PubMed Health⌕ Search

Biomedical subjects

R Muchada

Publications and source records attributed to R Muchada.

At least 19 recordsLinked to original sources

[Anaesthesia for a non cardiac surgery in a patient with an Eisenmenger syndrome. Interest of a non invasive haemodynamic monitoring].

Patients with an Eisenmenger syndrome have an instuble hemodynamic status. During a general anaesthesia, the intracardiac shunt has to maintain the correct orientation and volume, adapted to each patient, in such a condition, to avoid the risk of hypoxemia and cardiac failure. The haemodynamic monitoring with a Swan Ganz catheter could be useful. But it is necessary to evaluate the advantage and the risks when the technique is used in these pathological circumstances. Moreover, when the cardiac output is measured with the thermodilution technique, the right-left intra cardiac shunt volume, is not taking into account. The continuous haemodynamic monitoring, with a simplified transoesophageal echo-Doppler system, as it was done in this case, allows appreciate the real quantitative variations of the shunt. In this way the more adequate calculation of some others haemodynamic parameters, over all the total systemic vascular resistances, allows a more precise therapeutic approach.

Anesthesia↗

[Carotid endarterectomy under remifentanil].

OBJECTIVE: Carotid endarterectomy can be performed under general or locoregional anesthesia. If locoregional anesthesia is chosen, the state of awareness of the patient allows for direct viewing of the effect of vascular clamping of the corresponding neurological territory. We present the results of an anesthetic procedure using only an analgesic in patients who were intubated and ventilated but with a level of consciousness that allowed us to view the effect of carotid clamping on motor functions. METHOD: Forty-eight patients, ASA II-III, underwent surgical carotid endarterectomy. The anesthetic protocol began with preoxygenation for 2 min; induction with remifentanil 0.75-1 microgram kg-1 for 2 min., followed by perfusion of 1 microgram/kg-1.min-1 of remifentanil and propofol 1 microgram/kg-1; and orotracheal intubation by local anesthesia of the glottis with 5% lidocaine spray. Ventilation was with FiO2 100%, FR 12 min. and VT 8 ml. kg-1. For maintenance the dose of remifentanil was regulated to obtain a coordinated motor response (maximum 1.5 microgram/kg-1.min-1, minimum 0.35 microgram/kg-1. min-1). For all patients we monitored hemodynamics continuously and non-invasively, including aortic output by the transesophageal Doppler echocardiography. RESULTS: The objective of anesthesia was reached in all the patients. The most common hemodynamic alterations were bradycardia (28), arterial hypotension (25), elevated blood pressure (3) and altered aortic output. All changes were corrected quickly with the treatment used, guided by the evolution of hemodynamic parameters. Postanesthetic recovery came in less than 4 min. The only episodes of hyper -and hypotension consisted of a few episodes of mild hyper- (12) and hypotension (1), which were soon corrected. No alterations attributable to hemodynamic instability occurred. During surgery, an intracarotid shunt was necessary in only one patient. Three suffered surgically-related neurological complications after the operations. No complications could be attributed to anesthesia. DISCUSSION: An advantage of this technique is that the duration of anesthesia is not limited, with adequate ventilation and maintenance of an adequate state of consciousness for clinical evaluation of the repercussions of carotid clamping. Hemodynamic monitoring detected the appearance of imbalances requiring therapeutic intervention. The procedure is interesting provided it is performed according to a strict protocol, with continuous clinical and instrumental monitoring of the patient's status.

Aged↗

Detection of vascular haemodynamics through a high-speed velocity profiler.

OBJECTIVE: This paper aims at demonstrating that ultrasound Doppler multigate spectral analysis performed with advanced equipment may provide detailed and significant haemodynamic information. METHODS: A novel multigate system was recently introduced and shown capable of performing real-time spectral analysis of Doppler data from 64 resolution cells located at different depths from the transducer. The system extends the typical capabilities of conventional Pulsed Wave (PW) equipment by displaying the full spectral content of Doppler signals over an ultrasound scan line rather than in a single resolution cell. In cases where it is appropriate to display the available information in a simpler form, parameters such as the maximum frequency can be extracted from each spectrum, by using conventional or advanced image processing methods. RESULTS: In-vitro experiments show that the multigate system can perform velocity measurements with good accuracy and precision. Examples of in vivo profiles detected from carotid, femoral and radial arteries are presented. In particular, the first results obtained from the aorta are shown. CONCLUSIONS: Blood flow behavior can be accurately investigated using a real-time multigate system which extends Doppler spectral analysis to a whole scan line.

Aorta↗

Measurements of systolic time intervals using a transoesophageal pulsed echo-Doppler.

Measurement of systolic time intervals (STI), an index of left ventricular (LV) systolic function, is usually labour intensive and requires considerable expertise to perform accurately. We have evaluated the accuracy of an automated, continuous and non-invasive STI measurement technique using a descending aortic blood velocity Doppler signal obtained using a transoesophageal echo-Doppler system (TEDS) and an ECG signal. STI were measured in adult pigs using a transoesophageal probe (4 x 4 mm pulsed wave Doppler transducer, 5-MHz frequency and a 3 x 3 mm echo transducer, 10-MHz frequency) associated with an ECG recorder. Measurements were performed at baseline and after injection of esmolol and dobutamine. TEDS data were compared with those obtained by one-line recordings of the electrocardiogram and the central aortic arterial pressure wave. Similar mean values were observed for pre-ejection period (PEPI), LV ejection time (LVET) and PEP/LVET with the two methods. Agreement between the methods (Bland and Altman's test) was excellent with 95% confidence intervals for PEP, LVET and PEP/LVET of -7.17 to +1.37 ms, -12.64 to +0.24 ms and -0.033 to +0.028, respectively. We conclude that the combination of descending aorta blood velocity Doppler and ECG signal is an alternative technique for non-invasive and objective measurement of STI, allowing continuous monitoring of LV systolic function.

Animals↗

Haemodynamic changes during anaesthesia in knee-elbow position.

BACKGROUND: To evaluate hemodynamic alterations during surgical procedures performed in the knee-elbow position. METHODS DESIGN OF THE STUDY: prospective evaluation of the aortic blood flow (ABF) and other cardiovascular variables measured with a transesophageal Doppler (TED) in 2 groups of patients free of previous cardiovascular diseases undergoing lumbar discectomy. ENVIRONMENT: Operating theatre of a neurosurgical department. Beside TED, the standard monitoring included continuous ECG surveillance, capnometry, noninvasive measurement of blood pressure and pulsoxymetry. PATIENTS: Overall, 24 ASA 1 patients have been enrolled. In 12 patients (Group A) the intervention was performed without dobutamine. In the other 12 patients (Group B) dobutamine (2.5-3 micrograms/kg/min) was started from the beginning of the intervention; the two groups did not differ in terms of age, body size, duration of surgery or anesthetic technique used; hemodynamic measurements were obtained at the beginning of the intervention (T1), with the patients still supine, during the intervention in the knee-elbow position (T2) and finally at the end of the procedure (T3) being the patients still anesthetized but lying supine again. RESULTS: In both groups the ABF; the systolic volume and the ETCO2 significantly decreased in the knee-elbow position; concomitantly, peripheral vascular resistances increased. In Group B, the hemodynamic variables were significantly better than in the other group. CONCLUSIONS: In the patients enrolled, the perioperative administration of low-dose dobutamine was associated with better cardiovascular performance.

Adrenergic beta-Agonists↗

Continuous oesophageal aortic blood flow echo-Doppler measurement during general anaesthesia in infants.

PURPOSE: Invasive haemodynamic monitoring during general anaesthesia in infants is usually limited to very high risk operations, such as cardiac surgery. Nevertheless, different surgical procedures and/or anaesthetic techniques justify additional monitoring for children, as for adults. The aim of this preliminary study was to evaluate the feasibility of using a new echo-Doppler device (Dynemo 3000) capable of measuring continuous aortic blood flow during general anaesthesia in infants. METHODS: Aortic blood flow (ABF) was measured with a small oesophageal probe designed for newborns and infants. The aortic flowmeter was connected with satellite devices to visualise the haemodynamic profile which included ABF, pre-ejection period (PEPi), left ventricular ejection time (LVETi), mean arterial pressure, heart rate, stroke volume and systemic vascular resistance. Twelve infants, aged 8-26 mo, undergoing surgery under general anaesthesia were successively included in the evaluation of this device. Isoflurane (1% end-expired concentration) was introduced to maintain anaesthesia after induction with halothane, midazolam, fentanyl and atracurium. RESULTS: Correct positioning of the probe was easily obtained in all cases and the recording quality was excellent, whatever the operative position. Recordings of haemodynamic data showed some myocardial depression from isoflurane: decreased ABF (indexed to body surface area) and lengthened PEP/LVET (2.24 +/- 0.53 L.min-1.m-2 and 0.32 +/- 0.05 respectively, before introduction of isoflurane and 1.71 +/ 0.53 L.min-1.m-2 (P = 0.027) and 0.39 +/- 0.06 (P = 0.007) with isoflurane). CONCLUSION: These preliminary results suggest that this continuous ABF echo-Doppler device may be valuable for peri anaesthetic monitoring in infants.

Anesthesia, General↗

Overestimation of low cardiac output measured by thermodilution.

We have investigated the influence of a cold water bolus (CWB) injection on overestimation of cardiac output (CO) in low CO states in anaesthetized dogs. CO was measured using three methods: (1) thermodilution (TD), (2) electromagnetic (EM) flow meter placed on the pulmonary artery and (3) transoesophageal echo-Doppler (OD) placed on the descending aorta. Measurements of CO were obtained before (steady state) and after induction of a low CO state with thiopentone 5 mg kg-1 i.v. After CWB injection, mean CO measured by EM and OD increased by 26% and 27%, respectively (P < 0.05) during steady state, and by 85% and 75% (P < 0.05) during the low CO state. This transient increase was produced by an increase in stroke volume, while heart rate did not change. Frank Starling's law may explain this variation by a sudden increase in preload produced by CWB injection. These results indicate that thermodilution overestimated CO during low CO states when CWB injection was used.

Animals↗

[Detection of microbubbles formed in the blood/CO2 interphase during decompression in barometric conditions similar to laparoscopy].

HYPOTHESIS AND OBJECTIVES: Intraperitoneal insufflation (IPI) with CO2 during laparoscopic surgery establishes a pressure gradient that determines the passage of gas from the peritoneal cavity to the blood and surrounding tissues. The transport and clearance of CO2 are assured by proper sweeping when regional blood flow is adequate in volume and distribution. But if IPI hyperpressure surpasses regional venous capillary pressure (10 to 15 mmHg) and there is no cardio-circulatory adaptation to the phenomenon, CO2 clearance may be compromised. Under these conditions, the expected post-insufflation increase in PetCO2 will not take place. Bearing in mind the physical characteristics of CO2, retention of this gas in the intraperitoneal cavity produces blood and tissue saturation under a higher-than-atmospheric pressure, after a certain period of time in contact. Rapid intraperitoneal decompression after laparoscopic surgery carries with it the risk of microbubble formation due to release of CO2 that had been dissolved under hyperbaric conditions. MATERIAL AND METHODS: To test this hypothesis, the barometric conditions of laparoscopy were reproduced inside an observation capsule containing blood and CO2. RESULTS: Magnification revealed that after decompression bubbles formed in the blood/CO2 interphase. The images were recorded on magnetic videotape. Thirty minutes after decompression, the bubbles could still be seen, even after the interphase was swept with a current of air. DISCUSSION: Rapid intraperitoneal decompression after laparoscopy can generate the formation of microbubbles which, if not eliminated, will give rise to local ischemic manifestations. This same decompression, correcting the local circulatory alterations and activating the CO2 transport that had been compromised, could introduce gas bubbles into the blood stream such as are responsible for delayed gaseous microembolism. The simultaneous observation of changes in PetCO2 (stability or post-insufflation decreases) and hemodynamic parameters during laparoscopy, would allow evolving anomalies to be detected early and therapeutic action to be taken to prevent the formation of microbubbles.

Carbon Dioxide↗

Non-invasive continuous haemodynamic and PETCO2 monitoring during peroperative cardiac arrest.

We describe a cardiac arrest which occurred during general anaesthesia in the prone position for surgical correction of lumbar kyphosis in a patient with Marfan's syndrome. Peroperative monitoring was routine with ECG, non-invasive arterial pressure, oximetry, PETCO2 and central venous pressure, plus aortic blood flow and and systolic time intervals via an oesophageal echo-Doppler device. Forty-five minutes after the start of surgery, a sudden decrease in aortic blood flow followed by a decrease in PETCO2 suggested acute cardiac failure despite continuation of the ECG signal. Initial CPR in the prone position produced a slight increase in PETCO2. When the patient was turned to the supine position and the legs elevated, chest compression was more efficient and spontaneous circulation was rapidly restored. Circulatory arrest could be explained by incompletely treated hypovolaemia, or by myocardial depression (decrease in aortic blood flow and lengthened pre-ejection period) combined with excessive hypotension in a patient with Marfan's syndrome, thus compromising coronary blood flow producing ST segment depression. Continuous non-invasive aortic blood flow and PETCO2 monitoring proved valuable in the early detection and treatment of circulatory arrest and in the evaluation of the efficiency of peroperative CPR.

Adolescent↗

[Diagnosis of heart arrest caused by CO2 embolism during laparoscopic surgery by monitoring of aortic blood flow and capnography].

We report the case of a 25-year-old woman undergoing a laparoscopic cholecystectomy, who suffered, one min after the beginning of intraperitoneal insufflation of CO2 (2.5 L at a pressure of 10 mmHg), a sudden decrease to 0.8 L.min-1 of the aortic blood flow (ABF), monitored in the descending aorta by an oesophageal echo-Doppler probe, associated with a decrease of PetCO2 to 15 mmHg and of SpO2 readings to 88%. Despite the lack of simultaneous changes in heart rate and arterial pressure, pulmonary gas embolism (GE) was suspected. The pneumoperitoneum was exsufflated and CPR was started because of circulatory inefficiency. Ten min later, efficient spontaneous cardiac activity restarted, whereas PetCO2 and ABF returned rapidly to normal values. At this time, a typical gas noise was clearly obtained through the oesophageal Doppler transducer. The patient remained in deep coma (GCS:6) with a left sided hemiplegia. However, she fully recovered after four sessions of hyperbaric oxygenation. Simultaneous continuous monitoring of ABF and PetCO2 allows an undelayed recognition of major circulatory disturbances, before significant changes in heart rate and arterial pressure occur.

Adult↗

[Improving tissue perfusion without invasive monitoring. Apropos of a case].

A case is reported of a 64 year old patient who suffered a septic shock after surgical treatment of a biliary peritonitis. Increasing myocardial contractility and aortic blood flow by dobutamine appeared ineffective; added norepinephrine infusion improved the peripheral perfusion. This clinical improvement in tissue perfusion was evaluated by non-invasive continuous monitoring of the haemodynamic profile, combining aortic blood flow measurement by a transoesophageal echo-Doppler and continuous measurement of end-tidal carbon dioxide.

Carbon Dioxide↗

[Central venous infusion of dopamine. Changes in dose during central venous pressure measurement].

The changes in the doses of dopamine administered at a steady rate which occur during central venous pressure (CVP) measurement were studied. A workbench model with a single lumen central venous catheter was devised with which a mathematical model was constructed to calculate the alterations due to changes in different variables: central venous pressure, dopamine dose, collateral infusions. The average time for CVP measurement was 2 min. The volume of 5% glucose solution filling the manometer was 2.3 ml. The dopamine bolus generated by CVP measurement was equivalent to a dose of 85 micrograms.kg-1 x min-1. The delay required for a return to the initial dose was 2 h 42 min. Changes in CVP led to inversely proportional changes in dopamine dose. These also depended on the level to which the measuring tube was filled before carrying out the measurement. High initial rates of dopamine infusion required shorter times for a return to initial dopamine doses. The bolus and time for recovery were also inversely proportional to the volume of infusion fluids given at a steady rate on the same venous line. This model was tested in a patient suffering from bacterial pneumonia and septic shock (60 years, 55 kg). CVP measurement resulted in a bolus dose of 17 micrograms.kg-1 x min-1, leading to a 43% decrease in aortic flow rate and 60% in the ejection volume. After about 25 min, heart rate and mean arterial blood pressure had returned to their initial values, although aortic flow rate remained 30% below initial values. This problem is also met with other drugs, such as heparin.(ABSTRACT TRUNCATED AT 250 WORDS)

Catheterization, Central Venous↗

[End-tidal CO2 as a predictive index of regional perfusion and its relation to aortic flow. A clinical study during peripheral vascular surgery].

Using a new haemodynamic monitoring system, we prospectively measured the end-tidal carbon dioxide (ETCO2) and the aortic blood flow (ABF) in 7 patients undergoing major vascular surgery to evaluate the usefulness of ETCO2 as a predictive indicator of regional blood flow. Previous studies demonstrated a high correlation between ETCO2 and Cardiac Output during CPR (r = 0.79), this allows us to conclude that ETCO2, under conditions of constant ventilation, reflects the circulatory status. We investigated the relationship between ETCO2 and ABF, and our observations confirmed that the two parameters undergo highly significant variations (p < 0.001), but low correlation was found (r = 0.15), so the increase in ETCO2 after aortic declamping depended on re-perfusion of ischaemic regions. The ETCO2 concentration increased immediately in 6 patients after declamping (p < 0.05). In 1 patient, the increase wasn't significant, but he underwent a new operation because of malfunction of the prosthesis. Our findings suggest that ETCO2 monitoring may provide clinically useful information about regional perfusion that can be used to guide therapy.

Aged↗

[Transesophageal echo-Doppler in children: the importance of the exact measurement of the aortic diameter and its variations over time for estimating the aortic output].

The purpose of the study was to evaluate a new non invasive system of hemodynamic monitoring. The aortic systolic, diastolic and mean diameter have been measured with eco-TM and the aortic blood flow with pulsed Doppler, in order to obtain the aortic output. The aortic systolic diameter and the derived aortic output were then compared to the corresponding values obtained with CT. Ten healthy children were asked to be explored with CT under general anaesthesia and an oesophageal probe was positioned. The mean aortic diameter value was 7.18 +/- 0.91 mm. The systolic and diastolic aortic diameter was 7.87 +/- 0.91 mm and 6.65 +/- 1 mm respectively. The aortic systolic diameter measured with CT was 8.2 +/- 0.92 mm. Correlation analysis with aortic systolic diameter with eco TM as the dependent variable and aortic systolic diameter with CT as the independent variable revealed a highly significant correlation (r = 0.95, coefficient of determination 0.90). The mean percentage difference between systolic and diastolic diameter measured with TM eco scan was 15% with maximum variation 22% and minimum of 10% (p less than 0.003). The aortic blood flow calculated from the systolic aortic diameter was 29% higher than that obtained from diastolic aortic diameter. This would suggest that the correct measurement of the aortic diameter has to be considered in the final evaluation of aortic output especially in children in whom the elasticity of the aortic wall represents a major factor in determining fluctuations of aortic diameter.

Aorta↗

[Evaluation of tissue perfusion by simultaneous monitoring of aortic flow rate and capnography].

Ten patients under general anaesthesia were subjected to non-invasive haemodynamic monitoring, together with arterial gasometry and capnography. When enflurane was administered for maintenance anaesthesia, a 33 percent fall in aortic flow rate was observed (P less than 0.01), together with prolongation of the pre-ejection period and left ventricular pre-ejection/ejection ratio, an increase of central venous pressure and total vascular systemic resistances. The end-expiratory CO2 (Pet CO2) was reduced by 13 percent (P less than 0.05). There was no significant variation in arteriolo-alveolar CO2 difference (P(a-A)CO2). Under dobutamine (mean dose: 3.4 +/- 0.5 micrograms/kg/min), the haemodynamic parameters returned to their initial values. Pet CO2 rose above its initial level (+ 12 percent; P less than 0.05), but P(a-A)CO2 was not significantly modified. The variations of Pet CO2 were parallel with those of aortic flow rate. It is concluded that the changes in Pet CO2 observed during haemodynamic modifications could be used as markers for qualitative evaluation of tissue perfusion.

Aged↗

Assessment of a potentially noninvasive method for monitoring aortic blood flow in children.

Ultrasonic methods have rendered possible noninvasive quantitative blood flow measurement. In this work, a method is proposed to measure aortic blood flow in children by means of a specially designed miniaturized esophageal probe and an autonomous apparatus combining an M-mode imaging system and a pulsed Doppler. In vivo experimental results in animals are presented and demonstrate the interest of simultaneous and continuous measurement of aortic diameter and blood flow velocity giving accurate measurements. A 0.94 correlation coefficient is found when comparing blood flow in the descending aorta measured using this method and using an electromagnetic flowmeter.

Animals↗