PubMed Health⌕ Search

Biomedical subjects

R P Reddy

Publications and source records attributed to R P Reddy.

12 recordsLinked to original sources

Study of the safety, immunogenicity and seroconversion of a hepatitis-B vaccine in malnourished children of India.

Sixty rural children who were seronegative for HBV markers received three doses of 10 microgram of a new Hepatitis-B vaccine, Revac-B (1 ml of vaccine contains 20 microgram recombinant surface antigen) that was formulated from hepatitis-B surface antigen expressed in a recombinant strain of Saccharomyces cerevisiae. Vaccines were administered on a 0, 30 and 60-day schedule. Levels of anti-HBs titres were determined on the 30th, 60th and 90th days following the initial injection. None of the participants in the trial had serious adverse reactions and the frequencies of minor side effects were minimal. No clinically important adverse effects which could be considered as directly related to the vaccination were recorded. The volunteers showed a very good immune response and were seroprotected on the 30th day after the first dose of vaccination. The present study revealed that the new vaccine, Revac-B is highly immunogenic and is well tolerated.

Child↗

Matrix metalloproteinase activities in avian tibial dyschondroplasia.

Tibial dyschondroplasia (TD) in poultry is a disorder of growth plate cartilage that fails to resorb and consequently prevents bone formation. Matrix metalloproteinases (MMP) contribute to the process of resorption through the degradation of extracellular matrices and facilitating vascularization, growth plate remodeling, and maturation. In order to understand the cause of the failure of cartilage degradation in TD, the gelatinase and collagenase activities, and the levels of collagen and glycosaminoglycans of conditioned media derived from cartilage-explant cultures of normal and TD growth plates were measured. Substrate zymography exhibited two prominent gelatinolytic and collagenolytic bands corresponding to MW 63, 59, and a broad but fuzzy band of activity between 100 and 200 kDa. On treatment with 4-aminophenylmercuric acetate, a compound that converts proenzyme forms of MMP, the 63 kDa MW gelatinolytic band migrated as a approximately 60 kDa band and contributed to the broadening of the 59 kDa band. The TD-growth plate-conditioned media had significantly lower collagenolytic-gelatinolytic activities. The sulfated glycosaminoglycans, but not the collagen contents of the conditioned media from TD-explant cultures, were also reduced significantly. It is likely that the decreased matrix metalloproteinase activities of growth plate chondrocyte may contribute to a reduced turnover of extracellular matrices (ECM), leading to the retention of cartilage and its lack of vascularity in TD-affected growth plates.

Animals↗

Comparison of 2-channel and 4-channel pneumograms.

To determine whether the addition of air flow and O2 saturation (SaO2) channels improves sensitivity of the pneumogram in identifying cardiorespiratory pattern abnormalities, 2- and 4-channel pneumograms (PG-2 and PG-4) were simultaneously recorded in 91 consecutive infants. Forty-one infants (45%) had cardiorespiratory symptoms, and 50 were asymptomatic. Pneumograms were considered abnormal for any of the following: apnea greater than or equal to 20 seconds, heart rate less than 80 bpm for greater than 5 seconds in preterm and less than 60 bpm in full-term infants (bradycardia), shorter apnea with bradycardia or desaturation, periodic breathing greater than 7% of total sleep time in preterm and greater than 4% in full-term infants, or SaO2 less than 85% for greater than 5 seconds. Both recordings were normal in 72% of infants and abnormal in 24%. In only 4% were the PG-4 abnormal when the PG-2 were normal, in all instances due to minimum SaO2 levels of 77-84% for 5-19 seconds associated with central apnea of intermediate duration (three infants) or with mixed apnea. The difference in frequency of abnormal results between the PG-2 and PG-4 recordings was not statistically significant (X2). In conclusion, although PG-4 do increase the scope of physiological information obtained in infants with cardiorespiratory events, this short-term study does not establish whether this increase results in any long-term benefits. Further, at least in this number and these types of at-risk infants, PG-4 do not improve the sensitivity of cardiorespiratory recordings for detecting abnormalities.

Bradycardia↗

Extracorporeal membrane oxygenation in the neonate.

ECMO is a modified heart-lung bypass system for treatment of moribund neonates. The techniques are described. Our experience with 19 patients reveals a survival rate of 79 percent. In the future, with advances in technology, ECMO may become less invisible and extended to a larger population of newborns.

Extracorporeal Membrane Oxygenation↗

Prospective observational study of primary angioplasty of the infarct-related artery for acute myocardial infarction.

Primary angioplasty has been shown to reduce rates of in-hospital mortality, recurrent ischaemia and infarction. However, the role of primary stenting and abciximab is presently undergoing evaluation. This study attempted to examine the feasibility, safety and outcomes of primary angioplasty in the treatment of acute myocardial infarction. Data in 100 patients who underwent primary angioplasty for evolving acute myocardial infarction was prospectively analysed to assess the safety and efficacy of various modalities. Twenty patients were in Killip class III and above. Multivessel (2 or more vessels) disease was noted in more than 52 cases. Procedural success was 99 percent; 86 patients received primary stenting, majority of them had Kalam-Raju stent implantation. Adjunct treatment included abciximab infusion in 22 and intra-aortic balloon pump support in 12. Overall mortality rate was six percent with a mortality of 2.2 percent in non-cardiogenic shock patients. Recurrent ischaemic events were noted in five, three of them had successful reperfusion with repeat angioplasty. None of the patients had emergency coronary artery bypass surgery. It is concluded that primary angioplasty is safe and effective with high procedural success. Recurrent ischaemic events are low, possibly due to routine use of stenting and selective use of abciximab.

Abciximab↗

The natural history of cervical spondylotic myelopathy.

This is a retrospective study of twenty-two patients with cervical spondylotic myelopathy who were admitted to the hospital for surgical treatment of their neurological condition. The purpose of the study was to evaluate the presenting symptoms, factors affecting the diagnosis and the course of the disease prior to surgical intervention. The earliest consistent symptom in all of our patients was a gait abnormality. The course of the disease was one of progressive deterioration. Spontaneous regression did not occur in any of the cases. The vagueness of the initial complaints led to considerable delay in the diagnosis (average of 6.3 years). Magnetic Resonance Imaging (MRI) was the most useful test in confirming the diagnosis.

Adult↗

Clinical evaluation of new balloon mountable coil stent: in-hospital and follow-up results.

The purpose of this study was to determine the feasibility, safety and efficacy of elective deployment of a new coil-stent (KR stent) in patients with coronary artery disease. KR stent deployment was attempted in 100 patients (135 lesions) enrolled prospectively at a single centre from December 1996 to March 1997. Ten, 15, 18, 24, and 32 mm long KR stents were manually crimped onto balloons and deployed in native coronary artery lesions. Majority of the patients had recent acute coronary syndromes (unstable angina 30% and post-myocardial infarction angina 56%). Diabetes was present in 34 percent of the patients. Fifty-six percent had single-vessel and 44 percent multi-vessel disease. In 38 percent, the lesions were located in proximal segments and 40 percent of lesions were long. KR stents were successfully deployed in 98 percent of patients. Mean minimal luminal diameter increased by 2.89 +/- 0.63 mm (from 0.57 +/- 0.38 mm before to 3.45 +/- 0.56 mm after the procedure). Mean percent diameter stenosis decreased from 83.33 +/- 10.84 percent before to 3.38 +/- 5.74 percent after the stent deployment. Mean reference vessel diameter was 3.45 +/- 0.56 mm. There were occasional technical complications including balloon rupture (1), stent migration (2) and distal embolisation of atheromatous material (1). One patient developed subacute stent thrombosis. There were no other major in-hospital cardiovascular events. At the end of six-month follow-up, there were no myocardial infarction or death. Six patients presented with recurrence of symptoms within six-months of the procedure, four of whom underwent target vessel revascularisation procedure. In conclusion, the in-hospital and six-month follow-up clinical results were highly encouraging with KR stent. Successful deployment rates were high despite unfavourable clinical and angiographic background. Low clinical events on follow-up will make it suitable for elective stenting.

Adult↗