PubMed Health⌕ Search

Biomedical subjects

R Mahraj

Publications and source records attributed to R Mahraj.

7 recordsLinked to original sources

Transbronchial biopsy with virtual CT bronchoscopy and nodal highlighting.

Transbronchial biopsy to sample lymph nodes and tumors that are not visible at endoscopy has a poor (<50%) success rate. These nodes can be highlighted easily at virtual computed tomographic (CT) bronchoscopy to provide a guide. This study was performed to evaluate if the addition of this information to the bronchoscopist improved the success rate of transbronchial biopsy of subcarinal and aortopulmonary lymph nodes. The addition of virtual CT bronchoscopy with lymph node highlighting significantly (P < .5) increased biopsy success rates for pretracheal, hilar, and high pretracheal adenopathy.

Adult↗

Routine use of a higher order interpolator and bone algorithm in thoracic CT.

OBJECTIVE: This study was designed to evaluate the utility of the routine use of high spatial frequency algorithms and higher order helical interpolators for imaging lung parenchyma during routine thoracic CT. SUBJECTS AND METHODS: We evaluated 50 consecutive patients undergoing clinically indicated thoracic CT using the same imaging parameters and scanner. The helical volume was reconstructed three separate times using standard and higher order (180 degrees linear with double-sided lobes) interpolators and standard and high spatial frequency (bone) algorithms. The images were photographed and given to five separate readers who were kept unaware of the interpolator and algorithm and who were asked to evaluate simultaneously each patient's three sets of images for best, in-between, and worst images of the lung interstitium, pathology, and normal anatomy. RESULTS: All five readers rated the standard interpolator and algorithm images as the worst (p < .01). All five readers consistently rated the double-sided lobe interpolator and bone algorithm images as the best (p < .01). CONCLUSION: A second reconstruction of routine thoracic helical CT data using higher order helical interpolators and a bone algorithm significantly improves interstitial detail of lung parenchyma and overall visualization of normal anatomy and pathologic processes.

Aged↗

The papillary process: a pseudotumor on coronal and sagittal MRI.

The papillary process of the caudate lobe can extend posteriorly to lie between the inferior vena cava (IVC) and aorta. Occasionally, the papillary process can wrap around the IVC such that its tip lies posterior to the inferior vena cava. These positions of the papillary process create the potential for its misdiagnosis as a lymph node or mass on coronal and sagittal MRI. To evaluate the frequency that this variant occurs, we retrospectively evaluated contrast axial CT scans in 113 adult patients. Ninety-seven percent had a portion of their papillary process extending posterior to the anterior margin of the IVC. In 66% of the patients, the papillary process overlapped more than 50% of the IVC. In these patients, the papillary process would likely appear as a separate soft tissue structure between the IVC and aorta on coronal MRI. In 12 patients, the papillary process not only extended posterior to lie between the IVC and aorta, but actually extended behind a portion of the inferior vena cava as well. This position of the papillary process could appear as a separate soft tissue structure between the IVC and the diaphragmatic crus on sagittal MRI. The posterior extent of the papillary process between the inferior vena cava and aorta, and occasionally, behind the inferior vena cava, are common anatomical variants, knowledge of which may prevent misdiagnosis on coronal and sagittal MRI.

Abdomen↗

Magnetic resonance imaging demonstration of "remodeling" of the aorta following balloon angioplasty of discrete native coarctation.

Assessment of the hemodynamic and anatomic results following balloon angioplasty of discrete native coarctation of the aorta, with particular attention to "remodeling," has required repeat cardiac catheterization and angiography, which is invasive and has limited resolution. Eight patients with hypertension and discrete native coarctation with an otherwise normally developed aortic arch underwent angioplasty at 5.0 +/- 6.8 years of age. Angiographic cross-sectional areas of the aorta indexed to body surface area at the isthmus (I), coarctation site (C), and 1 cm distal to the coarctation site (Cd) pre- and postangioplasty were compared with MRI-indexed cross-sectional areas 18 +/- 10 months (MRI-1) and 35 +/- 11 months (MRI-2) postangioplasty. From preangioplasty to MRI-2, the isthmus was smaller (149 +/- 22 versus 127 +/- 27 mm2/m2; p < 0. 05). The coarctation site was larger postangioplasty (25 +/- 9 versus 116 +/- 40 mm2/m2; p < 0.001) with continued growth at latest follow-up (116 +/- 40 versus 164 +/- 36 mm2/m2; p < 0.01). The segment 1 cm distal to the coarctation site continued to decrease in area at latest follow-up (267 +/- 78 versus 163 +/- 38 mm2/m2; p < 0. 001). I versus C versus Cd at MRI-2 were similar, whereas postangioplasty and MRI-1 cross-sectional area measurements were significantly different. Following angioplasty of discrete native coarctation, the aorta becomes more uniform or undergoes "remodeling." Noninvasive MRI is an effective means of evaluating the anatomic result following balloon angioplasty, obviating the need for repeated invasive cardiac catheterizations.

Adolescent↗

Utility of low mA 1.5 pitch helical versus conventional high mA abdominal CT.

The objective of this study was to evaluate the utility of a low mA 1.5 pitch helical versus conventional high mA conventional technique in abdominal computed tomography (CT). Twenty-five patients who had both a conventional high mA (> 300) and a 1.5 pitch low mA (80-125) helical CT within 3 months were selected for inclusion in the study. Patients were excluded who had a significant change in pathology between the two studies. The other parameters (injection rate, contrast type and volume, and filming window/level) were constant. The studies were randomized and blinded to five separate experienced readers who graded the studies by a variety of normal anatomical structures and pathological criteria. Overview questions also assessed noise, resolution, contrast, and overall quality. The abdominal wall/retroperitoneum and hiatal hernias were statistically better visualized on the conventional high mA studies. However, for all other normal anatomical and pathological sites, there was equivalent or better visualization on the helical versus the conventional CT examinations. The resolution of the helical studies was graded statistically better than the high mA conventional CT scans as was the amount of noise present on the images. While there was some advantage for conventional high mA CT with respect to contrast enhancement and low contrast sensitivity, these differences were not statistically significant. It appears from the data of this study that a low mA technique in evaluating the abdomen may be a useful option in performing routine abdominal CT. The radiation dose savings to the patient is significant and there appears to be little degradation of image quality using a low mA 1.5 helical versus mA conventional CT technique.

Abdominal Muscles↗

The quality of 3D reconstructions from 1.0 and 1.5 pitch helical and conventional CT.

PURPOSE: CT data are commonly used to create 3D images. For this purpose, thin and overlapped slices are desirable. Helical (spiral) CT offers the ability to adjust the slice reconstruction interval from 0 to 100%. However, its use in 1.0 and 1.5 pitch helical CT and 3D imaging, especially with respect to surface detail, is relatively untested. METHODS: Ten objects selected for their varying size, shape, and density were scanned (fourth generation Picker PQ2000) by contiguous 2,4 and 8 mm conventional and helical sequences. The latter were obtained with a pitch of both 1.0 and 1.5 and were reconstructed into a 3D image with 0-75% overlapping of the reconstructed slices. Each of the 24 different sequences per scanned object was reconstructed into identical sets (projections) of 3D images displayed on color film. The 24 3D image sets for each object were submitted to six blinded radiologists who separately ranked them from best to worst. RESULTS: 3D reconstructions obtained from CT scans with a thinner slice thickness, half-field (15 cm FOV), and helical technique were rated as statistically superior. The 1.0 and 1.5 helical sequences obtained with a 4 or 8 mm slice thickness scored statistically better than 3D reconstructions from equivalent conventional scans. Overlapping of the reconstructed helical slices by 25-75% generally improved the quality of the 3D reconstruction. CONCLUSION: Helical CT with either a 1.0 or a 1.5 pitch offers the ability to obtain higher quality 3D reconstructions than from comparable conventional CT scans.

Humans↗

Multiplanar image reconstruction and 3D imaging using a musculoskeletal phantom: conventional versus helical CT.

PURPOSE: Our goal was to perform a detailed comparison of the relative performances of helical CT (pitches 1.0, 1.5, and 2.0) and conventional (overlapped and nonoverlapped) CT in detailed 3D and MPR musculoskeletal imaging. METHOD: A specially designed bone fragment phantom was imaged with multiple slice thicknesses using conventional (overlapped and nonoverlapped) and helical (varying pitch and slice index) CT. Studies were randomized, blinded, and graded using predetermined criteria by 10 radiologists. Statistical analysis included an assessment of raw image scores, a separate testing using duplicate copies of the conventional images as gold standards, and a multivariate model based upon the results of both scoring systems. RESULTS: When assessing raw scores of the images, conventional scans were consistently scored more favorably than helical studies. Decreasing the slice index improved conventional CT studies and helical studies with a pitch of 1.0, but showed no effect on helical studies with a pitch of > 1.0. When using the conventional studies as gold standards, the helical studies were consistently graded as poorer than conventional overlapped and nonoverlapped studies. CONCLUSION: For detailed musculoskeletal 3D and MPR work, helical CT may not adequately compare with conventional CT and offers no discernible advantage, particularly for pitches of > 1.0.

Bone and Bones↗