Patient welfare requires routine follow-up procedures of implantable pacemakers. However, the assessment of atrial sensing and pacing functions in implantable pacemakers is often a challenge due to difficult identification of low amplitude P waves on surface electrocardiograms (ECGs). A previous body surface mapping study suggested that a novel P wave lead vector (P lead) had larger root mean square values than other standard leads. However, for pacemaker follow-up procedures, peak-to-peak amplitudes are more relevant than root mean square values. In this study, the peak-to-peak amplitudes of intrinsic and paced P waves recorded from surface ECG standard lead II and the P lead were compared. In addition, intrinsic and paced R waves were also compared. Data recorded from 15 patients undergoing electrophysiological studies indicated that peak-to-peak amplitudes of the P lead were significantly larger than standard lead II: 24% for intrinsic P waves, 30% for paced P waves, and 72% for intrinsic R waves. In addition, the P lead amplitude of paced R waves showed a nonsignificant increase of 24% compared with standard lead II. Therefore, the use of this new lead vector may improve the clinical ease-of-use and reduce the time required for follow-up procedures of implantable pacemakers for atrial sensing and pacing assessments.

Atrial Function↗

Ventricular fibrillation detection using the evoked electrogram from the braided endocardial defibrillation lead.

Life-threatening consequences can be the result of inappropriate classification of ventricular fibrillation for patients with implantable cardioverter defibrillators. The objective of this study was to determine if analysis of the asynchronously paced evoked electrogram using the braided endocardial defibrillation lead could improve the detection of ventricular fibrillation. The depolarization portion of the evoked electrogram was integrated to obtain the paced depolarization integral. The results demonstrated that the mean of the paced depolarization integral, its SD, and the mean +/- SD were significantly different between sinus rhythm and ventricular fibrillation (p < 0.005, p < 0.05, p < 0.01, respectively). These results suggest that the paced depolarization integral obtained with the braided endocardial defibrillation lead could improve the specificity and sensitivity of ventricular fibrillation detection.

Animals↗

The measurement of the paced depolarization integral using the braided endocardial lead.

Previous studies have shown that the paced depolarization integral (PDI) data recorded in unipolar configuration could potentially improve the specificity of tachyarrhythmia classification in an implantable cardioverter defibrillator (ICD). However, the defibrillation protection would be compromised if the ICD case were used as an indifferent electrode. Since transvenous defibrillation leads are being investigated to be used with ICDs, this study determined if reliable PDI data could be obtained using the braided endocardial defibrillation lead (BEDL). The results demonstrated that comparable PDI values and PDI changes with epinephrine induced sinus tachycardia were obtained with all three tested sensing configurations: conventional unipolar, tip electrode to right ventricular defibrillation electrode, and tip electrode to superior vena cava defibrillation electrode. Therefore, the BEDL can be used to measure PDI data, which possibly may improve tachyarrhythmia classification in an ICD, without compromising its defibrillation protection.

Animals↗

Evaluation of Mycotrim-GU for isolation of Mycoplasma species and Ureaplasma urealyticum.

The Mycotrim-GU (Hana Biologics, Berkeley, Calif.) biphasic culture system and a conventional system were compared for their ability to detect Ureaplasma urealyticum and Mycoplasma species in 100 clinical specimens. Both systems detected 18 Mycoplasma spp. isolates. The average colony detection time was 1.9 days with the Mycotrim-GU and 2.3 days with the conventional system. The Mycotrim-GU agar detected all 33 U. urealyticum isolates recovered in the study, and the conventional agar detected 31. In addition to the U. urealyticum isolates recovered from the agar, there were several specimens that, although they did not grow colonies on the agar, gave an alkaline broth change. Of these specimens, two were found with the conventional system and seven were found with the Mycotrim-GU. The average detection time of U. urealyticum colonies was 2.0 days for the conventional agar and 1.7 days for the Mycotrim-GU. The Mycotrim-GU offers several advantages over the conventional system: it is commercially available, consists of a one-flask system which is ready to use, has a significantly longer shelf life, and is cost competitive. This study showed the Mycotrim-GU to be an effective system for detecting the genital mycoplasmas.

Culture Media↗

A simple digital filter to remove line-frequency noise in implantable pulse generators.

This study investigated computer simulations and animal studies of a simple digital notch filter to remove 50-and 60-Hz line-frequency-noise interference. The digital notch filter was achieved by computing running subtraction of the intracardiac electrogram and the electrogram recorded one notch-sample period previously. Simultaneous rejection of the two worldwide line frequencies was obtained by computation of the minimum of two separate notch-filter outputs. Power consumption of this numerical algorithm was reduced for applications in implantable devices by operating the notch filters only from 20 msec to 50 msec after a sense event. A sense event was classified as a noise sense if the sum of notch-filter output during this window was less than a preset threshold of the sum of the raw data during the same time window. Otherwise, the sense event was classified as a true sense. The computer simulations determined an optimum threshold value of 33%. The filter was tested in five animal studies using a signal generator to inject additive noise interference. The results indicated that this simple filter could be implemented in an implantable pulse generator and could effectively exclude incorrect line-frequency-noise senses at the notched frequencies.

Algorithms↗