PubMed Health⌕ Search

Biomedical subjects

R Marcolin

Publications and source records attributed to R Marcolin.

21 records · Page 2Linked to original sources

Extracorporeal circulation in sheep with normal bleeding time using a surface heparinized circuit.

Bleeding due to systemic heparinization represents the major side effect of extracorporeal respiratory support. In the present animal study, a surface heparinized system (Carmeda Biological Active Surface) was applied to assess the feasibility of prolonged perfusion at low circulating heparin levels. Eight sheep divided into two groups: group A (5 animals) and group B (3 animals) underwent venovenous bypass using a heparin coated surface circuit. The following protocol was used: a) 24 hours at high heparin dose (30 to 100 U/kg/hr with an ACT [activated coagulation time] three to four times normal); b) 24 hours at low heparin dose (3 to 8 U/kg/hr with an ACT within the normal range); c) 24 hours at high heparin dose. Group B animals also received fresh frozen sheep plasma (14 ml/kg/day). During Period b, the clotting times were within baseline range. The bleeding time showed a dramatic decrease after change from a to b (27.9 +/- 3 minutes vs. 10.2 +/- 5.6 minutes). There was a negative relationship between antithrombin III (AT III) and thrombin coagulase time (TC); the latter is considered to be an aspecific indicator of circulating fibrin(ogen) degradation products. Maintaining AT III over 70%, TC changes were only minor. The use of the bioactive heparin surface allowed the performance of a 24 hour bypass, with normal coagulation times, at low circulating heparin levels.

Animals↗

Constant mean airway pressure with different patterns of positive pressure breathing during the adult respiratory distress syndrome.

Twenty-one ARDS patients were divided into two groups of severity according to FIO2 and PEEP required to maintain an adequate gas exchange. The 10 most severe patients (group A) underwent continuous positive pressure ventilation (CPPV) (I/E 3:1) with the mean airway pressure maintained at 21 +/- 6.2 cmH2O. The PEEP values were 12.6 +/- 4.3 cmH2O during CPPV and 6.5 +/- 3.7 cmH2O during IRV (p less than 0.01). Eleven less severe ARDS patients (group B) underwent CPPV and positive pressure spontaneous breathing (CPAP) at constant mean airway pressure of 14.3 +/- 3.8 cmH2O. The PEEP was 7 +/- 2.5 cmH2O during CPPV and 14.9 +/- 4.3 cmH2O during CPAP (p less than 0.001). In five patients of each group, the SF6 shunt was measured as representative of true shunt. The results showed that gas exchange, including true shunt, and haemodynamics did not change between CPPV and IRV and between CPPV and CPAP tests. Taken with previous work on mean airway pressure, our results further support the concept that the main determinant of oxygenation and haemodynamics is the mean airway pressure, irrespective of the PEEP level and of the mode of ventilation.

Adolescent↗