PubMed Health⌕ Search

Biomedical subjects

R P Javier

Publications and source records attributed to R P Javier.

At least 19 recordsLinked to original sources

New principles for optimum left ventriculography.

Left ventriculography has become the single most important procedure in the evaluation of cardiac function. This study reevaluated the refinements of catheter and power injector technology to assess recommendations of past years and establish new principles for optimum ventriculography. Ventriculograms from 102 patients undergoing left heart catheterization and coronary arteriography for coronary, valvular, and myocardial heart disease served as the test sample. Three styles of #7F high-flow 110-cm pigtail catheters were utilized. One had 12 sideholes while the other two had six sideholes positioned nearer the base of the curl. Analysis of ventriculographic quality of each angiogram was performed by three of the authors independently and subsequently together. Five variables were analyzed for their effect on the diagnostic quality of the angiogram: 6-hole catheters, 12-hole catheters, volume of contrast, flow rate, and location of injection. Once these analyses were complete, the effect of combinations of these variables was tested to determine their effect on angiographic quality. The first combination included contrast volume and flow rate. The second combination compared contrast volume and flow rate when utilized with 6- or 12-hole catheters. The third combination tested the 6- and 12-hole catheters in the apex or inflow locations. A multivariate contingency analysis was used to define relationships between the variables and the quality of the angiogram obtained. As independent variables, catheter style, volume of contrast, flow rate, and location of injection did not influence angiographic quality. However, the apex as a location of injection was the single most consistently important determinant of ventricular angiographic quality.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Catheterization↗

Pseudo complications of cardiac catheterization: update.

This prospective study was performed to determine whether complications that occur immediately before or after the time of scheduled catheterization are as much disease-related as procedure-related. During 24 months all complications associated with 1,606 diagnostic cardiac catheterizations were recorded if they occurred from 24 hours before the time the procedure was scheduled to 72 hours later, longer if complications were clearly procedure-related. Pseudo complications are spontaneous medical or surgical incidents that occur during the 24-hour period before catheterization is scheduled to be performed. Procedure-related complications are incidents that occur during or after the catheterization procedure. There were 13 (0.81%) procedure-related complications but not deaths. There were 13 (0.81%) pseudo complications including 4 (0.24%) deaths. All complications were similar in nature except for 3 instances of vascular injury, which were procedure-related. Pseudo complications occur as commonly as procedure-related complications and at times are more severe. Complications occurring before catheterization are related to the underlying disease process and not medical intervention. It is likely that similar disease-caused incidents occur after a catheterization and are not necessarily procedure-related.

Adolescent↗

Pacer-induced tachycardia associated with an atrial synchronous ventricular inhibited (ASVIP) pulse generator.

A 68-year-old white male underwent permanent pacemaker implantation with an atrial synchronous ventricular inhibited pulse generator (Medtronic model 2409) because of syncope and abnormal H-V interval of 70 ms. Paroxysmal bouts of pacemaker associated tachycardia were subsequently recorded on several occasions, initiated and terminated by spontaneous ventricular premature beats. The mechanism for the occurrence of the tachyarrhythmia is discussed in detail and the functional characteristics of the pulse generator are described. Replacement of the unit with a different pacer device prevented further occurrence of the arrhythmia.

Aged↗

Inotropic action of tolbutamide on human myocardium.

The inotropic action of tolbutamide previously demonstrated in vitro was evaluated in 15 nondiabetic subjects during diagnostic cardiac catheterization. Following bolus injection of 250 mg of tolbutamide intravenously, a rise of serum insulin and a slight fall of serum potassium were observed. Inotropic response was determined from significant fall in PEP/LVET ratio, significant fall of left ventricular end-diastolic pressure, shift to an augmented function curve in work-pressure relationships, and prominent rise of dP/dt values at comparable heart rates. The inotropic effect was greatest at 5-15 min with return to near control values at 30 min. An unusually marked inotropic response was observed in one subject. While the measurable net hemodynamic effect of tolbutamide in the human heart is small, its effect on ischemic and normal areas within the heart of a diabetic patient with atherosclerosis may be different. Thus, its ultimate effect on the diseased heart may be significant.

Blood Glucose↗

Coronary arteriography: prevention of thromboembolic complications using a pressure-drip flushing technique.

All selective coronary arteriographic examinations (1,833) performed in the authors' laboratory during a five-year period (1/1/70 to 12/31/74) were analyzed for mortality and total morbidity according to method used. During the first two years, the control period, the classic brachial artery cutdown (Sones) and percutaneous femoral artery puncture (Judkins) techniques were utilized. Mortality rate for the total 589 patients was 1.01%. This included a mortality of 0.26% (1/386) for the brachial arteriotomy method, and 2.5% (5/203) for the percutaneous femoral puncture approach. After introduction of the pressure-drip flushing technique, the subsequent three-year mortality rate for a total of 1,244 patients was 0.16%. This included an incidence of 0.17% (1/585) for brachial arteriotomy and 0.15% (1/659) for modified percutaneous puncture techniques. The morbidity incidence during the initial two-year period was 3.0% (18/589). This included an incidence of 2.0% for brachial arteriotomy and 5.0% for percutaneous puncture techniques. After institution of the new pressure-drip flushing technique the total incidence fell to 1.2% equally divided between arteriotomy and percutaneous techniques. Modification of the classic percutaneous femoral artery puncture techniques has resulted in major reduction of mortality and morbidity complications which are chiefly thromboembolic in nature. It has not significantly influenced local thrombotic complications of arteriotomy.

Angiocardiography↗

Calcific aortic insufficiency--a review of 26 patients.

Twenty-six patients, 8.3 per cent of all patients with aortic valve disease, and 10.7 per cent of all patients with any degree of aortic insufficiency detected in our catheterization laboratory, had pure calcific aortic insufficiency (no associated stenosis). Nineteen (73 per cent) males and seven (27 per cent) females ranged in age from 25 to 75 years of age (mean 51). Twenty-three per cent were younger than 40. Sixteen (62 per cent) had rheumatic heart disease, one had luetic aortic valve disease, one had congenital bicuspid valve, and eight (31 per cent) had aortic insufficiency of undetermined etiology. Twenty-three patients (89 per cent) had an aortic systolic ejection murmur, and seven (28 per cent) had an aortic ejection click. Aortic valve calcification was detected by plain chest films in only four patients (16 per cent), and by routine image intensification fluoroscopy (before catheterization) in fifteen patients (68 per cent). The reamining 32 per cent had the calcification of the aortic valve detected during catheterization. Aortic valve calcification was severe in nine patients (35 per cent), moderate in eleven patients (42 per cent), and minimal in six patients (22 per cent). Aortic insufficiency was severe in twenty patients (77 per cent), moderate in five patients (19 per cent), and minimal in one patient (4 per cent). Nineteen patients (77 per cent) had reduced left ventricular contractility. Sixteen patients (67 per cent) had low cardiac index. Eighteen patients had obstructive coronary artery disease. Aortic stenosis was misdiagnosed as the predominant lesion in fourteen patients (54 per cent)--prior to catheterization. This series demonstrates that all patients with calcified aortic valve disease and with ejection murmurs do not necessarily have aortic stenosis. Pure calcific aortic insufficiency is a distinct entity, more common than previously suspected.

Adult↗