PubMed Health⌕ Search

Biomedical subjects

R M Warner

Publications and source records attributed to R M Warner.

27 records · Page 2Linked to original sources

Assessment of extraction procedures in the analysis of naturally contaminated grain products for deoxynivalenol (vomitoxin).

A comparison of 2 extraction solvent systems (acetonitrile-water, 21 + 4 and methanol-water, 1 + 1) and 3 mixing apparatus (high-speed blender, wrist-action shaker, and mechanical stirrer) was carried out for different extraction time periods. Methods were evaluated using uncontaminated corn spiked with pure deoxynivalenol (DON), field-inoculated (Fusarium graminearum) corn, and uncontaminated and naturally infected wheat in swine diets. After sample extraction, aliquots were passed through alumina-charcoal cleanup columns, evaporated to dryness, dissolved in 8% aqueous methanol, and injected onto the liquid chromatograph. Results confirm published reports of recoveries from DON-spiked samples; however, longer extraction times (less than or equal to 120 min) were required for naturally contaminated samples. Use of the high-speed blender resulted in faster extractions, but in our laboratory more samples could be more conveniently extracted simultaneously with the wrist-action shaker or mechanical stirrer. Less carryover (co-extraction) of interfering contaminants was observed when acetonitrile-water was used vs methanol-water. Results emphasize the importance of careful evaluation of extraction procedures with not only spiked samples but also naturally contaminated samples to establish extraction times required for maximum deoxynivalenol recoveries.

Animal Feed↗

Rapid, sensitive liquid chromatographic method for determination of zearalenone and alpha- and beta-zearalenol in wheat.

A rapid, sensitive liquid chromatographic (LC) method is described for quantitative determination of zearalenone and alpha- and beta-zearalenol in wheat. The procedure incorporates an internal standard, zearalenone oxime, to facilitate quantitation and automated analysis. A sample, buffered with pH 7.8 phosphate, is extracted with water-ethanol-chloroform (2 + 50 + 75) and cleaned up. The final residue is dissolved in LC mobile phase and injected onto a reverse phase RP-18 column under the following conditions: water-methanol-acetonitrile (5 + 3 + 2) mobile phase; fluorescence (excitation wavelength 236 nm, 418 nm cut-off emission filter) and UV (254 nm, range 0.0025 AU) detectors. The limit of detectability (twice background) is 0.5 ng for zearalenone and alpha-zearalenol standards on the fluorescence detector and 4 ng for beta-zearalenol on the UV detector, which is equivalent to 20 micrograms zearalenone and 20 micrograms alpha-zearalenol/kg, and 160 micrograms beta-zearalenol/kg feed. Standard curves are linear over the range 0-35 ng zearalenone and alpha-zearalenol on the fluorescence detector and 0-50 ng beta-zearalenol on the UV detector. Recoveries of all compounds are 87.5-101% in the range 0.1-3.0 mg/kg (ppm).

Chromatography, Liquid↗