PubMed Health⌕ Search

Biomedical subjects

R P Dai

Publications and source records attributed to R P Dai.

At least 19 recordsLinked to original sources

Differential expression of cytokines in the rat heart in response to sustained volume overload.

OBJECTIVE: The present study aimed to investigate whether sustained volume overload is capable of inducing persistent upregulation of cardiac cytokines including tumor necrosis factor alpha (TNF)-alpha, interleukin (IL)-1beta, interleukin (IL)-6 and transforming growth factor (TGF)-beta(1). METHODS AND RESULTS: Volume overload-induced heart hypertrophy in rats was established by aortacaval fistula, and the cardiac cytokines were measured in the myocardium from 1 to 4 weeks after operation. In the post-fistula rats, cardiac IL-1beta and IL-6 gene and protein levels were upregulated throughout the time of measurement. Immunohistochemistry demonstrated that IL-1beta and IL-6 immunoreactive cells were widely distributed in the myocardium in the earlier time intervals, and mainly localized in the regions close to the endocardium in the later time intervals. The cardiac IL-1beta immunoreactive cells were mainly localized in the blood vessels whereas the IL-6 positive cells were composed of non-myocytes and cardiomyocytes. TGF-beta(1) positive staining was increased in the myocardium up to 3 weeks after aortacaval fistula and then decreased to basal levels thereafter. In contrast to the activation of cardiac IL-1beta and IL-6 in response to volume overload, TNF-alpha expression appeared unaltered in response to sustained volume overload in the transcription and protein levels. CONCLUSION: The results of the present study indicate that sustained volume overload is capable of inducing persistent upregulation of some cardiac cytokines. In addition, the differential expressions of TNF-alpha, IL-1beta and IL-6 suggest that the induction of IL-6 and IL-1beta is independent of TNF-alpha mediated pathways in this animal model.

Animals↗

Induction of cytokine expression in rat post-ischemic sinoatrial node (SAN).

The aim of this study was to determine the spatial and temporal expression of various pro-inflammatory cytokines in the peri-sinoatrial nodal area after atrial infarction. Rats were subjected to permanent atrial infarction, in particular, sinoatrial node (SAN) infarction and sacrificed at various time points up to 7 days. Real-time polymerase chain reaction analysis demonstrated that mRNA levels of tumor necrosis factor alpha (TNF-alpha), interleukin-1beta, interleukin-6, and transforming growth factor beta 1 (TGF-beta(1)) were upregulated in the peri-sinoatrial nodal area after atrial infarction. Immunostaining for TNF-alpha and TGF-beta(1) proteins revealed that both cytokines were expressed persistently up to 7 days after atrial infarction around the peri-sinoatrial nodal area. Furthermore, the infiltrating inflammatory cells immunoreactive for both cytokines were predominant within the infarct SAN. In situ hybridization analysis showed that TNF-alpha gene expression was enhanced in the inflammatory cells and myocardium within the peri-sinoatrial nodal area in response to the infarction. These results provide evidence for the local expression of cytokines in the post-ischemic peri-sinoatrial nodal area, suggesting that the upregulation of the cytokines might be associated with the atrial arrhythmia observed after acute myocardial infarction.

Animals↗

Effects of window and threshold levels on the accuracy of three-dimensional rendering techniques in coronary artery electron-beam CT angiography.

RATIONALE AND OBJECTIVES: The authors performed this study to evaluate the effect of window level and gray-scale threshold on the demonstration of coronary artery lumina at three-dimensional electron-beam computed tomographic (CT) angiography. MATERIALS AND METHODS: Forty-four coronary artery branches in postmortem pigs were evaluated with electron-beam CT angiography, and the findings were compared with those from conventional angiography. Images from electron-beam CT angiography were reconstructed with maximal intensity projection (MIP), multiplanar reformation (MPR), and shaded-surface display (SSD). Four categories of window level and gray-scale threshold were evaluated. RESULTS: Three-dimensional electron-beam CT angiography accurately depicted the luminal diameters of the coronary arteries compared with conventional angiography (r = 0.83-0.90, P < .0001). The length of lumina visualized at electron-beam CT angiography was significantly shorter than that visualized with conventional angiography (P < .001). The use of MPR enabled visualization of longer segments of coronary arteries than did the use of MIP or SSD (P < .05). The higher the window level and gray-scale threshold used, the smaller the coronary luminal diameters measured (P < .05). The most accurate window level and gray-scale threshold (82.6 HU +/- 29.8 and 89.5 HU +/- 29.7, respectively) were found to correspond to the attenuation of the lumina (275.8 HU +/- 58.8). Results of simple linear regression showed a strong correlation between luminal attenuation and window level (r = 0.89, P < .0001) or gray-scale threshold (r = 0.95, P < .0001). CONCLUSION: Electron-beam CT angiography shows promise in the visualization of coronary artery lumina. For accurate display of lumina, a proper window level and gray-scale threshold for three-dimensional rendering techniques should be determined and used on the basis of the attenuation of the target vessel.

Animals↗

Electron beam tomography with three-dimensional reconstruction in the diagnosis of aortic diseases.

BACKGROUND: This study was performed to evaluate the protocols of electron beam tomographic angiography and three-dimensional reconstruction for assessing the diagnostic value of aortic diseases. METHODS EXPERIMENTAL DESIGN: Retrospective and comparative study. SETTINGS: University hospital. PATIENTS: Between 1996 and 1998, 189 cases who underwent electron beam tomographic angiography and diagnosed with aortic diseases were analyzed retrospectively. The results were compared with surgical and pathological findings in 68 cases. Electron beam tomographic angiography was used single-slice-scanning with ECG-triggering for screening of the thoracic aorta, continuous-volume-scanning, permitted by continuous X-ray exposure with table incremention, was performed for the abdominal aorta scanning without ECG-triggering. Three-dimensional reconstructions were performed with shaded-surface display, multiplanar reformatting and/or maximum intensity projection methods. RESULTS: Electron beam tomography angiography with ECG-triggered sections of single-slice-scanning improved the image quality of the ascending aorta without motion artifacts. Continuous-volume-scanning was suitable for screening of the abdominal aorta because of minimizing exposure time (10-14 sec) and saving contrast media (total contrast material of 45.5+/-6.6 ml was needed). One hundred eighty-nine cases were diagnosed with aortic dissection (97 cases), aortic aneurysm (26 cases), pseudoaneurysm (8 cases), Marfan's syndrome (39 cases), Takayasu's arteritis (5 cases) and congenital aortic malformations (14 cases). Electron beam tomography results were compared with the findings of surgery (as gold standard) in 68 cases, the diagnostic accuracy was 97% (2 cases with aortic aneurysm were erroneously diagnosed with pseudoaneurysm). CONCLUSIONS: Electrocardiographically triggered, contrast-enhanced electron beam tomography is feasible for the diagnosis of all kinds of aortic diseases, with excellent three-dimensional images competitive in quality with conventional selective aortic angiography or digital subtraction angiography.

Adolescent↗

Role of transesophageal echocardiography in pre- and post-percutaneous balloon mitral valvuloplasty.

Transesophageal echocardiogram (TEE) was performed in 33 consecutive patients with both rheumatic mitral stenosis and chronic atrial fibrillation to evaluate the usefulness of this technique for the detection of left atrial thrombi, mitral regurgitation before percutaneous balloon mitral valvuloplasty and iatrogenic atrial septal defect after the procedure. TEE correctly identified thrombi in 10 (30%) patients and significant mitral regurgitation in 5 patients who underwent surgical intervention. The remaining 18 patients underwent percutaneous balloon mitral valvuloplasty without evidence of systemic embolic event and obtained adequate outcome. Transesophageal color doppler echocardiography demonstrated left-to-right shunting flow through atrial septum in 5 of 7(71%) patients 3 days after the procedure and repeated TEE in 2 of these 5 patients showed no shunting after 6 months. In conclusion, TEE plays a definite role in the selection of patients for balloon mitral valvuloplasty and assessment of iatrogenic atrial septal defect.

Adult↗

[Primary pericardial mesothelioma: a report of four cases].

Pericardial mesothelioma is an uncommon variety of primary malignant cardio-pericardial tumors. Four cases with pericardial mesothelioma proved by surgery and pathology are reported in this paper. The pathologic and clinical characteristics, and the imaging diagnosis of this entity are briefly discussed.

Adolescent↗

Coronary artery stenoses: a phantom study using contrast enhanced three-dimensional electron beam tomography.

This paper evaluated the accuracy of electron beam tomographic angiography (EBA) with conventional coronary arteriography (CCA) using four graded artificial stenoses in a postmortem swine coronary phantom model. The sensitivity, specificity, and accuracy of EBA for diagnosing significant stenosis (> or =50% stenosis) were 94.3%, 96.7%, and 95.8%, respectively. The diagnostic accuracy of EBA had no significant difference with CCA (chi(2)=0.0162; P>.05). EBA three-dimensional (3D) procedures had high interobserver reproducibility (k=.92-.95, P>.05). Maximum intensity projection (MIP) was the most sensitive and curved planar reformation (CPR) was the most accurate 3D procedure for quantitatively identifying coronary stenosis. EBA yields promising results concerning the visualization of coronary artery stenosis with high accuracy for stenoses >50%.

Animals↗