PubMed Health⌕ Search

Biomedical subjects

R Meals

Publications and source records attributed to R Meals.

4 recordsLinked to original sources

Radioulnar load-sharing in the forearm. A study in cadavera.

Custom-designed miniature load-cells were inserted into the distal end of the ulna and the proximal end of the radius in ten fresh-frozen forearms from cadavera. The forces transmitted through the bones at these sites were measured under 134 newtons of constant axial load that was applied through the metacarpals as the forearm was rotated from 60 degrees of supination to 60 degrees of pronation. The simultaneous measurements of these forces allowed the calculation of radioulnar load-sharing at the wrist and the elbow as well as the calculation of the amount of force that was transferred from the radius to the ulna through the interosseous membrane. With the elbow in valgus alignment (that is, with contact between the radial head and the capitellum), the main pathway for load transmission through the forearm was direct axial loading of the radius; measurements from both load-cells were unaffected by the angle of elbow flexion. When the forearm was in neutral rotation, the mean force in the distal end of the ulna averaged 2.8 per cent of the load applied to the wrist and the mean force in the proximal end of the ulna averaged 11.8 per cent; this indicated that only a small amount of tension developed in the interosseous membrane. With the elbow in varus alignment (that is, with no contact between the radial head and the capitellum), load was transmitted through the forearm by a transfer of force from the radius to the ulna through the interosseous membrane. When the forearm was in neutral rotation, the force in the distal end of the ulna averaged 7.0 per cent of the load applied to the wrist and the force in the proximal end of the ulna averaged 93.0 per cent; the force through the interosseous membrane decreased with supination of the forearm. Testing with the elbow in valgus alignment and shortening of the distal end of the radius in two-millimeter increments produced corresponding increases in force in the distal end of the ulna and decreases in force in the radial head. The forces through the interosseous membrane remained low after each amount of radial shortening.

Aged↗

Use of the Taguchi method for biomechanical comparison of flexor-tendon-repair techniques to allow immediate active flexion. A new method of analysis and optimization of technique to improve the quality of the repair.

The current trend toward early active flexion after repair of the flexor tendons necessitates a stronger repair than that provided by a modified Kessler technique with use of 4-0 nylon suture. The purpose of the current study was to determine, with use of the Taguchi method of analysis, the strongest and most consistent repair of the flexor tendons. Flexor tendons were obtained from fresh-frozen hands of human cadavera. Eight flexor tendons initially were repaired with the modified Kessler technique with use of 4-0 nylon core suture and 6-0 nylon epitenon suture. A test matrix was used to analyze a total of twenty variables in sixty-four tests. These variables included eight techniques for core-suture repair, four types of core suture, two sizes of core suture, four techniques for suture of the epitenon, and two distances from the repair site for placement of the core suture. After each repair, the specimens were mounted in a servohydraulic mechanical testing machine for tension-testing to failure. The optimum combination of variables was determined, with the Taguchi method, to be an augmented Becker technique with use of 3-0 Mersilene core suture, placed 0.75 centimeter from the cut edge with volar epitenon suture. The four-strand, double modified Kessler technique provided the second strongest repair. Five tendons that had been repaired with use of the optimum combination then were tested and compared with tendons that had been repaired with the standard modified Kessler technique. With the optimum combination of variables, the strength of the repair improved from a mean (and standard deviation) of 17.2 +/- 2.9 to 128 +/- 5.6 newtons, and the stiffness improved from a mean of 4.6 to 16.2 newtons per millimeter.

Biomechanical Phenomena↗

One hundred years of automobile-induced orthopedic injuries.

As the automobile has evolved over its first 100 years, many changes have improved its safety and have resulted in lower fatality rates. To a great extent, physicians have provided the thrust for these improvements. Now, as more people survive automobile accidents, injuries to the musculoskeletal system take on importance as causes of individual disability and social cost. The patterns of automobile-induced orthopedic injuries continue to change. This article reviews the first 100 years of these injury patterns and relates their occurrence to specific automobile design features and oversights. Because any one automobile accident is likely to injury only a few people at most, trends and patterns are much more difficult to ascertain than for mass transit vehicular accidents. For this reason, physician awareness of contemporary injury patterns is the first step toward safer automobile design.

Accidents, Traffic↗