Stir bar sorptive extraction and large volume injection gas chromatography to determine a group of endocrine disrupters in water samples.

Stir bar sorptive extraction (SBSE) combined with gas chromatography (GC) with mass spectrometric detection (MS) has been applied to determine a group of suspected endocrine disrupters in water samples. One centimeter stir bars coated with PDMS were used to extract the analytes and then solvent desorption was carried out. The absorption and desorption parameters in SBSE were optimized and large volume injection was used with a programmed temperature vaporizer injector (PTV) in GC to enhance the sensitivity of the method. The linear range of some endocrine disrupters was between 0.05 and 5 microg l(-1) and limits of detection were 0.01-0.24 microg l(-1) under full scan acquisition mode. The repeatability and reproducibility of the method (n = 5) for Ebro river water samples spiked at a level of 0.5 microg l(-1) was below 13 and 23%, respectively. Recoveries between 42 and 96% were obtained with the exception of atrazine. The method was applied to analyze real water samples from the Ebro River and irrigation streams of Ebro Delta and some of the compounds studied (aldrin, dieldrin, 4,4'-DDE and 4,4'-DDT) were found in some of them between detection and quantification limits.

Chromatography, Gas↗

Determination of endocrine-disrupting compounds in water samples by on-line solid-phase extraction-programmed-temperature vaporisation-gas chromatography-mass spectrometry.

We developed an automated on-line solid-phase extraction (SPE)-gas chromatography-mass spectrometry method to determine a group of endocrine disruptors in water samples. The interface device used for connecting SPE with GC was a programmed-temperature vaporiser (PTV) whose liner was packed with Tenax. We optimized the parameters that affected both SPE and PTV working in solvent vent mode. The performance of the method was tested with several environmental water samples. The limits of detection of the method were between 0.001 and 0.036 microg l(-1) under full-scan acquisition mode. We determined phthalates and adipate in all real samples at concentrations between 0.11 and 8.10 microg l(-1). Atrazine and p,p'-DDE were also found in an irrigation stream water sample at 0.16 and 0.04 microg l(-1), respectively.

Endocrine Glands↗

Method based on solid-phase microextraction--high-performance liquid chromatography with UV and electrochemical detection to determine estrogenic compounds in water samples.

We determined a group of estrogenic compounds by solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) with both ultraviolet (UV) and electrochemical detection (ED). A modified liquid chromatograph was used. Polyacrylate fibers (85 microns) were used to extract the analytes from the aqueous samples. Dynamic and static modes of desorption were compared and the variables affecting both absorption and desorption processes in SPME-HPLC were optimized. Static desorption gave the best recoveries and peak shapes. The performance of the SPME-HPLC-UV-ED method was checked with river water and wastewater. The method enabled estrogenic compounds to be determined at low-microgram l-1 levels in real water samples. Limits of detection were between 0.3 and 1.1 micrograms l-1 using UV detection and between 0.06 and 0.08 microgram l-1 using ED. beta-Estradiol was found in samples from a wastewater treatment plant at concentrations between 1.9 and 2.2 micrograms l-1.

Chromatography, High Pressure Liquid↗

Application of on-line solid-phase extraction-gas chromatography-mass spectrometry to the determination of endocrine disruptors in water samples.

We have applied a method based on solid-phase extraction (SPE), on-line coupled to gas chromatography-mass spectrometry through an on-column interface, to determine a group of endocrine-disrupting compounds in water samples. We have optimised the parameters affecting the SPE process and transfer step and used the method to analyse river, coastal and tap waters. In the full-scan acquisition mode, all the compounds were determined by preconcentrating only 15 ml of water sample. Di-n-butyl phthalate, benzylbutyl phthalate, bis(2-ethylhexyl) phthalate and bis(2-ethylhexyl) adipate at concentrations between 0.02 and 0.5 microg l(-1) were determined in some real samples.

Endocrine Glands↗

Determination of polycyclic aromatic hydrocarbons and polycylic aromatic sulfur heterocycles by high-performance liquid chromatography with fluorescence and atmospheric pressure chemical ionization mass spectrometry detection in seawater and sediment samples.

Two methods for determining 10 polycyclic aromatic compounds were developed. Both methods were based on high-performance liquid chromatography (HPLC), but one method used fluorescence detection, while the other used atmospheric pressure chemical ionization mass spectrometry (APCI-MS). For water analysis, solid-phase extraction (SPE) was on-line coupled to the separation system. Using a styrene-divinylbenzene copolymer (PLRP-s) as sorbent in the SPE and adding 20% of acetonitrile to the water sample before its preconcentration, recoveries were above 70% for most of the compounds. For the fluorescence method, all compounds were detected and six of them could be quantified at concentrations higher than 0.02 microg 1(-1). For the MS detection method, only seven of the compounds were detected and six were quantified at concentrations higher than 0.06 microg 1(-1). To analyse sediment samples, an extraction with dichloromethane was used and, due to the complexity of the matrix, a standard addition calibration was carried out. Seawater and sediment samples taken from the Tarragona fishing port and marina on the coast of Catalonia (Spain) were analysed, and five compounds (benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, benzo[ghi]perylene and indeno[1,2,3-cd]pyrene) were quantified in the sediment samples.

Atmospheric Pressure↗

Solid-phase microextraction coupled to high-performance liquid chromatography to determine phenolic compounds in water samples.

Solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) with ultraviolet (UV) and electrochemical detection (ED) has been applied to determine 11 phenolic compounds considered priority pollutants by the US Environmental Protection Agency. 85 microm polyacrylate fibers were used to extract the analytes from the aqueous samples. Two different designs of the liquid chromatograph were compared in combination with SPME. Dynamic and static modes of desorption in both HPLC designs were compared and the variables affecting both absorption and desorption processes in SPME-HPLC were optimized. Static desorption in both HPLC systems showed better recoveries for the phenolic compounds. The performance of the SPME-HPLC-UV-ED method was evaluated with river water and wastewater samples. The method enabled the determination of phenolic compounds at low levels in these water samples.

Chromatography, High Pressure Liquid↗

Comparison of different fibers for the solid-phase microextraction of phthalate esters from water.

Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been applied to determine six phthalate esters and one adipate ester in water. The SPME parameters were optimized for several commercially available fibers. A 65-microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) was the fiber selected and was applied to analysis of water from the Ebro river and the industrial port of Tarragona. The studied compounds were found at concentrations ranging from 0.4 microg l(-1) for di-n-butyl phthalate ester (DnBP) to 3.2 microg l(-1) for bis(2-ethylhexyl) phthalate ester (DEHP). The linear range for real samples was from 0.1 to 10 microg l(-1) for most phthalates, and the limits of detection of the method were between 3 and 30 ng l(-1). Repeatability and reproducibility between days (n = 5) for 1 microg l(-1) samples were below 13 and 18%, respectively.

Dibutyl Phthalate↗

Monitoring of antifouling agents in water samples by on-line solid-phase extraction-liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

An automatic method for determining diuron, irgarol 1051, folpet and dichlofluanid in seawater samples have been developed. This method is based on the on-line coupling of solid-phase extraction (SPE) with a highly crosslinked polymeric sorbent, LiChrolut EN, to liquid chromatography followed by atmospheric pressure chemical ionization (APCI) and mass spectrometry. The operational parameters affecting the APCI interface have been studied in both positive and negative ionization modes. The use of LiChrolut EN in the SPE produced recoveries of over 85% for all the compounds when 100 ml of seawater sample was preconcentrated. Calibration was carried out in both ionization modes and in full-scan and selected-ion monitoring (SIM). The method allowed all the analytes to be detected at 5 ng l(-1) in SIM acquisition mode except folpet, which, because of its low response, could only be detected at 250 ng l(-1). The method was used to analyse water samples taken from five different marina and fishing ports along the coast of Tarragona, Catalonia (Spain), over a 5-month period. Diuron and irgarol 1051 were detected and quantified in most samples at concentration levels ranging from 27 to 420 ng l(-1) for diuron and from 15 to 511 ng l(-1) for irgarol 1051.

Atmospheric Pressure↗

Occurrence of antifouling biocides in the Spanish Mediterranean marine environment.

A compilation of the results of a monitoring program of the recently used antifouling pesticides diuron (3-(3,4-dichlorophenyl)-1,1-dimethylurea), Irgarol 1051 (2-methylthio-4-tertiary-butylamino-6-cyclopropylamino-s-teiazine), seanine 211 (4,5-dichloro-2-n-octyl-4-isothazolin-3-one), chlorothalonil (2,4,5,6-tetrachloro-isophthalonitrile), dichlofluanid (N'-dimethyl-N-phenylsulphanamide), TCMTB ((2-thiocyanomethylthio) benzothiazole), and three degradation products demethyldiuron (3-(3,4-dichlorophenyl)-1-methylurea),3,4-dichlorophenylurea and 2-methylthio-4-tert-butylamino-s-triazine (Irgarol degradation product) that was carried out between April 1996 and February 2000 in enclosed seawaters from Catalonia and Almería (Spanish Mediterranean coast) is reported. Nine points were sampled along the Catalan coast: Barcelona Olympic port, Masnou, Blanes, Sant Carles de la Ràpita, Tarragona, Cambrils and Salou marinas as well as the Cambrils and Tarragona fishing harbors and in marinas and ports from Almeria: Aguadulce port, Almería port, Almerimar fishing harbour and Almerimar marina. The analytical methodologies were based on Solid Phase Extraction followed by liquid chromatography (LC) or gas chromatography (GC) coupled to a mass spectrometry (MS) or -Diode Array Detector. The main pollutants found in the sampled points were diuron and Irgarol 1051 that were detected at concentrations up to 2.19 micrograms l-1 and 0.33 microgram l-1, respectively. On the other hand, seanine 211 was found at the highest concentration (up to 3.7 micrograms l-1) during the summer of 1999. Low concentrations of dichlofluanid and the above mentioned degradation products were detected for the first time in the Spanish coasts. Chlorothalonil, TCMTB were not found at concentrations higher than 1 and 20 ng l-1 respectively which were the limit of determination (LOD) of the method for these compounds. In general the contamination at the different marinas is higher at the end of spring and in summer where the boating activity is also higher. This paper shows for the first time that the contamination by the new antifouling pesticides in Spanish coastline, basically marinas and fishing harbours, is permanent along the whole calendar year. So, preventive actions by the harbour authorities will be needed in the near future in order to monitor and control the levels and effects of the new antifouling biocides in the marine environment.

Chromatography, High Pressure Liquid↗

Synthesis and evaluation of a molecularly imprinted polymer for selective on-line solid-phase extraction of 4-nitrophenol from environmental water.

A molecularly imprinted polymer (MIP) able to bind 4-nitrophenol (4-NP) was prepared using noncovalent molecular imprinting methods and evaluated as a selective sorbent in molecularly imprinted solid-phase extraction (MISPE) on-line coupled to a reversed-phase HPLC. It has been shown that the conditions chosen for washing the MIP and for eluting the analyte in the MISPE process are extremely important for ensuring good selectivity and recovery. River water samples, spiked with the 11 Environmental Protection Agency phenolic compounds at microgram per liter levels, were preconcentrated on-line using this MIP, and 4-NP was selectively extracted. The humic acid interference was simultaneously reduced considerably. The MIP was also compared with a commercially available highly cross-linked polymer (LiChrolut EN) and the former yielded cleaner extracts.

Chromatography, High Pressure Liquid↗

Determination of naphthalenesulfonates in water by on-line ion-pair solid-phase extraction and ion-pair liquid chromatography with fast-scanning fluorescence detection.

A fast analytical method for quantifying a mixture of 12 naphthalenesulfonates and naphthalenedisulfonates has been developed. This method consists of on-line ion-pair solid-phase extraction with PLRP-s sorbent and ion-pair liquid-chromatography using fast-scanning fluorescence spectrometer as a detection system and multivariate calibration. As complete separation is unnecessary, the compounds were analysed in isocratic conditions and the chromatographic analysis took only 25 min. Three-way partial least-squares (PLS) was used to carry out multivariate calibration for spiked tap water. In these conditions, quantification limits were between 0.01 and 3 microg x l(-1). Repeatability was also evaluated and relative standard deviations (n=3) were between 0.5 and 4, depending on the compound. Finally, spiked tap and Ebro river waters were analysed to evaluate prediction capability of the method.

Calibration↗

Trace determination of antifouling compounds by on-line solid-phase extraction-gas chromatography-mass spectrometry.

A new method based on solid-phase extraction (SPE) on-line coupled to gas chromatography-mass spectrometry through an on-column interface has been applied to determine three antifouling compounds in water samples. Parameters affecting the SPE process and transfer step have been optimised and the method developed has been applied to the analysis of marinas, fishing ports and Ebro river water. The method allows the analytes to be detected at 0.01 microgram l-1 in SIM acquisition mode by preconcentrating only 10 ml of water sample. Different marina and fishing port water samples have been analysed and Irgarol 1051 has been found in some of them at a concentration level equal or lower than 0.05 microgram l-1.

Gas Chromatography-Mass Spectrometry↗

Solid-phase extraction of polycyclic aromatic compounds.

Solid-phase extraction (SPE) for two groups of polyaromatic compounds--polycyclic aromatic hydrocarbons and naphthalenesulfonates--with completely different problems in the extraction process are reviewed. The sorbents used in each case and the different steps of SPE are studied. Particular problems encountered in the SPE of each group are described. Adsorption problems of PAHs which require an organic solvent or a surfactant to be added to the sample are explained. The need of ion-pair solid-phase extraction for extracting naphthalenesulfonates and the influence of the inorganic species in the extraction are discussed. The on-line systems are described for both group of compounds.

Chromatography, Gas↗

Determination of phthalate esters in water samples by solid-phase microextraction and gas chromatography with mass spectrometric detection.

Solid-phase microextraction (SPME) with an 85 microm polyacrylate fiber, coupled to gas chromatography-mass spectrometry was used to determine six phthalate esters and bis(2-ethylhexyl) adipate in water samples. The variables affecting the SPME absorption process were optimized and the method developed was applied to analyze both tap and commercial mineral water samples as well as water from the Ebro river and fishing and industrial ports. For real samples, the linear range in full scan acquisition mode was between 0.02 and 10 microg l(-1) for most compounds, and the limits of detection of the method were between 0.006 and 0.17 microg l(-1). Commercial water samples contained in recipients which were made from different materials were analyzed, and the influence of the material of the recipients on the concentration of phthalates was evaluated.

Esters↗

On-line solid-phase extraction-ion-pair liquid chromatography-electrospray mass spectrometry for the trace determination of naphthalene monosulphonates in water.

This paper presents an HPLC-MS method for the fully automated determination of a group of naphthalene monosulphonates in environmental water samples. The analytical procedure consisted of on-line ion-pair solid-phase extraction using a PLRP-S precolumn and ion-pair LC separation with triethylamine as ion-pair reagent in both cases. A mass spectrometric detector, coupled to LC through an electrospray interface and operated in negative ion mode, was used. Diagnostic ions usually corresponded to [SO3]- and/or [M-SO2H]- together with [M-H] and/or [M-2H+Na]-. The method was applied to the trace determination of several sulphonates present in tap water, seawater and water from the Ebro river. The analytes were determined at a concentration level between 0.05 and 1 microg l(-1) under selected ion monitoring acquisition by preconcentrating just 15 ml of sample. Naphthalene-1-sulphonate and naphthalene-2-sulphonate were identified and quantified in one of the samples of seawater.

Chromatography, High Pressure Liquid↗

Optimization of solid-phase microextraction conditions using a response surface methodology to determine organochlorine pesticides in water by gas chromatography and electron-capture detection.

A response surface methodology was applied to optimise the solid-phase microextraction (SPME) conditions using a polyacrylate-coated fiber to determine thirteen organochlorine pesticides from water. Analyses were performed using gas chromatography-electron-capture detection. Variables affecting absorption in both the headspace and immersion extraction were optimised by using a response surface generated with a Doehlert design, and the results were compared. The immersion SPME method was selected since higher recoveries were obtained for most of the compounds studied. The method developed was applied to the analysis of tap and Ebro river water samples. The linear range of most pesticides for real samples was found to be between 0.001 and 2.5 micrograms l-1 and the limits of detection were between 0.15 and 0.35 ng l-1. The repeatability and the reproducibility between days of the method (n = 6), expressed as relative standard deviation, for tap water spiked at a level of 1 ng l-1 were between 5.7 and 25.6% and between 7.6 and 26.5%, respectively.

Chromatography, Gas↗

Solid-phase microextraction of the antifouling Irgarol 1051 and the fungicides dichlofluanid and 4-chloro-3-methylphenol in water samples.

Three pesticides usually added to paint formulations, Irgarol 1051, dichlofluanid and 4-chloro-3-methylphenol, were determined by solid-phase microextraction (SPME) with 85-micron polyacrylate fibers and gas chromatography-mass spectrometry. The parameters affecting the SPME process (the pH, the addition of salt to the sample, and the time and temperature of the absorption step) were optimized. The method developed was applied to the analysis of water samples from Ebro river, marinas and fishing ports. The method enables these compounds to be detected at concentrations between 0.2 and 3.0 micrograms l-1 under full scan conditions and between 0.05 and 0.08 microgram l-1 under SIM mode.

Absorption↗

On-line coupling of solid-phase extraction to gas chromatography with mass spectrometric detection to determine pesticides in water.

A group of pesticides with different chemical structures was determined in water by on-line coupling of solid-phase extraction to gas chromatography with mass spectrometric detection through an on-column interface. A 10 mm x 2 mm I.D. precolumn packed with PLRP-S was selected for the solid-phase extraction process. The parameters affecting the transfer of the analytes from the precolumn to the GC system (e.g. flow-rate, temperature and solvent vapor exit time) were optimized. An organic modifier was added to the sample before the extraction process to avoid adsorption problems. The use of the MS detector under selected ion monitoring acquisition enabled the analytes to be quantified at sub microgram-per-litre levels preconcentrating only 10 ml of sample, and the limits of detection (S/N = 3) were between 2 and 20 ng l-1. The method was applied to the determination of the pesticides in tap and river water, and molinate was determined in Ebro river water.

Gas Chromatography-Mass Spectrometry↗