PubMed HealthSearch

Biomedical subjects

R Mohan

Publications and source records attributed to R Mohan.

At least 91 records · Page 5Linked to original sources

Validity of the concept of separating primary and scatter dose.

The technique of separating dose into primary and scatter components for calculating photon dose distributions is widely used. The primary and scatter dose models ignore ignore the fact that electrons have a finite range. This may be a good approximation for 60Co photons but not for higher energies. For the latter, the range of electrons may be several centimeters in soft tissue and even longer in lungs and will lead to errors in computed dose in regions where electronic equilibrium does not exist. Ignoring the finite range of electrons will affect dose at points such as those near the beam boundaries, near inhomogeneity boundaries, and at bone-soft-tissue interfaces. Other possible problems associated with the definition and use of "primary" and "scatter" dose in dose distribution calculations result from extrapolation of measured data to obtain data for zero and very large field sizes and from the use of these quantities, which are defined for central axis, for points at large distances from the central axis. This paper examines the limits of the validity of these assumptions.

Cobalt Radioisotopes

Energy and angular distributions of photons from medical linear accelerators.

For accurate three-dimensional treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the photons incident on the surface of the patient. Knowledge of the spectra is also useful in other applications, including the design of filters and beam modifying devices and determination of factors to convert ionization chamber measurements to dose. We have used Monte Carlo code (EGS) to compute photon spectra for a number of different linear accelerators. Both the target and the flattening filter have been accurately modeled. We find the mean photon energy to have a value lower than the generally perceived value of one-third the maximum energy. As expected, the spectra become softer as the distance from the central axis increases. Verification of the spectra is performed by computing dose distributions and half-value layers in water using the calculated spectra and comparing the results with measured data. We also examined the angular distributions of photons incident on the surface of the phantom. In currently used models of dose computations, it is assumed that the angular distribution of photons with respect to fan lines emanating from the source is negligible. Although the angular spread of photons with respect to the incident direction has been found to be small, its contribution to the diffuseness of the beam boundaries is significant.

Energy Transfer

Off-center ratios for three-dimensional dose calculations.

A new method is proposed for computing the off-center ratios (OCR's) in three-dimensional dose calculations. For an open field, the OCR at a point is computed as the product of the primary OCR (POCR) and the boundary factors (BF's). The POCR describes the beam profile for an infinite field, that is, without the effect of the collimators. It is defined as the ratio of the dose at a point off the central ray to the dose at the point on the central ray at the same depth for an infinite field. The POCR is a function of radial distance from the beam central ray and depth. The BF describes the shape of the beam in the neighborhood of the field boundary defined by the collimators. It is defined as the ratio of the OCR at a point for a finite field to the OCR at the same point for an infinite field. The BF is a function of distance from the field boundary, depth, and field size. For a wedged field, we assume that the boundary factors remain the same as for open fields but the POCR's are altered. The changes in beam profiles are described by a factor called the wedge profile factor (WPF), defined as the ratio of the dose at a point for the largest wedged field to the dose at the same point for an open field of the same field size. The WPF is a function of lateral distance from the beam central plane and depth. Calculated OCR's using this new method are in agreement with the measured data along both the transverse and the diagonal directions of the field.

Biometry

Differential pencil beam dose computation model for photons.

Differential pencil beam (DPB) is defined as the dose distribution relative to the position of the first collision, per unit collision density, for a monoenergetic pencil beam of photons in an infinite homogeneous medium of unit density. We have generated DPB dose distribution tables for a number of photon energies in water using the Monte Carlo method. The three-dimensional (3D) nature of the transport of photons and electrons is automatically incorporated in DPB dose distributions. Dose is computed by evaluating 3D integrals of DPB dose. The DPB dose computation model has been applied to calculate dose distributions for 60Co and accelerator beams. Calculations for the latter are performed using energy spectra generated with the Monte Carlo program. To predict dose distributions near the beam boundaries defined by the collimation system as well as blocks, we utilize the angular distribution of incident photons. Inhomogeneities are taken into account by attenuating the primary photon fluence exponentially utilizing the average total linear attenuation coefficient of intervening tissue, by multiplying photon fluence by the linear attenuation coefficient to yield the number of collisions in the scattering volume, and by scaling the path between the scattering volume element and the computation point by an effective density.

Bone and Bones

A technique for computing dose volume histograms for structure combinations.

Graphical displays of three-dimensional dose distribution data are often too complex to be easily assimilated and interpreted for the evaluation of radiation treatment plans. Histograms showing dose versus volume are convenient and useful tools for summarizing dose distribution information throughout the entire volume of a given anatomic structure. They can quickly highlight characteristics such as dose uniformity and hot and cold spots, and can be used to produce statistics including tumor control and normal tissue complication probabilities. To obtain a dose volume histogram for a given structure, it may be necessary to examine its spatial relationships with neighboring structures. They may overlap, be completely disjoint, or one may be contained within another. To resolve potential ambiguities, a procedure has been developed that assigns hierarchies to anatomical structures for the purpose of histogram calculation. The hierarchy assigned to each structure is used to determine the structure within which a given dose matrix point is considered to lie. In this manner, regions of structure intersection are assigned to one object or another, and dose volume histograms can be calculated for each structure separately. From this framework, addition and subtraction of histograms can also be performed. Details of the algorithm are presented along with an example using patient data.

Algorithms

Use of fast Fourier transforms in calculating dose distributions for irregularly shaped fields for three-dimensional treatment planning.

In three-dimensional radiation treatment planning, essentially all fields are irregular and compensated. Consequently, it is important to predict accurately dose for such fields to ensure adequate coverage of the target region and sparing of healthy tissues. Traditional approaches, namely, those involving scatter integration and extended source and those utilizing negatively weighted fields, are inaccurate, especially near the boundaries defined by blocks and collimators. In the method presented in this paper, dose distributions for arbitrarily shaped beams are calculated by two-dimensional convolution of the relative primary photon fluence distributions and kernels representing the cross-sectional profiles of a pencil beam at a series of depths. The pencil beam dose distributions are computed, once and for all, with the Monte Carlo method for photon energy spectrum for each treatment machine. The finite size of the source, which is important for cobalt machines, is also taken into account using convolution of the source with the relative primary fluence distribution. Convolutions are performed using fast Fourier transforms on an array processor. Results of calculations are in excellent agreement with measured data. While no data are presented for fields modified by compensators, the method of calculation should apply at least as well for such fields since the variations in fluence distribution for compensated fields are not as sharp as for points near the block boundaries.

Biophysical Phenomena

Monte Carlo simulation of a cobalt-60 beam.

We have used the Stanford Electron Gamma Shower (EGS) Monte Carlo code to compute photon spectra from an AECL Theratron 780 cobalt-60 unit. Particular attention has been paid to the careful modeling of the geometry and material construction of the cobalt-60 source capsule, source housing, and collimator assembly. From our simulation, we conclude that the observed increase in output of the machine with increasing field size is caused by scattered photons from the primary definer and the adjustable collimator. We have also used the generated photon spectra as input to a pencil beam model to calculate the tissue-air ratios in water and compared it to a model which uses a monochromatic photon energy of 1.25 MeV.

Cobalt Radioisotopes

Dose computations for asymmetric fields defined by independent jaws.

Asymmetric fields defined by independent jaws can be used to split a beam or to match adjacent fields. We have extended a method originally developed for symmetric fields to calculate the dose for asymmetric fields. The dose to a point is computed as the product of the tissue maximum ratio (TMR), the off center ratio (OCR), and the inverse square factor. The TMR is computed from the measured central axis depth doses for symmetric fields. The OCR is obtained by multiplying the primary OCR (POCR) and the boundary factors (BF's) for the four jaws. The POCR's and BF's were derived from measured beam profiles, which include the effect of off-axis beam quality variations. Using this method, the beam profiles and isodose distributions for asymmetric fields of a 6-MV accelerator were calculated and compared with the measured data. The agreement is within experimental errors both in the penumbra region and along the central ray of the asymmetric field.

Humans

The effect of angular spread on the intensity distribution of arbitrarily shaped electron beams.

Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-dimensional step function whose shape corresponds to the applicator aperture. Two different approaches to obtain angular spread or the equivalent spatial spread are investigated. In the first method, the pencil beam angular spread is assumed to be Gaussian in shape. The angular spread constants (sigma theta) are then obtained from the slopes of measured intensity profiles. In the second method, the angular spread, in the form of an array of numerical values, is obtained by the deconvolution of measured intensity profiles. After obtaining the angular spread, the calculation for convolution is done in a number of parallel planes normal to the central axis at various distances from the electron collimator. Intensity at any arbitrary point in space is computed by interpolating between intensity distributions in adjacent planes on either side of the point. The effects of variations in angular spread as a function of field size for two treatment machines, one with a scanned electron beam and the other with a scattering foil, have been studied. The consequences of assuming angular spread to be of Gaussian shape are also examined. The electron intensity calculation techniques described in this paper apply primarily to methods of dose calculations that employ pencil beams generated using Monte Carlo simulations.

Electrons

Extraction of pencil beam kernels by the deconvolution method.

A method has been developed to extract pencil beam kernels from measured broad beam profiles. In theory, the convolution of a symmetric kernel with a step function will yield a function that is symmetric about the inflection point. Conversely, by deconvolution, the kernel may be extracted from a measured distribution. In practice, however, due to the uncertainties and errors associated with the measurements and due to the singularities produced in the fast Fourier transforms employed in the deconvolution process, the kernels thus obtained and the dose distributions calculated therefrom, often exhibit erratic fluctuations. We propose a method that transforms measured profiles to new, modified distributions so that they satisfy the theoretical symmetry condition. The resultant kernel from the deconvolution is then free of fluctuations. We applied this method to compute photon and electron dose distributions at various depths in water and electron fluence distributions in air. The agreement between measured and computed profiles is within 1% in dose or 1 mm in distance in high dose gradient regions.

Fourier Analysis

Compensators for three-dimensional treatment planning.

Presented here is a method of designing compensators for a single beam or one or more pairs of beams, not necessarily parallel opposed. The objective is to produce a flat distribution in a plane that may be perpendicular to the central ray or may be an arbitrarily oriented plane, for example, a plane that bisects the hinge angle between two beams. The method takes into account not only surface irregularities but also tissue inhomogeneities, hinge angles between beams, distance from the source, and even "horns" in the beam. The design process employs convolution of Monte Carlo generated pencil beams with photon fluence distributions, appropriately modified for the presence of beam modifiers (blocks and compensators), to compute dose in a flat homogeneous phantom. Corrections for inhomogeneities and surface curvature are applied by using computerized tomography information to determine the effective path length through tissue. Multiple interactions are used to arrive at a compensator that properly incorporates changes in radiation transport, and therefore dose distribution, resulting from the presence of beam-shaping devices. In each iteration it is assumed that the required reduction in dose at a point can be achieved by reducing the fluence along the ray joining the source to computation point proportionately. The compensator design is represented as a finely spaced matrix of thickness values which is entered into a prorammable milling maching for fabrication. Dose measurements in phantom exposed to 6-MV x rays with and without compensation are presented.

Equipment Design

Clinically relevant optimization of 3-D conformal treatments.

In this paper a method of computer-aided optimization of 3-D conformal treatment plans is presented which incorporates models to predict the clinical consequences of resulting dose distributions. Even though these models are simplistic, it is submitted that their intelligent use leads to treatment plans which indicate lower normal tissue complications and higher tumor control. Dose distribution data, biological models, and observed normal tissue and tumor response data are used to compute tumor control and normal tissue complication probabilities for each of the critical normal structures encountered in a treatment plan. These quantities are combined into a single score using an objective function which incorporates the importance of each end point as assessed by the physician. Using the "simulated annealing" method of optimization, the beam weights are adjusted to maximize the score. Additional constraints are applied to ensure consistency of the results of optimization with the judgment of the physician. These optimization methods have been applied to conformal treatment plans consisting of multiple fixed fields with conformal field shaping. The results indicate that the methods presented have considerable potential.

Aged

A model for computer-controlled delivery of 3-D conformal treatments.

Three-dimensional conformal radiation treatments are highly complex and may comprise a large number of coplanar and noncoplanar beams, virtually all of which are shaped and may also employ arbitrary intensity modulation. The delivery of such treatments with conventional means is highly labor intensive and limited to a relatively small number of fields. A generalized model for a system that can deliver 3-D conformal treatments rapidly and safely using a computer-controlled treatment machine equipped with a multileaf collimator is presented. The model emphasizes the separation of tasks between an external computer programmed by the user institution and a control computer proprietary to the treatment machine manufacturer. The treatment scheme that is employed consists of a sequence of fixed fields, called segments, which are delivered in succession without human intervention. Settings for all segments, derived from a 3-D conformal treatment planning system, are downloaded by the external computer into the control computer of the treatment machine. During patient setup, the control computer enables the operator to step through computer-controlled setup of the segments without radiation to ensure the absence of collisions, and to allow the adjustment of setup parameters if necessary. The external computer verifies the treatment setup and permits the control computer to carry out the treatment segment by segment. Safety aspects of the model and anomalous situations which may arise are discussed.

Computer Simulation

High prevalence of maturity-onset diabetes of the young (MODY) among Indians.

This article describes the high prevalence of maturity-onset diabetes in the young (MODY) in an Indian clinic population of diabetic patients. MODY appears to be more common among Indians than among Caucasians. Only 27% of MODY patients had definite autosomal-dominant inheritance. In 73% the mode of inheritance was not definite. Microvascular complications were common and macrovascular complications rare. The high prevalence of MODY in this diabetes clinic might suggest an ethnic variation in diabetes.

Adult

Acanthamoeba keratitis--a report of two cases.

Two cases of unilateral corneal ulcers caused by Acanthamoeba are reported. Neither of the patients had contact lenses at any time. The diagnosis was confirmed by Giemsa stain and cultures of the corneal scrapings.

Acanthamoeba

Comparative efficacy of atenolol and labetalol in essential hypertension--a double blind cross over trial.

In a double blind cross-over drug trial, antihypertensive effects (resting and after dynamic exercise) of atenolol and of labetalol were studied in 20 patients of mild to moderate essential hypertension. Both drugs exhibited almost equal antihypertensive response, and were well tolerated. Haemodynamic variables (HR, SBP, DBP and RPP), both at rest and after maximal tread mill exercise, were significantly altered (P less than 0.001) by both drugs. Exercise capacity was observed to be marginally improved by atenolol. Although the antihypertensive effect, when compared between the two drugs, was not statistically significant, individual suitability or comparison revealed a preference for atenolol in 17 patients and for labetalol in 3 patients.

Adult

Steroid induced glaucoma and cataract.

Long term use of topical & systemic steroids produce secondary open angle glaucoma similar to chronic simple glaucoma. The increased IOP caused by prolonged steroid therapy is reversible but the damage produced by it is irreversible. In this study, we analysed 25 patients (44 eyes) with steroid induced glaucoma, who reported to us with dimness of vision, haloes and elevated I.O.P. and were using steroids for long duration due to various causes. The behaviour of the I.O.P. due to different steroid preparations, the type of lenticular change, and the management of those cases are discussed in this paper. From our study we conclude that dexamethasone and betamethasone both topical as well as systemic are more potent in producing glaucoma and cataract than medrysone and prednisolone. The condition is reversible without permanent damage when the duration of steroid therapy is short and vice versa.

Adolescent