Development of a fluorescent light technique for evaluating microdamage in bone subjected to fatigue loading.

A new method using fluorescent light microscopy has been developed to visualize and evaluate bone microdamage. We report the findings of two different experiments with a common aim of comparing the fluorescent light technique to the brightfield method for quantifying microdamage in bone. In Experiment 1, 36 canine femurs were tested in four-point cyclic bending until they had lost between 5 and 43% of their stiffness. The loaded portion of the bone was stained en bloc with basic fuchsin for the presence of damage. Standard point counting techniques were used to calculate fractional damaged area (Dm.Ar = Cr.Ar/B.Ar, mm2/mm2) under brightfield and fluorescent microscopy. In Experiment 2, bone microdamage adjacent to endosseous implants, subjected to fatigue loading (150,000 cycles, 2 Hz and 37 degrees C) ex vivo was examined. The bone around the implant was either allowed to heal (adapted specimen) for 12 weeks after placement in dog mid-femoral diaphyses prior to testing or was loaded immediately to simulate non-healed bone surrounding endosseous implants (non-adapted). Crack numerical density (Cr.Dn = Cr.N/B.Ar, #/mm2), crack surface density (Cr.S.Dn = Tt.Cr.Le/B.Ar, mm/mm2) and fractional damaged area were calculated separately by both techniques in the adapted and non-adapted specimens. In both Experiments 1 and 2, significantly more microdamage was detected by the fluorescent technique than by the brightfield method. Also, there was a trend towards higher intraobserver repeatability when using the fluorescent method. These results suggest that the brightfield technique underestimates microdamage accumulation and that the fluorescent technique better represents the actual amounts of microdamage present. The results demonstrate that the fluorescent method provides an accurate and precise approach for bone microdamage evaluation, and that it improves the prediction of stiffness loss from damage accumulation.

Animals↗

En bloc staining of bone under load does not improve dye diffusion into microcracks.

Microdamage accumulation in bone has been implicated in the pathogenesis of some bone fractures, and in implant loosening. Standard techniques for staining microcracks may not allow all cracks to be stained. We tested the hypothesis that crack closure in bone cortices after removal of a bending load may prevent diffusion of stain to sites of microcrack nucleation. Following cyclic loading, 26 canine femurs were divided into a group stained en bloc while applying a four point bending load, and another group stained without an applied load. No differences in number or length of microcracks were observed, indicating that crack closure does not prevent diffusion of stain to the crack location. Staining under load is unnecessary.

Animals↗

Does microdamage accumulation affect the mechanical properties of bone?

It has never been demonstrated that microcrack accumulation in bone leads to impaired mechanical properties. We hypothesized that microdamage accumulation is positively and linearly correlated with a reduction in bone's elastic modulus. We also tested the hypothesis that damage accumulates more rapidly in tensile cortices, but crack growth is greater in compressive cortices. Canine femurs (n = 26) were tested in four-point cyclic bending under load control until they had lost between 5 and 43% of their stiffness. Ten femurs were used as nonloaded controls. The loaded portion of the bone was stained en bloc with basic fuchsin to detect the presence of microdamage. The number of stained microcracks, their lengths and the area of damaged bone were measured under the microscope. Crack numerical density, surface density, mean crack length, and the percentage of damaged area were calculated. Significant microdamage accumulation was not detected until the bone had lost 15% of its elastic modulus. The relationship between crack density and stiffness loss was approximately quadratic, but the relationship between damaged area and stiffness loss was linear. There were significantly more microcracks in tensile cortices, but on average cracks were significantly longer in compressive cortices. We conclude that microcrack accumulation impairs the mechanical properties of bone by reducing its elastic modulus. We also conclude that damage accumulates more rapidly in tensile cortices, but crack growth is greater in compressive cortices.