PubMed Health⌕ Search

Biomedical subjects

R Pijpers

Publications and source records attributed to R Pijpers.

31 records · Page 2Linked to original sources

Reliability of intraoperative frozen section and imprint cytological investigation of sentinel lymph nodes in breast cancer.

AIMS: The sentinel lymph node procedure enables selective targeting of the first draining lymph node, where the initial metastases will form. A negative sentinel node (SN) predicts the absence of tumour metastases in the other regional lymph nodes with high accuracy. This means that in the case of a negative SN, regional lymph node dissection is no longer necessary. Besides saving costs, this will prevent many side-effects of lymph node dissection. The aim of this study was to evaluate the reliability of intraoperative cytological and frozen section investigation of the SN to detect metastases. This would allow the axillary lymph node dissection to be performed in the same session as the SN procedure and the excision of the primary tumour in case of a positive SN. METHODS AND RESULTS: Seventy-four SNs were detected by gamma probe detection of nanocolloid and visual localization of Patent Blue accumulations in 54 women with stage T1-2N0M0 invasive breast cancer. The identified SN were immediately investigated by frozen section and imprint cytological investigation. Diagnoses were confirmed on the paraffin material, and in case of negative frozen section and paraffin haematoxylin and eosin sections, skip sections and immunohistochemistry were performed. Thirty-one SNs (42%) contained metastases, of which 27 were detected by the frozen section procedure (sensitivity 87%). There were no false positives (specificity 100%). The sensitivity of the imprints was 62% with a specificity of 100%. When evaluating the data per patient, for the frozen section procedure the sensitivity was 91% and the specificity 100%, and for the imprints, the sensitivity was 63% and the specificity 100%. There were no SNs in which the imprints showed metastases and the frozen section did not. CONCLUSIONS: Intraoperative frozen section analysis is a reliable procedure by which a high percentage of sentinel lymph node metastases can be detected in breast cancer patients without false positive results. This allows the surgeon to perform an immediate axillary lymph node dissection in case of positive SNs. In up to 10% of cases, the final paraffin sections will reveal micrometastases that were not detected by the frozen section, and in these patients axillary lymph node dissection will have to be performed in a second session. The imprint method is significantly less sensitive than the frozen section but may be used as an alternative when frozen section is not possible.

Adult↗

[The sentinel node procedure: standard intervention for surgical treatment of breast cancer].

Axillary lymph node dissection may be avoided in the surgical treatment of breast cancer if the sentinel node appears to be free of metastatic tumour cells. The sentinel node concept has been validated in hundreds of patients, in whom this node has been localized successfully by dye-guided node mapping and (or) gamma-probe localization after injection of a radiopharmaceutical agent. The success rate of sentinel node localization depends on different factors, such as type, volume and injection site of the radiopharmacon, choice of the handheld gamma-probe, timing of the blue dye injection, and clinical stage of the disease. The combination of preoperative lymphoscintigraphy, intraoperative gamma-probe guidance and blue dye administration will increase the success rate of a sentinel node biopsy. Recent reports, from both Europe and the United States, appear to indicate that the sentinel node biopsy will soon be standard procedure in the surgical treatment of (T1-2) breast cancer. In the majority of breast cancer patients axillary lymph node dissection, a cause of much morbidity, may thus be avoided.

Axilla↗

Comparison between the effects of amlodipine and lisinopril on proteinuria in nondiabetic renal failure: a double-blind, randomized prospective study.

Double-blind, randomized controlled studies of longer than 1 week in duration comparing the antiproteinuric potential of long-acting dihydropyridine calcium channel blockers with that of angiotensin converting enzyme (ACE) inhibitors are lacking. Therefore, we performed such a study in patients with nondiabetic renal disease and proteinuria. After a 4-week wash-out period in which patients did not use any medication known to affect proteinuria, 21 patients were randomized in a double-blind fashion to receive either the calcium channel blocker amlodipine (Amlo, 5 to 10 mg) or the ACE-inhibitor lisinopril (Lis, 5 to 10 mg). Throughout the 16-week study period, blood pressure, creatinine clearances, and proteinuria were measured every 2 weeks. In addition, device-measured blood pressure and renal hemodynamic studies were performed at the start and end of the study. Systolic blood pressure fell in the Lis group from 163+/-7 (SEM) to 140+/-8 mm Hg (P < .01) and from 157+/-10 to 147+/-6 mm Hg in the Amlo group; diastolic blood pressure fell from 101+/-3 to 86+/-7 mm Hg in the Lis group and from 98+/-3 to 91+/-2 mm Hg in the Amlo group. Renal hemodynamics were not affected by amlodipine treatment, whereas a fall in glomerular filtration rate (GFR) was seen in lisinopril-treated patients (from 55+/-11 to 50+/-10 mL/min; P < .01). Amlodipine did not significantly affect proteinuria. Lisinopril induced a decline in the protein-creatinine ratio with a maximal effect reached after 12 to 16 weeks of therapy (from 0.39+/-0.17 to 0.26 +/-0.11 g/mmol; P < .009). In conclusion, we could not demonstrate an antiproteinuric effect of the long-acting dihydropyridine calcium channel blocker amlodipine, whereas therapy with the ACE-inhibitor lisinopril resulted in a decrease in proteinuria. Amlodipine did not affect renal hemodynamics, whereas lisinopril induced a fall in GFR.

Adolescent↗

Sentinel lymph node biopsy in breast cancer: guidelines and pitfalls of lymphoscintigraphy and gamma probe detection.

BACKGROUND: Sentinel node (SN) biopsy appears to offer an alternative to routine axillary lymph node dissection (ALND) for staging patients with breast cancer. Various techniques have been studied for identifying the SN, using vital blue dye or radioactive colloid, and initial reports are promising. The inherent limitations and pitfalls must be clearly understood before SN biopsy can be implemented in dinical practice. STUDY DESIGN: In a prospective trial, the feasibility of using lymphoscintigraphy and gamma probe detection for performing SN biopsy was studied. In 130 consecutive patients with T1-T2, N0 breast cancer, preoperative lymphoscintigraphy was performed with technetium 99m-colloidal albumin. During ALND, the radioactive axillary SNs were localized by the gamma probe. Histopathologic examination of the harvested SNs was compared with the status of the axillary lymph nodes. RESULTS: Axillary focal accumulations were clearly identified on lymphoscintigraphy in 116 patients (89%). The failure rate was significantly higher in patients who had a previous excision biopsy (36%) than in those with a palpable tumor in situ (4%). Using the gamma probe, radiolabeled axillary SNs were successfully biopsied in 122 patients (94%). Because 18 of these patients did not undergo formal lymphadenectomy, the predictive accuracy of SN biopsy was analyzed in 104 patients. Radioactive nodes revealed metastases in 44 of 104 patients (42%); in 26 of them (59%), these were the only involved axillary nodes. The SN was negative in 60 patients (58%); in one patient the ALND was found to contain metastatic disease (1.7% false negatives). Biopsy of the SN was 98% accurate in predicting the absence of nodal metastases. CONCLUSIONS: There are certain guidelines for performing SN biopsy by lymphoscintigraphy and gamma probe detection. Success depends primarily on an adequate functional capacity of the SN, necessary for sufficient nodal uptake to ensure accurate identification. Lymphoscintigraphy defines the pattern of lymph flow and may prevent failure or false-negative biopsies. Biopsy of the SN is a highly accurate, minimally invasive method of staging patients with breast cancer and can substantially reduce the morbidity and costs of surgical treatment by avoiding unnecessary ALND in the majority of patients.

Axilla↗

Transport and retention of colloidal tracers in regional lymphoscintigraphy in melanoma: influence on lymphatic mapping and sentinel node biopsy.

Sentinel node (SN) biopsy is a staging technique used to select patients for regional lymphadenectomy in melanoma. We compared the two most widely used radioactive tracers, 99mTc-colloidal albumin (99mTc-CA) and 99mTc-sulphur colloid (99mTc-SC), with respect to scintigraphy, success rate in gamma probe guided biopsy and absolute uptake in the SN. Scintigraphy was performed in six volunteers after simultaneous injection of the respective tracers in each leg. Comparison of uptake of both tracers showed a higher uptake on the 99mTc-CA side. The scintigraphic count ratio of SNs labelled with 99mTc-SC compared with 99mTc-CA was 1 to 9 28. Next, 20 patients with biopsy-proven melanoma were randomized for injection of 99mTc-CA or 99mTc-SC followed by SN biopsy. Within 20 min after the injection, focal uptake was seen in all cases of the 99mTc-CA group but in only seven of the 10 patients in the 99mTc-SC group (P < 0.05). Focal accumulations were seen in all patients of both groups after 2 h. Spill to non-SNs was seen in five of the 99mTc-CA patients and three of the 99mTc-SC patients. In all patients the SNs could be retrieved under the guidance of a gamma probe and blue dye. The uptake in the SN was significantly higher (P < 0.001) after the injection of 99mTc-CA (0.92+/-0.40%) compared with 99mTc-SC (0.34+/-0.34%). When dynamic scintigraphy is performed, 99mTc-CA is preferable. SN uptake of 99mTc-SC is less than that of 99mTc-CA but this does not adversely affect the surgical procedure.

Adult↗

Sentinel node biopsy in melanoma patients: dynamic lymphoscintigraphy followed by intraoperative gamma probe and vital dye guidance.

Biopsy of the first tumor-draining lymph node (sentinel node, SN) is bound to become the procedure of choice in regional staging of melanoma patients. A tumor-negative SN virtually excludes lymphatic metastases and obviates the need for lymph node dissection. The aim of this study was to combine the advantages of three known techniques to improve the yield of successful SN biopsies. A total of 150 drainage areas in 135 patients was evaluated. First, preoperative dynamic and static lymphoscintigraphy was performed after injection of technetium 99m colloidal albumin. In all patients one to three focal accumulations, concordant with SNs, were seen in the lymphatic drainage areas, in 97% within 20 minutes from injection of the tracer. Peroperative identification of the SN, 2 to 24 hours after injection of the tracer, was done with a handheld gamma probe to estimate the optimal site for the small incision and to guide preparation. Vital dye was injected just preoperatively and served to facilitate the final identification and biopsy of the SN. A total of 216 SNs were biopsied. Micrometastases were found in 39 SNs in 30 drainage areas, and in 22 of the 30 of the SN was the only node harboring tumor. In 5 of 30 drainage areas, the SN did not contain blue dye and would not have been found without the gamma probe. Up to now (follow-up 233-691 days) no recurrence has developed in the lymphatic drainage areas where the SN was tumor-free. It was concluded that by combining these three techniques the SN could be detected and excised in all patients. The procedure combines a steep learning curve with high sensitivity.

Biopsy, Needle↗

Sodium, blood pressure, and arterial distensibility in insulin-dependent diabetes mellitus.

We investigated 24-hour ambulatory blood pressure and arterial distensibility, a marker of biophysical vessel wall properties, in 32 normoalbuminuric type I diabetic patients and 32 healthy control subjects on diets containing 50 mmol and 200 mmol sodium per day. The increase in daytime diastolic blood pressure from 50 to 200 mmol sodium was significantly higher in the diabetic patients than in the control subjects (2.3+/-4.9 versus 0.2+/-3.7 mm Hg, P<.05). On a high sodium regimen, femoral artery distensibility was decreased in the diabetic patients compared with the control subjects (19.2+/-7.6 versus 24.1+/-9.3 10[-3]/kPa, P<.05). Angiotensin-converting enzyme inhibition in the diabetic patients on a high sodium diet decreased daytime diastolic blood pressure and increased femoral artery distensibility. The blood pressure decrease in response to angiotensin-converting enzyme inhibition correlated significantly with the blood pressure increase to sodium (for 24-hour systolic and diastolic blood pressure, r=.72, P<.001 and r=.76, P<.001). In addition, we found that in the diabetic patients on a high sodium diet, the renal blood flow response to exogenous angiotensin II was not bimodally distributed, as is the case in essential hypertension, in which a subgroup of the patients are characterized by sodium sensitivity of the blood pressure and an abnormal renal blood flow response to exogenous angiotensin II ("nonmodulator phenotype"). These results show that blood pressure in insulindependent diabetes mellitus is sodium sensitive, but that this is not related to the nonmodulator phenotype, and suggest that in IDDM a relatively high sodium intake may be a factor that predisposes to the development of diabetic vascular disease.

Adult↗

Impact of lymphoscintigraphy on sentinel node identification with technetium-99m-colloidal albumin in breast cancer.

UNLABELLED: Identification of the sentinel node by using colloidal tracers and a gamma probe or lymphoscintigraphy could be an effective alternative for the complicated original dye-oriented approach. We studied the sentinel node detection rate using early and delayed imaging in breast cancer patients. METHODS: Thirty-seven patients were imaged 2 hr and 18 hr after peritumoral injection of 99mTc-colloidal albumin. Preoperatively, axillary foci were located with a handheld gamma probe that was also used to isolate radiolabeled nodes from the axillary dissection specimens. The predictive value of the sentinel node for the axillary tumorstatus was evaluated with histological examination. RESULTS: Two and 18 hr after injection, lymphoscintigraphy revealed one to three separate axillary lymph nodes in 33 and 34 patients, respectively. In 30 patients the axillary foci were easily localized with the gamma probe preoperatively. In all 34 patients (92%), with visualized axillary foci, at least one radioactive sample could be retrieved using the gamma probe (total 53 samples). Metastases were found in the sentinel nodes of 11 patients, in seven of 11 being the only tumor-positive lymph node in the axilla. There were no false-negative sentinel nodes. CONCLUSION: The selective targeting and prolonged intranodal retention of 99mTc-colloidal albumin allows successful sentinel node identification in most (92%) patients.

Aged↗

The impact of dynamic lymphoscintigraphy and gamma probe guidance on sentinel node biopsy in melanoma.

In cutaneous melanoma, biopsy of the first tumour-draining lymph node (sentinel node, SN) may replace routine elective lymph node dissection (ELND). Even in experienced hands the original technique using vital dyes fails to localise the SN in 20% of cases. In this study we investigated whether the procedure benefits from lymphoscintigraphy and the use of a gamma probe. In 41 patients technetium-99m-colloidal albumin was injected intracutaneously around the scar of the excised tumour. This was followed by dynamic and late static imaging. The first focal accumulation was assumed to be the SN. In all patients at least one SN was found, in 95% within the first 20 min. By showing multiple or ramifying lymphatic channels, dynamic lymphoscintigraphy differentiated between spill and multiple SNs. In all cases the initial focus retained the highest fraction of radioactivity for at least 18 h. The gamma probe was especially useful in the axilla and neck, where it accurately showed the optimal incision site and facilitated the search for deep-seated nodes. Gamma probe-localised SNs were dye-positive in 93% of cases. The SN contained metastases in 20% of the patients. Only in these patients was ELND performed, which revealed that the SN had been the only metastatic node in four of eight cases. We conclude that dynamic lymphoscintigraphy is essential for SN localisation, that tracer kinetics allow flexible timing of surgery, and that the surgical procedure benefits from use of the gamma probe.

Adolescent↗