PubMed Health⌕ Search

Biomedical subjects

R Novario

Publications and source records attributed to R Novario.

18 recordsLinked to original sources

Radiochromic film measurement of anisotropy function for high-dose-rate Ir-192 brachytherapy source.

The dose distribution produced by the high-dose-rate (HDR) 192Ir source is inherently anisotropic due to self-absorption by the high-density source core, oblique filtration by the source capsule and the asymmetric geometry of the source capsule. To account for the dose distribution anisotropy of brachytherapy sources, AAPM Task Group No 43 has included a two-dimensional anisotropy function, F(r, theta), in the recommended dose calculation formalism. Gafchromic HS radiochromic film (RCF) was used to measure anisotropy function for microSelectron HDR 192Ir source (classic/old design). Measurements were carried out in a water phantom using specially fabricated PMMA cylinders at radial distances 1, 2, 3, 4 and 5 cm. The data so generated are comparable to both experimental and Monte Carlo calculated values for this source reported earlier by other authors. The RCF method described in this paper is comparatively high resolution, simple to use and is a general method, which can be applied for other brachytherapy sources as well.

Algorithms↗

Microvessel density in prostate carcinoma.

The objective of this work was to assess the correlation between microvessel density (MVD), pathological stage and disease recurrence in a series of patients who underwent radical prostatectomy for prostate cancer. Pathological material from 75 consecutive radical prostatectomies performed before 1994 without neo-adjuvant treatment, in which sufficient follow-up data were available, was re-examined. Paraffin embedded material was re-cut and hematoxylin and eosin (H&E) stained. Areas of maximal angiogenesis within tumor were identified. Expression of CD34 was investigated by using the monoclonal antibody MY 10. Within the areas of maximal angiogenesis, microvessels expressing CD34 were counted and specimens were divided into two groups, one showing a count of less than 90 microvessels per microscopic field at 200 x magnification (MVD<90), the second more than 90 microvessels (MVD>90). The MVD was then related to pathological stage, Gleason score (GS) and outcome of the disease. Mean follow-up was 84 months. Clinical or biochemical progression was observed in 38.6% of patients. In low GS cases, MVD was always <90, whereas in GS 5-6, half had MVD <90 and half were >90. In high GS MVD was always >90. MVD was positively associated with a higher pathological stage. Progression of the disease was observed in 20% of MVD <90 and in 51% in MVD >90 (P=0.006). Mantel-Haensz test showed a correlation between MVD and time to progression (P<0.05). Although problems exist in methods of counting and in the cut-off number of vessels, which can discriminate the risk categories, it may be concluded that microvessel counts, using CD34 monoclonal antibody, can accurately predict the outcome of radical prostatectomy.

Antibodies, Monoclonal↗

Patient effective dose from endovascular brachytherapy with 192Ir sources.

The growing use of endovascular brachytherapy has been accompanied by the publication of a large number of studies in several fields, but few studies on patient dose have been found in the literature. Moreover, these studies were carried out on the basis of Monte Carlo simulation. The aim of the present study was to estimate the effective dose to the patient undergoing endovascular brachytherapy treatment with 112Ir sources, by means of experimental measurements. Two standard treatments were taken into account: an endovascular brachytherapy of the coronary artery corresponding to the activity x time product of 184 GBq.min and an endovascular brachytherapy of the renal artery (898 GBq.min). Experimental assessment was accomplished by thermoluminescence dosemeters positioned in more than 300 measurement points in a properly adapted Rqndo phantom. A method has been developed to estimate the mean organ doses for all tissues and organs concerned in order to calculate the effective dose associated with intravascular brachytherapy. The normalised organ doses resulting from cronary treatment were 2.4 x 10(-2) mSv.GBq(-1).min(-1) for lung, 0.9 x 10(-2) mSv.GBSq(-1).min(-1) for oesophagus and 0.48 x 10(-2) mS.GBq(-1).min(-1) for bone marrow. During brachytherapy of the renal artery, the corresponding normalised doses were 4.2 x 10(-2) mS.GBq(-1).min(-1) for colon, 7.8 x 10(-2) mSv.GBq(-1).min(-1) for stomach and 1.7 x 10(-2) mSv.GBq(-1).min(-1) for liver. Coronary treatment iJnvlled an efl'fective dose of (0.046 mSv.GBq(-1).min(-1), whereas the treatment of the renal artery resulted in an effective dose of 0.15 mSv.GBq(-1).min(-1); there were many similarities with data from former studies. Based on these results it can be concluded that the dose level of patients exposed during brachytherapy treatment is low.

Arteries↗

A new method to assess the fluidodynamic behaviour of an angiographic contrast agent.

PURPOSE: To propose a new method for the assessment of the fluidodynamic behaviour of angiographic contrast agents. The method enables measurement of the spatial distribution and time dependence of the contrast agent along a pseudo-vessel on images obtained with an X-ray image intensifier. MATERIAL AND METHODS: A particular phantom was devised consisting of a plexiglas box with an insert into which a latex tube with a 0.4 cm in diameter was placed in order to simulate the tortuous flow of a blood vessel. The box, which is filled with water to simulate the thickness of a normal patient, is connected to an injection and pumping system which serve to keep the contrast agent flowing in the pseudo-vessel tube. The pseudo-vessel tube was filled with plain water in one case and with saline solution in another case to assess their different dilution capabilities. The phantom and the flow of contrast agent were imaged with a conventional X-ray image intensifier system and the images were stored in digital format during 35 second acquisitions at a speed of 4 frames per second; for any frame it is possible to measure the mathematical contrast in any position in the image. Further, a diagram showing the time dependence of the spatial distribution of the mathematical contrast is proposed. The X axis shows the spatial distribution of the mathematical contrast, whereas the Y axis shows its temporal variation with a gray level proportional to the mathematical contrast value. By building an horizontal profile of this diagram one can obtain the spatial distribution at a fixed time, while by building a vertical profile one can obtain the temporal variation at a fixed point. Several different contrast agents were so tested. RESULTS: The proposed method allows different fluido-dynamic behaviour patterns of contrast agents and flowing media to be shown. Owing to the different chemical characteristics of water and saline solution these media have different dilution capabilities (higher for water) and this is well demonstrated by the diagram profiles obtained for each. The system has also allowed the detection of a particular behaviour of some contrast agents, whose spatial distribution was non uniform even in the last frames, thus showing a tendency to maintain their bolus-nature over time. An interesting feature which can be noticed in all the temporal profiles is the presence of a "pre-bolus", i.e. the contrast is higher at the very beginning of the flow, then decreases and after some time starts to increase again. Though the initial contrast value obviously depends on the iodine concentration employed, the method shows the contrast variation as a function of time is different for different contrast agents. CONCLUSIONS: The method and the equipment proposed provide a good description of the fluidodynamic behaviour of different contrast agents, but do not constitute a reference method for testing haemodynamic behaviour which, "in vivo", is obviously affected by several other chemical and metabolic factors. However, the method allows evaluation of the contrast agents from a physical and fluidodynamic point of view, showing that the iodine content is not the only feature affecting their behaviour. The method can be used in quality control to test the constancy of the physical behaviour of different contrast agents.

Angiography↗

[Feasibility of the use of elastographic techniques with ultrasound in the diferentiation of different tissues].

PURPOSE: To investigate the feasibility of distinguishing different tissues by detecting their different elastic properties when mechanically stimulated with an ultrasound wide beam. MATERIAL AND METHODS: A tissue-mimicking material phantom was placed in a water filled box. Two devices (Teuco Hydrosonic) emitting two US beams (3.2 MHz) were placed on two opposite walls of the box. The US beams had a circular diameter of about 10 cm; their intensity could be set by varying the power voltage applied to the device from 0 to 12 V. The US beams caused a mechanical stimulation of both the phantom and the water surrounding it. An ATL HDI 5000 scanner was used in order to acquire tissue Color Doppler images using the fundamental frequency (Tissue Doppler Imaging, TDI), and the second harmonic (Harmonic Tissue Doppler Imaging, HTDI). The images allowed to visualize, using a color scale, the vibrational status of both the phantom and the water surrounding it. Both fundamental and second harmonic images were taken using different power values supplied to the stimulation device, with the voltage ranging from 0 to 12 V. In order to quantify the vibrational status of the water and of the tissue-mimicking phantom two Regions Of Interest (ROI) were taken on the images. A parameter describing the "color amount" in each ROI and defined by an appropriate mathematical function was proposed. RESULTS: Differences between the values of the "color amount" parameter in the phantom and in water were statistically significant both at the fundamental frequency and at second harmonic imaging, and for each positive value of the voltage of the power supplied to the device for the stimulation. Also the differences between the parameter "color amount" at the fundamental frequency and second harmonic imaging were statistically significant; the differences were found for both water and phantom and for any positive voltage. The correlation between the intensity of the stimulation (voltage) and the "color amount" parameter is statistically significant with the second harmonic technique in the phantom, nearly significant with the second harmonic technique in water and not significant in the other cases. CONCLUSIONS: It is possible to try to characterize a tissue by analyzing its elastic properties when an ultrasound wide beam mechanically stimulates it. The most promising technique consists in acquiring images using Harmonic Tissue Doppler Imaging, (HTDI) and measuring the vibrational status by using the "color amount" parameter proposed.

Elasticity↗

[Study of ultrasonographic image textures with second-order statistical methods].

BACKGROUND: We report the sonographic image texture of the neonatal heart in different stages of development by calculating numerical parameters extracted from the gray scale cooccurrence matrix. To show pixel values differences and enhance texture structure, images were equalized, and then the gray level range was reduced to 16 to allow for sufficiently high occupancy frequency of the cooccurrence matrix. MATERIALS AND METHODS: We measured B-mode US images, all acquired with the same unit, using the same setup (gain, frequency, constant TGC). For each case measurements were made on 3 diastolic images by selecting a 32 x 64 pixel on the interventricular septum ROI. This procedure was applied to 3 different examinations made at birth, at 3 days, and after a month of life. For each 8 bit image we obtained a coocurrence matrix by sampling adjacent pixels at 0 degree, from which we calculated entropy; then the images were equalized and converted to 4 bit format; on these processed images we calculated 4 gray scale coocurrence matrix samplings adjacent pixels at angles of 0 degree, 45 degrees, 90 degrees, and 180 degrees. Parameters obtained from different angles cooccurrence matrix were averaged to get a numerical parameter independent of sampling angles. RESULTS: The one-way analysis of variance and Student's "t"-test were performed on the parameters obtained from 3 different examinations and the differences among different developmental stages are 95% significant. No significance was obtained comparing images at birth with those at 3 days. CONCLUSIONS: Differences are so little significant that they may be due to different factors affecting image texture and the variability introduced by manual ROI positioning; therefore no definitive conclusions can be drawn as to considering this kind of analysis capable of discriminating different stages of myocardial development. To apply this analysis to routine US examinations, different correction factors for range, azimuth, and focal dependence of texture must be considered.

Mathematics↗

[A method of image enhancement in the use of hydrosoluble uro-angiographic contrast media].

The radiographic contrast, when using hydrosoluble uro-angiographic contrast media, depends on several factors. A phantom and a new method are proposed to assess and optimize the contrast. The phantom allows to simulate three pseudovessels with diameter of 2 mm, 5 mm, and 10 mm, placed in a water-equivalent layer of 20/cm thickness. The phantom is exposed to a photon beam produced by a conventional X ray tube, and the images are obtained using conventional screen film system. The aim of the study is to assess the radiographic contrast between the vessel and the background when modifying the optical density of the radiograph (by different settings of the mAs switching), the X-ray tube high voltage and the diameter of the vessels; the contrast was studied with four different contrast media (Uromiro 24%, Conray 36%, Iopamiro 300 and Iomeron 400) and three X-ray tube high voltages (60 kV, 80 kV, 100 kV). The curve fitting the contrast as a function of the optical density of the background (in each condition of high voltage, diameter of the vessel and contrast media used) is a parabola. A quite narrow distribution of abscissas of the maxima of the parabolas was found, ranging from the minimum optical density 1.21 in the case of 100 kV high voltage and 2 mm diameter to the maximum optical density 1.58 in the case 60 kV and 10 mm. The mean value (1.40) is proposed as the optical density of the background optimizing the contrast according to the screen-film system used. In conclusion, the authors suggest to optimize the use of contrast media, trying to obtain radiographs with an optical density approaching the optimal value in any clinical situation. Therefore tables of the settings of the X-ray tube and generator are required; the tables must take into account the main parameters influencing the settings, such as the source-film distance, the water-equivalent thickness of the patient and the film-screen system used.

Angiography↗

The choice of radiographic film-screen systems: quality evaluation and purchasing specifications drafting. Report on A.I.F.B. Working Group activity.

The comparative evaluation of radiographic screen-film systems presents several problems from both the theoretical and the experimental points of view. From the theoretical point of view the main difficulties are related to the choice of the parameters best suited to express the "overall quality" of a system. This quantity is expressed as a product of image quality index and system sensitivity. As image quality index we assumed the signal-to-noise power ratio: this index depends in an explicit way on contrast, resolution and noise of the system. From the experimental point of view the main problem is that to measure some basic quantities, sophisticated and expensive equipment, like computer-controlled microdensitometers, is generally required. In this paper, we report the Italian Association of Biomedical Physicists Task group suggestions for measuring the basic physical parameters (with particular reference to the use of cost-effective equipment and for purchasing specification drafting). Using synthetic quality indices, the evaluation criteria of radiographic materials are directly derived from the general theory of radiographic image perception.

Physical Phenomena↗

A new method for calculating the distribution of radioactivity in man measured with a whole-body counter.

A whole-body counter with a scanning bed and two opposite (antero-posterior) probes was used to obtain profiles of count rates of radioactivity held in the whole body. The distribution of the activity in the patient was calculated by solving an overdetermined system (more equations than unknowns) of linear equations with the Chebyshev method, the least-squares method, and an iterative method. The iterative method gave the best results, especially in the case of distributions with peaks of radioactivity. Some in-vivo applications of the method are presented.

Diphosphonates↗

[Total skin irradiation with electrons for mycosis fungoides: criteria for the choice of technique and experimental dosimetry].

The initial lesions of mycosis fungoides are confined to the skin at a depth of about 1 cm. Wide fields irradiation with low energy electron beams is therefore the treatment of choice for the first stages of the disease. The authors have analysed the various treatment techniques of total skin electron beam irradiation reported in the literature. Dosimetric and practical features are considered. The angled beams technique seems to fit better the needs of a common Radiation Therapy Department. A treatment system with six pairs of 3 MeV electron beams is described and preliminary dosimetric measurements of a similar system that employs 6 MeV electrons are reported.

Electrons↗

Natural history and treatment of uremia secondary to Fabry's disease: an European experience.

Fabry's disease, a very unusual cause of end-stage renal disease, is actually included in the contraindications to renal transplantation. The few published studies, based on very few patients, report a high rate of life-threatening complications, mostly infectious, following kidney transplant in these patients. We have evaluated retrospectively 12 uremic patients in renal function replacement treatment for Fabry's disease. In transplanted patients (n = 8; whole observation period 241 months), no lethal complication was ever recorded. Fever and acroparesthesias ameliorated. Cardio- and cerebrovascular complications did not progress. Although no increase in serum enzymatic activity was measured, renal transplantation provided an alternative route by excretion of an amount of the metabolic product (ceramide-trihexoside). When undergoing maintenance hemodialysis (whole observation period 291 months), 3 deaths and several cardiac and cerebral complications occurred. Angiokeratomas, fever and pains were unmodified. These data disagree with what has been previously stated. The transplanted patients' survival shifts towards the all-time rate and a satisfying rehabilitation is provided. Fabry's disease should not be considered a high-risk disease; and patients suffering from it should decidedly enter a regular transplantation program.

Adolescent↗

[The management of particle accelerators in radiotherapy].

In this multicentric survey, the management costs and the technical problems connected with the use of electron accelerators in Radiotherapy are studied. The data were collected by a proper questionnaire and concern 11/35 accelerators in use in Italy, in public hospitals, during the period 1982-1983. The average purchase cost of an accelerator was 1113 milions lire and the amortization cost is 111 milions lire per year. The expenses for the amortization of the cost of the bunker, for ordinary and extraordinary maintenance, for the employed staff and for the electric power respectively, represent the 22%, 5%, 43% and 2% of the total management cost (395 milions lire per year). In 1983 the load per machine was 400 patients and the cost per patient was 1 milion lire. On the average, 4 years are needed from the order to the beginning of the treatments with large differences among centers. The machines average use is 7.1 hours a day and keep 2.8 technicians busy per week. The time wasted by repairs or maintenances increases (+7%) the average duration of stay in hospital of patients. An attentive evaluation of the studied parameters allows us to single out the most significant variables on which is possible to work to increase the efficiency and to reduce the management costs of an accelerator.

Cost-Benefit Analysis↗

Radiotherapy treatment verification.

During a radiotherapy treatment, a dosimetric verification or a geometric localization can be done, in order to assess the quality of the treatment. The dosimetric verification is generally performed measuring the dose at some points inside (natural cavities) or outside the patient, and comparing it to the dose at the same points calculated and predicted by the treatment planning system. This can be done either with thermoluminescent or diodes dosimeters or with ionization chambers. The geometric localization can be done acquiring a portal image of the patient. Portal imaging can be performed either with films placed between metallic screens, or with an electronic portal imaging device such as fluoroscopic systems, solid state devices or matrix ionization chamber systems. In order to assess possible field placement errors, the portal images have to be compared with images obtained with the simulator in the same geometric conditions and/or with the digitally reconstructed radiograph (DRR) obtained with the treatment planning system. In particular, when using matrix ionization chamber systems, the portal images contain also information regarding the exit dose. This means that this kind of imaging device can be used both for geometric localization and for dosimetric verification. In this case, the exit dose measured by the portal image can be compared with the exit dose calculated and predicted by the treatment planning system. Some "in-vivo" applications of this methodology are presented.

Humans↗

Immunoassay of neuron-specific enolase (NSE) and serum fragments of cytokeratin 19 (CYFRA 21.1) as tumor markers in small cell lung cancer: clinical evaluation and biological hypothesis.

NSE is a biochemical marker for small cell lung cancer (SCLC) diagnosis and management. CYFRA 21.1 is a newly developed immunoassay to detect the serum fragments of cytokeratin 19 which are also expressed in SCLC with or without neurofilaments. The aim of this study was to evaluate the diagnostic performance and prognostic role of the two markers in SCLC and their contribution to chemotherapy monitoring and patient follow-up. We studied 62 patients with pathologically proven SCLC: 28 with limited disease (LD) and 34 with extensive disease (ED), and 100 patients with non-malignant pulmonary disease. Immunoradiometric assays (IRMA) were employed to test NSE and CYFRA 21.1 in patients and control subjects. For each patient subset results were expressed as median and interquartile distribution range. NSE and CYFRA 21.1 sensitivity was 0.52 (33/62) and 0.56 (35/62), respectively. In the group of patients with LD, NSE and CYFRA 21.1 sensitivity was 0.42 (12/28) and 0.54 (15/28) and in patients with ED, NSE and CYFRA 21.1 were positive in 0.62 (21/34) and 0.59 (20/34) of cases, respectively. Combining the two markers, a sensitivity of 0.78 (22/28) in LD, 0.82 (28/34) in ED and a global sensitivity of 0.80 (50/62) was obtained. Only NSE was significantly linked to the extension of disease (Mann-Whitney U test p = 0.002) while CYFRA 21.1 did not correlate. The analysis of survival and the evaluation of the two markers at diagnosis showed CYFRA 21.1 to be strongly linked to the patients' outcome, independently of both clinical prognostic factors and NSE levels (log rank and Cox's model). The markers' performance during chemotherapy was tested in a group of 33 patients with at least one marker above cut-off. NSE can be considered a reliable marker of tumor mass modifications under chemotherapy, while CYFRA 21.1 expression seems to be relatively independent of tumor volume modifications. An applicable model of biomarkers in SCLC could be the concurrent assay of NSE and CYFRA 21.1 in pre-therapeutic assessment and therapy planning. CYFRA 21.1 does not play an important role during therapy monitoring and follow-up; in these phases NSE alone may be employed.

Antigens, Neoplasm↗

Primary gastric non-Hodgkin's lymphoma in a population-based registry.

BACKGROUND: The incidence of primary gastric non-Hodgkin's lymphoma (NHL) appears to have increased worldwide in recent years, and this seems to be confirmed by large-sample population studies. METHODS AND RESULTS: We derived our data from the Lombardy Cancer Registry, which provides the incidence of cancer in the province of Varese, Northern Italy. From 1978 to 1987 we identified 3261 cases of gastric neoplasms, 119 of which were gastric NHL: 32 (1.87%) from 1978 to 1982, and 87 (5.32%) from 1983 to 1987. The difference in the age and sex standardized incidence trend between these two time periods was statistically significant (p < 0.001). The overall survival rate of the 112 evaluable patients was 54% at 5 years and 45% at 10 years. A multivariate analysis was performed. Age (p < 0.0005), clinical stage (p < 0.04) and therapy (p < 0.0005) were found to be significant prognostic factors for survival. CONCLUSIONS: This study stresses the utility of prospective randomized clinical trials that could indicate the optimal management of patients with primary gastric lymphoma.

Adult↗

[Study of intestinal absorption of calcium using 47Ca and whole body counter in renal calculosis with hypercalciuria].

Intestinal calcium absorption was studied using orally administered 47Ca and whole body counting. Using this method, we examined 82 patients suffering from recurrent calcium urolithiasis associated with idiopathic hypercalciuria, to evaluate the incidence of elevated intestinal absorption of this ion. An oral dose of 111 kBq (3 microCi) of 47Ca chloride, together with 250 mg of stable calcium as carrier, was given to each patient. Two hours and one week later, the total body radioactivity of each subject was measured. The retention of 47Ca, as percentage of the administered dose, was then calculated. The measurements were performed with a whole body counter consisting of a two-crystal moving system with shadow shield. Forty age-matched healthy volunteers were also examined. The whole body retention of 47Ca resulted significantly higher (p less than 0.0002) in the group of patients than in the control sample, whose m +/- SD was 22.0 +/- 6.0%. In particular, by defining the normality range as 10-34% (m +/- 2SD of control results), enhanced intestinal absorption of calcium was found in 28% of the examined patients. The use of this simple examination seems to be helpful in the physiopathologic assessment of subjects suffering from calcium urolithiasis and idiopathic hypercalciuria and consequently, in their appropriate management.

Adolescent↗

[Management of electron accelerators for radiotherapy. Data as of 31 December 1984].

Several italian radiotherapeutic centers have supplied the data analysed, regarding problems connected with the management of electron accelerators in the years 1982-1983-1984. The data concern 27 out of the 35 accelerators settled in Italy. The average cost of purchase has proved to be of 940 M pounds with an expense of annual allowance of 94 M pounds. We have then analysed the incidences of the allowance of the purchase expenditure of the machine (23%), the allowance of the expenses for the construction of the bunker (22%), the expenses of maintenance of the machine (5%), the cost of the staff (48%) and the cost of the power supply (2%) on the management costs (about pounds 820.000 per each handled patient). The duration of the various phases of the machinery installment, from the purchase to the beginning of the treatment, the charge of work supported in the three considered years, the daily use of the machinery and the problems deriving from days of time out of services due to failures or to periodical maintenance have then been studied. The analysis of the average values of the parameters studied and of the range of their variability allows us to find out the sector in which it is possible, also at present, to intervene in order to ameliorate the employment of a linear accelerator, regarding the costs and the performance.

Cost-Benefit Analysis↗