PubMed Health⌕ Search

Biomedical subjects

R Munger

Publications and source records attributed to R Munger.

At least 19 recordsLinked to original sources

Vitamin D receptor genotype and risk of osteoporotic hip fracture in elderly women of Utah: an effect modified by parity.

INTRODUCTION: The associations between vitamin D receptor (VDR) Bsm I and Fok I genotypes, parity, and risk of osteoporotic hip fracture were evaluated in a statewide population-based case-control study in Utah. METHODS: Women age 50-89 years with hip fracture (n=882) were ascertained via surveillance of 18 Utah hospitals from 1997 to 2001. Age-matched controls were randomly selected (n=897). Participants were interviewed in their homes, and blood samples were collected for genotyping. RESULTS: In logistic regression analyses that controlled for multiple confounders, Bsm I VDR genotype but not Fok I genotype was associated with risk of osteoporotic hip fracture (OR bb vs. BB genotype: 0.68; 95% CI: 0.50, 0.95). In similar analyses, no overall association was observed between parity status and risk of osteoporotic hip fracture. However, the effect of VDR genotype was modified by parity status. Among nulliparous women (n=140), Bsm I genotype was not associated with risk of hip fracture (OR bb vs. BB: 0.82; 95% CI: 0.28, 2.4); among primiparous women (n=133), bb genotype was associated with increased risk of hip fracture (OR bb vs. BB: 3.30; 95% CI: 0.96, 11.29); among multiparous women (n=1,400), bb genotype was associated with decreased risk of hip fracture (OR bb vs. BB: 0.59; 95% CI: 0.42, 0.84). CONCLUSION: VDR Bsm I genotype was associated with risk of hip fracture in Utah women, and this effect was modified by parity status. Hormonal or lifestyle factors related to parity may underlie this interaction.

Aged↗

XIAP-mediated neuroprotection in retinal ischemia.

Retinal ischemia results in the loss of vision in a number of ocular diseases including acute glaucoma, diabetic retinopathy, hypertensive retinopathy and retinal vascular occlusion. Recent studies have shown that most of the neuronal death that leads to loss of vision results from apoptosis. XIAP-mediated gene therapy has been shown to protect a number of neuronal types from apoptosis but has never been assessed in retinal neurons following ischemic-induced cell death. We injected an adeno-associated viral vector expressing XIAP or GFP into rat eyes and 6 weeks later, rendered them ischemic by raising intraocular pressure. Functional analysis revealed that XIAP-treated eyes retained larger b-wave amplitudes than GFP-treated eyes up to 4 weeks post-ischemia. The number of cells in the inner nuclear layer (INL) and the thickness of the inner retina were significantly preserved in XIAP-treated eyes compared to GFP-treated eyes. Similarly, there was no significant reduction in optic nerve axon numbers in XIAP-treated eyes. There were also significantly fewer TUNEL (TdT-dUTP terminal nick end labeling) positive cells in the INL of XIAP-treated retinas at 24 h post-ischemia. Thus, XIAP-mediated gene therapy imparts both functional and structural protection to the retina after a transient ischemic episode.

Animals↗

Regulation of nestin expression after cortical ablation in adult rat brain.

During embryogenesis, transient expression of nestin in proliferating neuroepithelial stem cells signals the commitment of progenitor cells to differentiate. Although adult mammalian brain contains very little nestin, significant upregulation of nestin has been reported following cerebral injury, leading to speculation that nestin may be involved in brain repair. In this study, we assessed the temporal profile of nestin expression following ablation injury of the sensory barrel cortex and investigated the influence of contralateral whisker stimulation on nestin expression. Since the adult mammalian brain contains proliferating neuronal progenitor cells that can be labeled with bromodeoxyuridine (BrdU), we also determined the association of nestin reexpression with BrdU-labeled cells. Nestin reexpression was detected predominantly in the ipsilateral cortex 3 days post-ablation. There was no significant nestin upregulation in the subcortical region. Nestin reexpression was most marked surrounding the lesion, but also extended throughout the entire lateral cortex. Nestin in the ipsilateral cortex subsided by day 7, although perilesional nestin expression was still apparent 28 days post-injury. Western blot analysis of nestin expression 3 days post-ablation confirmed a significant two-fold increase in nestin expression (p<0.05). Double immunofluorescence labeling demonstrated that the majority of nestin expression occurred in astrocytes. We were unable to detect any colocalization with neuronal makers. However, BrdU-labeled cells, which were readily detected in the subventricular zone prior to injury, were readily detected in the perilesional area 3 days post-ablation, concomitant with nestin in this area. Confocal microscopy detected several BrdU-positive cells expressing nestin. Taken together, the data support a potential role for nestin reexpression in brain repair.

Animals↗

A collagen-based scaffold for a tissue engineered human cornea: physical and physiological properties.

Stabilized collagen-glycosaminoglycan scaffolds for tissue engineered human corneas were characterized. Hydrated matrices were constructed by blending type I collagen with chondroitin sulphates (CS), with glutaraldehyde crosslinking. A corneal keratocyte cell line was added to the scaffolds with or without corneal epithelial and endothelial cells. Constructs were grown with or without ascorbic acid. Wound-healing was evaluated in chemical-treated constructs. Native, noncrosslinked gels were soft with limited longevity. Crosslinking strengthened the matrix yet permitted cell growth. CS addition increased transparency. Keratocytes grown within the matrix had higher frequencies of K+ channel expression than keratocytes grown on plastic. Ascorbic acid increased uncrosslinked matrix degradation in the presence of keratocytes, while it enhanced keratocyte growth and endogenous collagen synthesis in crosslinked matrices. Wounded constructs showed recovery from exposure to chemical irritants. In conclusion, this study demonstrates that our engineered, stabilized matrix is well-suited to function as an in vitro corneal stroma.

Animals↗

Changes in measured intraocular pressure after hyperopic photorefractive keratectomy.

PURPOSE: To investigate the effect of hyperopic photorefractive keratectomy (PRK) on intraocular pressure (IOP) measurements. SETTING: University of Ottawa Eye Institute, Ottawa Hospital, Ottawa, Canada. METHODS: In this retrospective cohort study, IOP and central corneal thickness (CCT) were measured preoperatively and at 1, 2, 3, 6, 12, 18, and 24 months in 191 eyes that had hyperopic PRK with the VISX Star excimer laser. All corrections applied were between +1.00 and +6.50 diopters (D) of sphere and less than 3.75 D of cylinder. RESULTS: At all postoperative examinations, the mean IOP in the hyperopic PRK group was 1.0 to 1.8 mm Hg lower than the preoperative IOP (P <.001). A large range of IOP changes was found across the population; eg, at 6 months, 49% of the eyes had a change in IOP from baseline of at least +/-3 mm Hg. A mean reduction of 19 microm of CCT was found with pachymetry after surgery (P < .001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or applied correction. Changes in IOP were strongly correlated with preoperative IOP at all time points and with preoperative CCT at 18 and 24 months (P < .001). After hyperopic PRK, the measured IOP was more likely to increase in patients with preoperative IOPs less than 14.5 mm Hg and more likely to decrease in patients with preoperative IOPs above 14.5 mm Hg. CONCLUSION: Changes in IOP after hyperopic PRK were similar to changes after myopic PRK, despite only minimal changes in the CCT. This suggests that hyperopic PRK results in biomechanical effects that modify the elastic properties of the cornea beyond the changes in rigidity expected from central corneal thinning. There was a strong negative correlation between the measured preoperative IOP and the change in IOP postoperatively that was likely the result of regression of the mean effect.

Cohort Studies↗

Acute hyperinsulinemia and very-low-density and low-density lipoprotein subfractions in obese subjects.

BACKGROUND: The influence of hyperinsulinemia on concentrations of lipoprotein subfractions in obese, nondiabetic persons has not been clarified. OBJECTIVE: We analyzed VLDL and LDL subfractions before and after a euglycemic, hyperinsulinemic clamp. DESIGN: Lipoprotein subfractions were isolated from plasma samples obtained in the basal state and after a 4-h clamp from obese patients, obese patients with type 2 diabetes, and nonobese control subjects. RESULTS: Hyperinsulinemia tended to reduce concentrations (&xmacr;: 20%) of large, triacylglycerol-rich VLDL(1) in obese patients but had a minor effect on VLDL(2) and VLDL(3). Placing obese patients into insulin-sensitive and insulin-resistant subgroups revealed distinct effects of the degree of insulin sensitivity on VLDL. VLDL(1) concentrations decreased by a mean of 38% (P < 0.05) in insulin-sensitive patients after the clamp, similar to but less marked than the decrease observed in control subjects (&xmacr;: 62%; P < 0.01). VLDL(1) concentrations did not change significantly after the clamp in insulin-resistant patients (and patients with type 2 diabetes), whereas VLDL(3) concentrations decreased in both groups, in contrast with the changes seen in the insulin-sensitive patients and control subjects. Acute hyperinsulinemia modified the LDL subfraction profile toward a greater prevalence of small, dense LDLs in insulin-resistant patients and patients with type 2 diabetes. CONCLUSIONS: Insulin resistance appears to be the primary determinant of the modifications to VLDL subfraction concentrations. Our results suggest a continuum of impaired insulin action on VLDL, ranging from that in healthy persons to that in patients with type 2 diabetes, in which obese patients occupy a transition state. Insulin resistance may also play a role in detrimental modifications to the LDL profile by allowing the development of hypertriglyceridemia.

Adult↗

Functional human corneal equivalents constructed from cell lines.

Human corneal equivalents comprising the three main layers of the cornea (epithelium, stroma, and endothelium) were constructed. Each cellular layer was fabricated from immortalized human corneal cells that were screened for use on the basis of morphological, biochemical, and electrophysiological similarity to their natural counterparts. The resulting corneal equivalents mimicked human corneas in key physical and physiological functions, including morphology, biochemical marker expression, transparency, ion and fluid transport, and gene expression. Morphological and functional equivalents to human corneas that can be produced in vitro have immediate applications in toxicity and drug efficacy testing, and form the basis for future development of implantable tissues.

Animal Testing Alternatives↗

Positive correlation between Tono-Pen intraocular pressure and central corneal thickness.

OBJECTIVE: To examine the relationship between intraocular pressure (IOP) readings taken by the Tono-Pen tonometer (Mentor O&O, Norwell, MA) and central corneal thickness (CCT). DESIGN: Prospective cross-sectional population study. PARTICIPANTS: There were 651 eyes of 332 healthy subjects. MAIN OUTCOME MEASURES: A questionnaire was given to each subject requesting information on gender, age, race, and other factors that can influence IOP. The IOP then was measured using the Tono-Pen followed by measurements of CCT using an ultrasonic pachymeter. RESULTS: The IOP was found to increase by 2.9 mmHg/100 microns CCT in males and 1.2 mmHg/100 microns in females. For males, CCT was found to be statistically significant in predicting IOP (P < 0.001 in the right and left eyes) and diabetes was of borderline significance (P = 0.012 in the right eye, P = 0.089 in the left eye). For females, CCT was of borderline significance (P = 0.064 in the right eye, P = 0.019 in the left eye). In females, a family history of glaucoma (P = 0.021 in the right eye, P = 0.022 in the left eye) and hypertension (P = 0.010 in the right eye, P = < 0.001 in the left eye) were also significant in the prediction of IOP. Race was found to be a significant predictor of CCT (P < 0.001 in both right and left eyes) for both males and females. CONCLUSION: Clinicians should be aware that, as with the Goldmann applanation tonometer, the Tono-Pen has a systematic error in IOP readings caused by its dependence on CCT. Tono-Pen IOP readings are positively correlated to CCT in males and, to a lesser extent, in females as well. The CCT measurements should be considered to ensure proper interpretation of IOP measurements in the diagnosis and management of disorders in which the CCT or IOP readings are outside normal limits.

Adult↗

Comparative study of the elevation topography of complex shapes.

PURPOSE: To compare the accuracy and precision of the elevation topography from two commercially available instruments using videokeratoscopy or rasterstereography. SETTING: University of Ottawa Eye Institute, Ottawa General Hospital, Ontario, Canada. METHODS: Repeated measurements of elevation topography of six calibrated surfaces were done with the PAR Corneal Topography System (CTS) and the Tomey Topographic Modeling System (TMS-1). The shapes simulated normal (A: aspheric, B: spherocylindric) and postsurgical corneas (C: hyperopic, D: myopic, E: central island, F: phototherapeutic keratectomy). Surface shapes were described by parametric equations. Equation parameters associated with each elevation measurement were determined by best-fit analysis. Measurement precision was assessed by the standard deviation of the difference between the fitted and the measured data. Fitted parameters were compared with nominal values obtained from an independent calibration of each surface. The root mean square error (RMSE) of the deviation of the fitted from the nominal surfaces was used to evaluate the accuracy of each instrument. RESULTS: The accuracy of the CTS exceeded that of the TMS-1 for all surfaces measured. The RMSE values (micron) were (A: 0.1, 6.5), (B: 0.3, 3.8), (C: 1.1, 11.8), (D: 5.0, 43.0), (E: 1.2, 3.2) and (F: 2.2, 17.5) for the CTS and TMS-1, respectively. The differences in the measured data from the fit surface were generally smaller with the TMS-1. CONCLUSION: Quantitative analysis of elevation measurements showed that the CTS represented surface topography more accurately than the TMS-1.

Cornea↗

Correction of intraocular pressure for changes in central corneal thickness following photorefractive keratectomy.

OBJECTIVE: To investigate the relation between measurements of intraocular pressure (IOP) and central corneal thickness (CCT) in myopic patients undergoing photorefractive keratectomy (PRK). DESIGN: Descriptive study. SETTING: University-affiliated eye care centre in Ottawa. PATIENTS: A total of 481 consecutive eyes of 318 patients with a mean preoperative refractive error of -6.50 dioptres treated with excimer PRK between March 1993 and December 1996. OUTCOME MEASURES: IOP measured by Goldmann applanation tonometry and CCT before and 3, 6, 12, 18 and 24 months after surgery. RESULTS: CCT was a significant predictor of IOP only before PRK and 6 months after PRK (p < or = 0.05). The relation between IOP and CCT suggests corrections for CCT that are not clinically significant (0.81 mm Hg [standard error (SE) 0.33 mm Hg] and 1.00 mm Hg [SE 0.38 mm Hg] per 100 microns of corneal thinning preoperatively and at 6 months respectively). On average, there was a significant decrease in IOP after PRK (0.96 mm Hg and 1.24 mm Hg at 12 and 24 months respectively) (p < 0.05). There was a significant correlation between change in IOP and change in CCT (decrease of 2.1 mm Hg per 100 microns of corneal thinning) (p < 0.05). For a given change in CCT, individual changes in IOP were variable, with increases or decreases of more than 5 mm Hg in some cases. CONCLUSIONS: There are individual differences in IOP changes following PRK. Until further data are available we propose that the change in IOP between the preoperative visit (or the fellow eye, if healthy or untreated) and the 12-month visit be used as an individual correction factor to be applied to IOP measurements in the operated eye.

Adolescent↗