Using different sets of wedges: clinical applications, dosimetry and safety interlocks.

Each accelerator is customarily supplied with one set of wedges, typically for a maximum field width of 15 cm across the wedge slope. Clinically, however, the need arises at times for larger wedged fields. Independent jaws may require wedges which are mounted at 90 degrees from a standard set, and some half-field treatment techniques may benefit from half-field wedges. To optimize treatment conditions, it is therefore desirable to have several sets of wedges available for each treatment machine. We will present clinical examples for different sets of wedges, the results of our dosimetric measurements and will discuss the required safety interlocks.

Humans↗

Impact of CT information on the treatment planning for lung tumors.

With CT information available today, the prevailing, though strong, argument for not applying lung corrections is that all clinical experience gathered so far applies to doses that were prescribed for uniform density throughout the treated volume. To ease the transition from not correcting, to the state of accounting for increased lung transmission, we have planned 10 patients: (a) in the conventional way with a wire contour obtained at simulation; target volume and critical structures were drawn in by the physician utilizing information gathered from diagnostic CT scans and X-ray films; no lung correction was applied for treatment planning. (b) For the same patients, a CT scan was obtained in treatment position and the target volume was outlined on the CT film utilizing the same information as in (a); a relative lung density of 0.3 was assigned for treatment planning. The geometric accuracy of patient outline and target volume obtained in both planning modalities is analyzed, and the intended and actually delivered tumor doses are compared when optimized treatment plans from either planning modality are selected for treatment.

Humans↗

Brachytherapy implants with differently spaced Ir-192 seeds: a dosimetric study.

Brachytherapy implantations traditionally have been carried out with continuous line sources of radium. With the popularity of afterloading implantations, iridium-192 seeds in plastic ribbons have replaced radium in the United States, although continuous sources, such as iridium wires, are widely used in Europe. The authors analyzed the impact of the use of noncontinuous sources in brachytherapy implants. Computer simulations and film dosimetry of a two-planar implant were carried out. Seeds at standard spacing (1 seed/cm), nonstandard spacing (1 seed/6mm), and continuously arranged seeds were studied.

Brachytherapy↗

Medulloblastoma therapy using electron beams.

The use of megavoltage photons for the spinal component of cerebrospinal axis irradiation is responsible for most of the long-term sequelae in children with medulloblastomas who undergo this procedure. The technique and advantages of using electrons for this component of the procedure are described.

Adolescent↗

Medulloblastoma: are we overtreating?

Modern advances in the concept and the techniques of megavoltage radiation therapy have revolutionized the treatment of medulloblastoma. Five-year survivals of 50 to 70 percent are achieved by craniospinalaxis irradiation with a boost to the posterior fossa. However, the price paid by the long-term survivors is significant. Sequelae include growth retardation, thyroid deficiency and anomalies, marrow suppression, gonadal irradiation, IQ and psychological deterioration, immunological alterations, second malignancies, and pituitary hormonal deficiencies.The literature is reviewed in terms of these sequelae and analyzed to determine optimal therapeutic doses. Although the authors agree with the doses used to treat the posterior fossa, the current doses recommended to eradicate the microscopic disease in the rest of the neuroaxis appear excessive; a lesser dose can be as effective and may decrease the rate and severity of complications.The authors believe that there is enough evidence to initiate a randomized, multi-institutional clinical trial using 20 to 25 Gy to the neuraxis (other than the posterior fossa) in one of the arms, especially when there is no evidence of tumor outside the posterior fossa.Electron beam radiation of the spinal component can decrease the dose to some of the normal structures and prevent some of the long-term sequelae.

Cerebellar Neoplasms↗

A shaping device for irregular electron fields for the Therac-20 accelerator.

A device for shaping electron fields from a Therac-20 accelerator is described. The considerable advantage of continuously variable field sizes is enhanced when the shaping device is placed on the lower trimmer bars of the shorter set of electron trimmers, which remain fully adjustable. Cerrobend blocks of 1-cm thickness are sufficient for a 5% attenuation level with 20-MeV electrons and large field sizes.

Electrons↗

The neutron dose and energy spectrum outside a 20-MV accelerator treatment room.

A maze design is discussed for a Therac 20 linear accelerator (manufactured by Atomic Energy of Canada, Ltd.) which reduces the flux of neutrons at the door to permissible levels in controlled areas. The L-shaped design allows for a relatively light door at the end of the maze, consisting of 5.08-cm (2-in.) borated polyethylene and 2-mm lead. A comparison is made between the neutron dose equivalent (DE) calculated by various methods and the DE measured with a variety of portable neutron survey meters. In addition, the neutron energy spectrum outside the maze at 1 m from the door, measured with a polyethylene multisphere LiI system, is reported.

Humans↗

Spinal axis irradiation with electrons: measurements of attenuation by the spinal processes.

Electrons may be used beneficially for spinal axis irradiation in medulloblastoma children to avoid some of the long-term sequelae induced by megavoltage photons. However, the attenuation by the intervening bone ought to be considered. Three-dimensional computer treatment planning with inhomogeneity correction for electron beams is not yet generally available, and alternate methods are needed to evaluate the attenuation by the complex bony structure of the spine. Here, we present our experimental data showing the alteration in the electron isodoses due to the intervening spinous processes. Film dosimetric measurements were made in the vertebral columns obtained from autopsies of a goat, a dog, and a child. Our results show that electron beam therapy for the spinal axis is a viable option.

Animals↗

Irradiation of the thoracic esophagus. Prone versus supine treatment positions.

A vast majority of patients with esophageal cancer receive radiation therapy for cure or palliation. Because of the close anatomic proximity of the esophagus to the spinal cord, and unusually long fields used in the irradiation of esophageal cancer, staying within the spinal cord tolerance is crucial. The present investigation shows how this can be achieved by delivering the radiation in prone position.

Esophageal Neoplasms↗