PubMed Health⌕ Search

Biomedical subjects

R M Rangayyan

Publications and source records attributed to R M Rangayyan.

34 records · Page 2Linked to original sources

Normal and healing ligament vascularity: a quantitative histological assessment in the adult rabbit medial collateral ligament.

Normal and healing adult rabbit medial collateral ligaments (MCL) have been assessed for microvascular anatomy using a quantitative image analysis methodology. MCL preparation by ink-gelatin perfusion enabled acceptable visualisation of microvascular channels within the tissue. Fifteen adult rabbits were studied; 3 normal rabbits formed an external time-zero control group; 12 animals received a standardised gap injury to the right MCL. The ligament injury was permitted to heal for 3, 6, 17 or 40 wk (3 animals in each healing group). Results confirmed that the normal MCL is hypovascular (about 1.46% vascularity by area) and that microvascular channels are highly organised and oriented longitudinally deep within the tissue. Healing MCL scar becomes twice as vascular as normal ligament early on, but returns to near normal values by 40 wk. Microvascular channels appear less organised in scar than in contralateral controls, but remodel with time. The directional scatter and spatial extent of ligament microvascular channels is quantifiable in normal and healing tissues.

Animals↗

Relationships of the vibromyogram to the surface electromyogram of the human rectus femoris muscle during voluntary isometric contraction.

The relationship between vibromyographic (VMG) and electromyographic (EMG) signals during isometric contraction of the human rectus femoris muscles was studied. The method of least squares was used to obtain the best-fitting linear regression model to the root mean squared (RMS) values of the VMG and the EMG. It is shown that for the rectus femoris of four subjects, a linear VMG versus EMG relationship exists during 20-80% of the maximum voluntary contraction (MVC) at 30 degrees, 60 degrees, and 90 degrees of knee joint flexion angles. The relation between the VMG and the EMG may be explained by the order recruitment of motor units and by the "onion-skin" phenomenon of the firing rates of recruited motor units in the regulation of muscle force production as reported in electro-neurophysiologic studies.

Adult↗

Localization of knee joint cartilage pathology by multichannel vibroarthrography.

This paper proposes non-invasive techniques to localize sound or vibroarthrographic (VAG) signal sources in human knee joints. VAG signals from normal subjects, patients who subsequently underwent arthroscopy, and cadavers with arthroscopically-created lesions, obtained by stimulation with a finger tap over the mid-patella and swinging movement of the leg, were analyzed for time delays using cross-correlation functions for source localization. Correct results were obtained for 13 of the 14 subjects tested by finger stimulation, and for 11 of the 12 subjects whose VAG signals during swinging movement were analyzed. The techniques could be valuable in the diagnosis and treatment of knee pathology before and after joint surgery or drug therapy.

Arthroscopy↗

Adaptive cancellation of muscle contraction interference in vibroarthrographic signals.

Vibroarthrography (VAG) is an innovative, objective, non-invasive technique for obtaining diagnostic information concerning the articular cartilage of a joint. Knee VAG signals can be detected using a contact sensor over the skin surface of the knee joint during knee movement such as flexion and/or extension. These measured signals, however, contain significant interference caused by muscle contraction that is required for knee movement. Quality improvement of VAG signals is an important subject, and crucial in computer-aided diagnosis of cartilage pathology. While simple frequency domain high-pass (or band-pass) filtering could be used for minimizing muscle contraction interference (MCI), it could eliminate possible overlapping spectral components of the VAG signals. In this work, an adaptive MCI cancellation technique is presented as an alternative technique for filtering VAG signals. Methods of measuring the VAG and reference signals (MCI) are described, with details on MCI identification, characterization, and step size optimization for the adaptive filter. The performance of the method is evaluated by simulated signals as well as signals obtained from human subjects under isotonic contraction.

Adult↗

Quantitative analysis of the fine vascular anatomy of articular ligaments.

An image analysis technique has been developed to quantitatively describe the fine vascular patterns observed in ligament tissue. The longitudinal orientational distribution and total vessel volume of India-ink-perfused blood vessel segments in normal and healing ligaments were determined. The methods involved special vascular preparation of adult rabbit knee medial collateral ligaments (MCL) by India-ink perfusion. Black and white microscope images of ink-perfused tissue sections were subjected to a thresholding procedure to binarize digitized ligament images, which were then skeletonized and analyzed for directional distribution based on the least-squares technique. Analysis of medial collateral ligaments in New Zealand White rabbits using this method has shown that scarred tissue is more vascular and has a more chaotic angular distribution of blood-vessel segments than normal ligament tissue.

Algorithms↗

A comparative study of simultaneous vibromyography and electromyography with active human quadriceps.

Vibromyographic (VMG) signals, which are low-frequency vibration signals generated during muscle contraction, were studied in comparison with electromyographic (EMG) signals recorded simultaneously during isometric contraction of the human quadriceps muscles. The comparison was accomplished by evaluating the averaged root mean squared (rms) value, mean frequency (MF), and peak frequency (PF) of the VMG and EMG signals for four muscle contraction levels at joint angles of 30 degrees, 60 degrees, and 90 degrees. The four contraction levels, namely 20, 40, 60, and 80% of maximum voluntary contraction (MVC), were estimated and controlled by the torque readings of a Cybex II dynamometer. It was found that the VMG and EMG under the same conditions on the same muscle group are in general equally sensitive to the levels of muscle contraction. Results show that the rms value of the VMG signal increases linearly, in a manner similar to the EMG rms/%MVC relationship, with increasing muscle contraction levels. Furthermore, the study indicates that the averaged MF (6-24 Hz) and PF (9-19 Hz) of the VMG signals are much lower than the MF (75-109 Hz) and PF (40-80 Hz) of the EMG signals. The slopes of MF/%MVC curves for the VMG and EMG are approximately the same for 60 degrees and 90 degrees joint angles (approximately 3.1 Hz per 20% MVC for VMG and approximately 2.6 Hz per 20% MVC for EMG).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Analysis of knee vibration signals using linear prediction.

Clinical methods used at present for the diagnosis of cartilage pathology in the knee are invasive in nature, and carry some risks. There exists a need for the development of a safe, objective, noninvasive method for early detection, localization, and quantification of cartilage pathology in the knee. This paper investigates the possibility of developing such a method based on an analysis of vibrations produced by joint surfaces rubbing against one another during normal movement. In particular, the method of modeling by linear prediction is used for adaptive segmentation and parameterization of knee vibration signals. Dominant poles are extracted from the model system function for each segment based on their energy contributions and bandwidths. These dominant poles represent the dominant features of the signal segments in the spectral domain. Two-dimensional feature vectors are then constructed using the first dominant pole and the ratio of power in the 40-120 Hz band to the total power of the segment. The potential use of this method to distinguish between vibrations produced by normal volunteers and patients known to have cartilage pathology (chondromalacia) is discussed.

Auscultation↗

Mathematical modeling and spectrum analysis of the physiological patello-femoral pulse train produced by slow knee movement.

Analysis of vibration signals emitted by the knee joint has the potential for the development of a noninvasive procedure for the diagnosis and monitoring of knee pathology. In order to obtain as much information as possible from the power density spectrum of the knee vibration signal, it is necessary to identify the physiological factors (or physiologically relevant parameters) that shape the spectrum. This paper presents a mathematical model for knee vibration signals, in particular the physiological patello-femoral pulse (PFP) train produced by slow knee movement. It demonstrates through the mathematical model that the repetition rate of the physiological PFP train introduces repeated peaks in the power spectrum, and that it affects the spectrum mainly at low frequencies. The theoretical results also show that the spectral peaks at multiples of the PFP repetition rate become more evident when the variance of the interpulse interval (IPI) is small, and that these spectral peaks shift toward higher frequencies with increasing PFP repetition rates. To evaluate the mathematical model, a simulation algorithm was developed, which generates PFP signals with adjustable repetition rate and IPI variance. Signals generated by simulation were seen to possess representative spectral characteristics typically observed in physiological PFP signals. This simulation procedure allows an interactive examination of several factors which affect the PFP train spectrum. Finally, in vivo measurements of physiological PFP signals of normal volunteers are presented. Results of simulations and analysis of signals recorded from human subjects support the mathematical model's prediction that the IPI statistics play a very significant role in determining the low-end power spectrum of the physiological PFP signal.(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

High-resolution digital teleradiology: a perspective.

Teleradiology has come a long way, from analog transmission systems using slow-scan television over standard telephone lines, to present-day, commercially available, microcomputer-based, low-resolution teleradiology systems. However, there exists a need to address the high-resolution end of the medical imaging categories, namely chest radiographs and mammograms, to firmly establish teleradiology. The availability of high-resolution image digitizers, display units, and digital hard copiers has made high-resolution digital teleradiology a feasible concept. Although the use of satellite channels can speed up the transmission of radiographic image data, with widespread acceptance of high-resolution teleradiology systems in the foreseeable future, the sheer amount of data involved in this field will give rise to problems of data transmission and storage. Data compression schemes can bring down the amount of data handled and can have a great economic impact on future teleradiology systems. We have developed a number of compression techniques for reversible compression of medical images. Our experiments have shown that lossless compression of the order of 4:1 is possible for a class of high-resolution medical images. Use of pattern recognition techniques offers the potential to bring down these data rates even further. We plan to use these techniques in a prototype high-resolution teleradiology system being developed. In this paper, we trace some of the developments in teleradiology and image data compression, and present a perspective for teleradiology in the 1990s.

Radiographic Image Enhancement↗

Statistical analysis of collagen alignment in ligaments by scale-space analysis.

Injuries to ligaments in the knee are common in sports and other physical activities. Some clinical methods are available for qualitatively evaluating the degree of ligament injury and healing. It is, however, desirable to objectively assess the healing of ligaments and to predicate optimal treatment on quantitative measurements of their structure. Information such as areas of coverage and spatial orientations of collagen fibrils, for example, may provide important information about the internal structure of ligament tissues. Since normal ligament tissues are made up of collagen fibrils which are highly organized, they can be considered as oriented piecewise linear patterns. In this paper, we propose a computational technique for statistical analysis of collagen alignment in ligament images using the scale-space approach. In this method, a ligament image is preprocessed by a sequence of filters which are second derivatives of two-dimensional Gaussian functions with different scales. This gives a set of zero-crossing maps (the scale space) from which a stability map is generated. Significant linear patterns are captured by analyzing the stability map. The directional information in terms of orientation distributions of the collagen fibrils in the image and the area covered by the fibrils in specific directions are extracted for statistical analysis. Examples illustrating the performance of this method with scanning electron microscope images of the collagen fibrils in healing rabbit medial collateral ligaments are presented in this paper.

Animals↗

Phonocardiogram signal analysis: a review.

Many disease of the heart cause changes in heart sounds and additional murmurs before other signs and symptoms appear. Hence, heart sound analysis by auscultation is the primary test conducted by physicians to assess the condition of the heart. Yet, heart sound analysis by auscultation as well as analysis of the phonocardiogram (PCG) signal have not gained widespread acceptance. This is due mainly to many controversies regarding the genesis of the sounds and the lack of quantitative techniques for reliable analysis of the signal features. The heart sound signal has much more information than can be assessed by the human ear or by visual inspection of the signal tracings on paper as currently practiced. Here, we review the nature of the heart sound signal and the various signal-processing techniques that have been applied to PCG analysis. Some new research directions are also outlined.

Cardiovascular Physiological Phenomena↗

Computed tomography from ordinary radiographs for teleradiology.

Computed tomography (CT) can be achieved inexpensively using ordinary x-ray equipment available at most primary health care centers. We present here the techniques and initial results of experiments with an overhead x-ray unit and film as means for collecting projection data for CT. Our algorithms include standard ART (algebraic reconstruction technique) and modifications we have derived to prevent streaking artifacts due to the use of a small number of views, and to correct geometric distortion due to limited angular coverage. Our methods enable remote computed tomography via teleradiology.

Technology, Radiologic↗