Strategies for locating disulfide bonds in a monoclonal antibody via mass spectrometry.

The location of the disulfide bonds in a recombinant monoclonal antibody was confirmed by matrix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) and electrospray ionization (ESI) mass spectrometry (MS). A non-reduced Endoproteinase Lys-C (Endo Lys-C) digest of the antibody was analyzed directly by MALDI-TOFMS. The sample was then reduced on-plate by depositing dithiothreitol (DTT) on the sample spot and re-analyzed by MALDI-TOFMS. The disulfide bonds were assigned based on the disappearance of certain mass ions in the non-reduced digest and the appearance of product ions in the reduced digest. A rapid LC/ESI-MS protocol was also developed to determine the location of the disulfide bonds. The peptides generated from the Endo Lys-C digest of the antibody were partially separated on a high performance liquid chromatography (HPLC) column by utilizing a steep gradient and analyzed by ESI-MS. The masses of the partially resolved peptides were determined by deconvoluting the mass spectra.

Antibodies, Monoclonal↗

Characterization of antigen-antibody complexes by size-exclusion chromatography coupled with low-angle light-scattering photometry and viscometry.

In this paper, the molecular masses (M(r)s) of the complexes of monoclonal anti-BSA (antibody to bovine serum albumin) (clone: 33) and monomer BSA were determined on-line by using size-exclusion chromatography (SEC) coupled with a low-angle laser light-scattering (LALLS) detector and two concentration detectors, ultraviolet (UV) and refractive index (RI) (SEC-LALLS/UV/RI system). Also, the size and M(r)s of the complexes were evaluated by the SEC-LALLS/UV/viscometer (VISC) system. This study demonstrated that, for small size macromolecules, the combination of light scattering and viscosity detection was a suitable choice for determining their M(r)s and sizes.

Antibodies, Monoclonal↗

Rapid purification and monitoring of immunoglobulin M from ascites by perfusion ion-exchange chromatography.

A purification and on-line monitoring procedure for IgM was developed. Perfusion ion-exchange chromatography was used for rapid purification of IgM from ascites fluid and hybridoma supernatant. Crude ascites was directly loaded onto an ion exchanger. Due to the complexity of IgM, a two-step ion-exchange procedure had to be developed. This procedure involved a rapid cation-exchange chromatography capture step followed by further purification using anion-exchange chromatography. High linear velocities, in excess of 3500 cm/h, enabled separations to be performed under 5 min. Purity of the final product by SDS-PAGE was shown to be greater than 95%. Furthermore, the antibodies retained biological activity as measured by indirect immunofluorescence (IIF) and ELISA. The IgM peak was also monitored on-line using a novel peak tracking approach. This involved placing an antibody column (specific to the IgM) prior to the ion-exchange column and operating the ion-exchange column with and without the antibody column in-line. The missing peak that is identified by comparing the two chromatograms indicates where the IgM elutes.

Animals↗

Capillary electrophoresis-based immunoassay for cortisol in serum.

A competitive immunoassay for cortisol based on capillary electrophoresis (CE) and laser-induced fluorescence is described. The work involved the production of assay reagents and the development of separation conditions allowing for routine analysis of serum samples. Fluorescein-labeled cortisol was synthesized and purified. Fab fragments were produced from mouse monoclonal anticortisol antibody and purified using a POROS cation exchange chromatography column. After incubation of these reagents with serum, free and bound labeled antigen were separated by CE with high reproducibility. No prior sample cleanup of the serum samples was necessary. Serum calibration curves were established and used for the quantitation of cortisol in serum. The results demonstrate feasibility for a cortisol assay based on CE operating directly on serum samples.

Electrophoresis↗

Determination of on-line differential refractive index and molecular weight via gradient HPLC interfaced with low-angle laser light scattering, ultraviolet, and refractive index detection.

Gradient ion-exchange chromatography (IEC) was interfaced with a low-angle laser light scattering photometer (LALLS) and ultraviolet (UV) and refractive index (RI) detectors connected in series for on-line determination of the differential refractive index (dn/dc) of proteins and eventually their molecular weights (Mw's). Interfacing of gradient HPLC with a RI detector was made possible by using two isorefractive buffers, which helped generate stable baselines for the LALLS and RI detectors. An optically modified, laser based RI detector was used for determination of dn/dc. On-line determinations of dn/dc required smaller amounts of sample compared to off-line determinations (3-4 mg vs 200 mg). Also, dn/dc could be measured by making one repetitive injection of the sample, if the molar absorptivity of the sample was known. dn/dc values determined on-line were in close agreement with those determined off-line. Additionally, percent recovery of the sample was calculated on-line, and this provided true concentration detected at the UV detector, which was then used for determination of Mw.

Chromatography, High Pressure Liquid↗

Determination of biopolymer (protein) molecular weights by gradient elution, reversed-phase high-performance liquid chromatography with low-angle laser light scattering detection.

The determination of molecular weights for certain proteins has been performed. This has involved the on-line coupling of gradient elution, reversed-phase high-performance liquid chromatography (RP-HPLC) with low-angle laser light scattering (LALLS) detection. A new 1.5-micron, non-porous, Monosphere RP-C8 column has been used in order to perform fast and conventional RP-HPLC gradients (5-45 min). Traditional specific refractive index increment (dn/dc) and refractive index (n) measurements have been performed in order to derive absolute weight-average molecular weight (Mw) information for ribonuclease A, lysozyme, and bovine serum albumin. Standard mixtures of known concentrations of each protein have been separated using reversed-phase gradients utilizing acetonitrile with on-line LALLS determination of excess Rayleigh scattering factors. Accurate Mw data have been obtained for all three proteins, but only under certain, conventional reversed-phase gradient elution conditions. Between 5-10 min of fast gradient elution, each protein appears to exhibit unusual Mw values, suggestive of aggregate formations. Methods have been developed to define the nature of such aggregates. The on-line coupling of modern RP-HPLC for biopolymers with LALLS represents a major step forward in the ability of bioanalytical chemists to determine the nature (monomer versus aggregate) of such materials. Other classes of biopolymers should prove suitable for studies with the same RP-HPLC-LALLS-UV approaches.

Acetonitriles↗