A study to validate the method based on DIMOND quality criteria for cardiac angiographic images.

A method based on image quality criteria (QC) for cine-angiography was developed to measure the quality of cine-angiograms (CA). A series of 30 CA for left ventriculography (LV) and left and right coronary angiography (LCA, RCA) have been scored and 172 readings were obtained. Standard deviation of quality scores indicated the reproducibility of the method. Each part of CA was examined separately, giving scores for LV, LCA and RCA and a total score (TS), with clinical (C) and technical (T) criteria defined and examined separately. In 83% of the studies TS was >0.8 and with standard deviation from 0.02 to 0.21. In general, LV had a lower score and greater disagreement compared with RCA and LCA. Disagreement was greater in T, compared with C. In conclusion, these results indicate that QC, translated into a scoring system, yields reproducible data on the quality of cardiac images.

Cineangiography↗

Correlation of patient and staff doses in interventional cardiology.

The purpose of this study was to measure staff radiation doses in representative institutions of five European countries performing coronary angiographies (CA) and percutaneous transluminal coronary angioplasties (PTCA), as well as to investigate any correlation with patient doses. Patient doses were recorded in terms of dose-area product (DAP). Staff doses were measured by thermoluminescence dosemeters placed on the operator's left shoulder and left foot. Radiation protection measures were also recorded. Third quartile shoulder and foot doses were 90 and 66 microSv in CA, and 157 and 173 microSv in PTCA, respectively. Shoulder dose was poorly correlated with DAP in CA (R2 = 0.29) and only moderately correlated in PTCA (R2 = 0.69). DAP and foot dose correlation was poor both in CA (R2 = 0.16) and in PTCA (R2 = 0.02). Protective measures taken by staff varied between countries, which may explain the poor correlation of patient and staff radiation doses.

Angioplasty, Balloon, Coronary↗

The application of image quality measurements for digital angiography.

The image quality (IQ) evaluation of a charge-coupled device (CCD)-based digital angiography system was assessed with respect to modulation transfer function and noise power spectrum. These values were used to calculate the system's frequency-dependent detective quantum efficiency (DQE). The X-ray image detector was an image intensifier (II) lens coupled to a CCD camera. Two measurement setups were used. Setup A is standard IQ assessment, while Setup B more closely represented clinical conditions (polymethyl methacrylate (PMMA) of varying thickness placed between the X-ray tube and II, with test object positioned between PMMA slices 30 cm from the II). Exposure parameters varied according to automatic brightness control settings. Setup B included X-ray radiation scattered by the patient-PMMA. A clinical DQE, describing the transmission of the input signal-to-noise ratio associated with both primary and secondary X-ray spectra, was defined.

Angiography↗

Reference levels in PTCA as a function of procedure complexity.

The multicentre assessment of a procedure complexity index (CI) for the introduction of reference levels (RLs) in percutaneous transluminal coronary angioplasties (PTCA) is presented here. PTCAs were investigated based on methodology proposed by Bernardi et al. Multiple linear stepwise regression analysis, including clinical, anatomical and technical factors, was performed to obtain fluoroscopy time predictors. Based on these regression coefficients, a scoring system was defined and CI obtained. CI was used to classify dose values into three groups: low, medium and high complexity procedures, since there was good correlation (r = 0.41; P < 0.001) between dose-area product (DAP) and CI. CI groups were determined by an ANOVA test, and the resulting DAP and fluoroscopy time third quartiles suggested as preliminary RLs in PTCA, as a function of procedure complexity. PTCA preliminary RLs for DAP are 54, 76 and 127 Gy cm2, and 12, 20 and 27 min for fluoroscopy time, for the three CI groups.

Analysis of Variance↗

On the use of DICOM cine header information for optimisation: results from the 2002 European DIMOND cardiology survey.

The paper explores the level of information contained within the DICOM header in images from various cardiology systems. Data were obtained in the European DIMOND survey on image quality (Italy, Ireland, Belgium, Greece and Spain). Images from five standard diagnostic cardiology procedures carried out in six European hospitals have been analysed. DICOM header information was extracted to a database in order to analyse how it could help in the optimisation of the procedures. The level of data contained in the headers differs widely between cardiology systems. None of the X-ray systems in the 2002 survey archives the dosimetric data in the DICOM header. The mean number of runs per procedure ranges between 7.5 and 15.4 and the mean number of frames per procedure between 575 and 1417. Differences in kVp, mA, pulse time, distances and C-arm angulations are substantial and suggest that there exists a wide range for optimisation.

Cardiology↗

Are new technologies always reducing patient doses in cardiac procedures?

Dynamic digital flat-panel (FD) imaging technology is characterised by a higher sensitivity and image quality compared to image intensifier (II) technology. In this study, an angiography system based on II and one based on FD were compared with respect to system performance and impact of patient dose in interventional cardiology. When entrance surface air kerma rates are measured, the FD system requires a reduced dose rate, of up to 40%. For coronary angiography (CA), fluoroscopy time (FT) and dose-area product (DAP) were 4.3 +/- 5.0 min and 31.2 +/- 30.2 Gy cm2 on the II system and 4.4 +/- 3.8 min and 33.4 +/- 19.2 Gy cm2 with the FD system. For percutaneous transluminal coronary angiography, FT and DAP were 11.4 +/- 10.7 min and 52.1 +/- 45.0 Gy cm2 on II and 10.7 +/- 8.7 min and 66.9 +/- 54.4 Gy cm2 on DF. Data comparison suggests that reduced entrance dose rates do not automatically imply a reduction of patient dose in clinical practice.

Cardiology↗

Image quality criteria in cardiology.

Image quality evaluation plays a key role in the process of optimisation in radiological procedures. Image quality criteria for cardiac cine-angiography were recently agreed as part of a European Research Project, and a scoring system based on these criteria has been developed to allow an 'objective' measurement of the quality of cardiac angiograms. Two studies aimed at the evaluation of the methodology have been completed, demonstrating that the method can be applied to cardiac images and translated into a scoring system that yields reproducible data. Based on the results of these studies, quality criteria have been further reviewed by DIMOND III panel and the updated version is presented in this paper.

Cardiology↗

Patient dosimetry approaches in interventional cardiology and literature dose data review.

Interventional radiology contributes a significant proportion of the collective dose of the population from medical exposures. Interventional radiology procedures are usually fluoroscopy-guided diagnostic and therapeutic interventions. When complex procedures are performed or procedures are repeated for the same patient, high-radiation dose levels can occur because procedures often require long fluoroscopy times and require high-quality images. For all of these reasons, dosimetric evaluations in interventional radiology are widely increasing. Patient dosimetry methods currently used in interventional radiology may be divided into three categories according to dosimetry purpose: (I) dosimetry for stochastic risk evaluation, (II) dosimetry for quality assurance and (III) dosimetry to prevent the deterministic effects of radiation. A short description of dosimetric methods used in interventional cardiology practice and relevant published dosimetric data are reported.

Angioplasty, Balloon, Coronary↗

Radiation dose levels during interventional cardiology procedures in a tertiary care hospital.

The aim of our investigation was to prospectively measure the patient radiation exposure from different cardiological procedures performed in the Catheterisation laboratory of the University Hospital Gasthuisberg in Leuven. The following local reference values were proposed: 40, 47 and 80 Gycm2 for coronary angiography (CA) or angioplasty (PTCA and stent implantation for elective patients), radio frequency ablation with angiographic images and CA plus ad hoc PTCA, respectively.

Angioplasty, Balloon, Coronary↗

Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology.

With the increase in number and complexity of interventional cardiology (IC) procedures, it is important to monitor skin dose in order to decrease skin injuries. This study investigated radiation doses for patients undergoing IC procedures, compare results with the literature and define a local dose-area product trigger level for operators to identify situations likely to exceed the threshold for transient skin erythema of 2 Gy. Dosimetric data were collected for 77 haemodynamic and 90 electrophysiological procedures. Mean maximum local skin doses (MSDs) were 0.28 Gy for coronary angiography, 1.03 Gy for percutaneous transluminal coronary angioplasty (PTCA), 0.03 Gy for pacemaker insertion, 0.17 Gy for radiofrequency ablation for nodal tachycardia, 0.10 Gy for WPW and 0.22 Gy for atrial flutter. Since MSD values for the other procedures were well below the deterministic effect limit, a trigger level of 140 Gy cm2 was derived for PTCA procedures alone.

Angioplasty, Balloon, Coronary↗

Retrospective evaluation of occurrence of skin injuries in interventional cardiac procedures.

Interventional cardiology procedures can involve high doses to patients and, in particular, to patients' skin, the tissue at greatest risk of deterministic injuries. The evaluation of skin dose from interventional procedures is recommended, but difficult because of the amount of different X-ray fields and projections used in a procedure. For this reason, a retrospective follow-up study has been developed to identify skin injuries in patients submitted to one or more cardiac interventions in the Udine hospital between 1998 and 2002. Seventy-eight patients with a cumulative dose-area product >300 Gy cm2 were selected from 3332 patients, who underwent 5039 procedures. In this group the maximum skin dose was 6.7 Gy. The clinical follow-up, performed using the LENT-SOMA methodology, has not detected skin injuries and this result allows a frequency to be estimated for skin injuries in patients undergoing repeated cardiac procedures of <3 x 10(-4) in our centre.

Aged↗

Dose to cardiologists in haemodynamic and electrophysiology cardiac interventional procedures.

Interventional cardiac procedures can be complex and involve extensive use of low dose rate fluoroscopy and high dose rate in image acquisition mode; hence, staff may receive significant radiation exposure. Radiation exposure to operators was assessed in 173 procedures. Fluoroscopy time, number of acquired images and dose-area product were recorded and occupational dose assessed with thermoluminescence dosemeters. The effective dose to the operator was compared with relevant literature data: values found were generally lower than those reported for other interventional cardiology laboratories. This is probably because of the strict radiation protection policy in our centre. Higher effective doses were found for defibrillator implantation and percutaneous transluminal coronary angiography procedures; for other cardiac procedures, effective dose was lower. Yearly extrapolated occupational doses to cardiologists are lower than the regulatory dose limit and in the lower band of doses reported in the literature.

Algorithms↗

Non-alcoholic fatty liver disease is associated with carotid artery wall thickness in diet-controlled type 2 diabetic patients.

Non-alcoholic fatty liver disease (NAFLD) is closely associated with several metabolic syndrome (MetS) features. We assessed whether NAFLD is significantly associated with carotid artery intima-media thickness (IMT), as a marker of subclinical atherosclerosis, and whether such association is independent of classical cardiovascular risk factors and MetS features. We studied 100 diet-controlled Type 2 diabetic patients with ultrasonographically diagnosed NAFLD and 100 diabetic patients without NAFLD who were comparable for age and sex. Main outcome measures were carotid IMT (by ultrasonography), classical risk factors, insulin resistance [as estimated by homeostasis model assessment (HOMA)-IR] and MetS (as defined by the Adult Treatment Panel III criteria). NAFLD patients had a markedly greater carotid IMT (1.24 +/- 0.13 vs 0.95 +/- 0.11 mm; p < 0.001) than those without the condition. The MetS and all its clinical traits were more highly prevalent in those with NAFLD (p < 0.001). Adjustment for age, sex, smoking history, diabetes duration, glycosylated hemoglobin, LDL cholesterol, liver enzymes and microalbuminuria did not really affect the significant differences in carotid IMT that were observed between the groups. Further adjustment for the MetS also had little impact, but additional adjustment for HOMA-IR score consistently attenuated any statistical significance (p = 0.28). In multivariate regression analysis, HOMA-IR score along with age and MetS (principally raised blood pressure values) were independently related to carotid IMT, whereas NAFLD was not. In conclusion, these results suggest that among diet-controlled Type 2 diabetic individuals the significant increase of carotid IMT in the presence of NAFLD is largely explained by HOMA-estimated insulin resistance.

Abdominal Fat↗

Increased prevalence of cardiovascular disease in Type 2 diabetic patients with non-alcoholic fatty liver disease.

AIMS: To estimate the prevalence of cardiovascular disease (CVD) in Type 2 diabetic patients with and without non-alcoholic fatty liver disease (NAFLD), and to assess whether NAFLD is independently related to prevalent CVD. METHODS: We studied 400 Type 2 diabetic patients with NAFLD and 400 diabetic patients without NAFLD who were matched for age and sex. Main outcome measures were prevalent CVD (as ascertained by medical history, physical examination, electrocardiogram and echo-Doppler scanning of carotid and lower limb arteries), NAFLD (by ultrasonography) and presence of the metabolic syndrome (MetS) as defined by the World Health Organization or Adult Treatment Panel III criteria. RESULTS: The prevalences of coronary (23.0 vs. 15.5%), cerebrovascular (17.2 vs. 10.2%) and peripheral (12.8 vs. 7.0%) vascular disease were significantly increased in those with NAFLD as compared with those without NAFLD (P < 0.001), with no differences between sexes. The MetS (by any criteria) and all its individual components were more frequent in NAFLD patients (P < 0.001). In logistic regression analysis, male sex, age, smoking history and MetS were independently related to prevalent CVD, whereas NAFLD was not. CONCLUSIONS: The prevalence of CVD is increased in patients with Type 2 diabetes and NAFLD in association with an increased prevalence of MetS as compared with diabetic patients without NAFLD. Follow-up studies are necessary to determine whether this higher prevalence of CVD among diabetic patients with NAFLD affects long-term mortality.

Aged↗

Preliminary reference levels in interventional cardiology.

This article describes the European DIMOND approach to defining reference levels (RLs) for radiation doses delivered to patients during two types of invasive cardiology procedures, namely coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA). Representative centres of six European countries recorded patients' doses in terms of dose-area product (DAP), fluoroscopy time and number of radiographic exposures, using X-ray equipment that has been subject to constancy testing. In addition, a DAP trigger level for cardiac procedures which should alert the operator to possible skin injury, was set to 300 Gyxcm2. The estimation of maximum skin dose was recommended in the event that a DAP trigger level was likely to be exceeded. The proposed RLs for CA and PTCA were for DAP 45 Gyxcm2 and 75 Gyxcm2, for fluoroscopy time 7.5 min and 17 min and for number of frames 1250 and 1300, respectively. The proposed RLs should be considered as a first approach to help in the optimisation of these procedures. More studies are required to establish certain "tolerances" from the proposed levels taking into account the complexity of the procedure and the patient's size.

Angioplasty, Balloon, Coronary↗

Spinal dural arteriovenous fistulas: the use of intraoperative microvascular Doppler monitoring.

Spinal dural arteriovenous fistulas are characterized by an abnormal communication between the dural branch of the radiculomedullary artery and an intradural medullary vein. Although the optimal treatment strategy is still debated, a complete interruption of the flow in the fistulas should be obtained. The authors report four cases operated on with intraoperative microvascular Doppler monitoring assistance. In all cases, microDoppler confirmed the location of the fistula and revealed an arterial spectrum on the redundant dorsal medullary veins. After the clipping of the feeder of the arteriovenous shunt, the intraoperative monitoring documented a complete disappearance of the arterial spectrum and the reappearance of the venous pattern. The ultrasonographic changes suggested the complete interruption of the fistulas. Postoperative angiography showed no residual abnormality in all patients. Doppler monitoring during surgery confirms satisfactory interruption of the arterial feeder and may prove useful where initial identification of the feeding vessel is difficult.

Aged↗

Patient dose values in a dedicated Greek cardiac centre.

The purpose of this study was to collect information on the practice and patient doses in a major Greek cardiac centre, investigate differences between senior cardiologists of various levels of experience and compare results with the literature, in order to optimize angiographic and interventional cardiology procedures. Radiation doses from 292 patients have been studied, 195 of which had undergone coronary angiography and 97 percutaneous transluminal coronary angioplasty. All procedures were undertaken on a Siemens Angioscop X-ray equipment. The system performed under automatic exposure control using pulsed fluoroscopy of 12.5 pulses s(-1) and cine frame rate of 25 frames s(-1). Dose-area product values, fluoroscopy times, total number of cine frames as well as operator's name were collected for each patient. Only senior cardiologists have participated in the study. Median values for dose-area product were 39.1 Gy cm(2) for coronary angiography and 58.3 Gy cm(2) for percutaneous transluminal coronary angioplasty. Median fluoroscopy time was 5.0 min and 9.7 min and median number of frames was 1588 and 1823 for coronary angiography and percutaneous transluminal coronary angioplasty, respectively. Comparison showed that patient dose-area product values were lower than other studies and fluoroscopy time values were comparable. However, the total number of frames used was much higher than other published results. Differences between cardiologists with increased experience have been found. Analysis of the patient dose values obtained initiated a program of radiation protection optimization. The need for continuous training in radiation protection for interventionalists has been verified.

Adult↗