PubMed Health⌕ Search

Biomedical subjects

R Pozzi Mucelli

Publications and source records attributed to R Pozzi Mucelli.

At least 19 recordsLinked to original sources

Focal breast lesions with benign appearances. Review of eight breast cancers with initial features of intramammary lymph node.

PURPOSE: The aim of this study was to evaluate whether certain histological types of early breast cancer may share radiographic features with intramammary lymph nodes. MATERIALS AND METHODS: The previous mammograms of patients with histologically proven breast cancer and lesions displaying the morphological features of intramammary lymph nodes were retrospectively reviewed. RESULTS: Retrospective evaluation demonstrated eight breast cancers of varying histological nature--mostly ductal carcinomas not otherwise specified (NOS)--whose early radiographic features were similar to intramammary lymph nodes. CONCLUSIONS: Although uncommon, a lesion with the radiographic features of an intramammary lymph node may hide an early breast cancer. No significant relationship exists between histological type and the presence of such features.

Biopsy, Needle↗

Role of CT and MRI in the preoperative evaluation of auditory brainstem implantation in patients with congenital inner ear pathology.

PURPOSE: The purpose of this study was to evaluate the reliability of computed tomography (CT) and magnetic resonance imaging (MRI) in characterising cochlear nerve anomalies in auditory brainstem implant candidates with congenital hearing loss. MATERIALS AND METHODS: Seventeen patients affected by congenital sensorineural hearing loss were examined by CT and MRI. Inner ear malformations eligible for auditory brainstem implants were classified according to the Casselman classification. All patients subsequently received auditory brainstem implants. RESULTS: Suspected congenital anomalies were confirmed by CT and MRI in all 17 patients. There were 5/17 bilateral cochlear nerve aplasias and 12/17 cochleovestibular anomalies. Of these, 5/12 patients had a common cochleovestibular cavity, 2/12 had bilateral cochlear aplasia and cochlear nerve agenesis, 1/12 had type I incomplete partition, 2/12 had type II incomplete partition and 2/12 had cochlear hypoplasia. CONCLUSIONS: Preoperative CT and MRI assessment of patients with sensorineural hearing loss is reliable. MRI provided additional information, identifying the possible absence of cochlear nerve and excluding other central nervous system (CNS) diseases.

Adolescent↗

Assessment of pelvic endometriosis: correlation of US and MRI with laparoscopic findings.

PURPOSE: The purpose of this study was to evaluate the contribution of ultrasound (US) and magnetic resonance (MR) imaging in the diagnosis and local staging of endometriosis by comparing results with laparoscopic findings. MATERIALS AND METHODS: We evaluated 36 consecutive women with suspected or clinically diagnosed endometriosis. Thirty-two out of 36 patients met the following inclusion criteria: transabdominal and endocavitary (US) examination and MR imaging, followed by laparoscopy performed within 2 weeks. US and MR findings were classified based on location, number and morphology (small nodules, large nodules, laminar lesions, cystic lesions, complex lesions, adhesions, cul-de-sac obliteration). RESULTS: Laparoscopy, considered the gold standard, identified 143 lesions in 32 patients. US detected 101 lesions, and MR detected 92 lesions, which were subsequently divided by morphologic appearance. Sensitivity and specificity of the two imaging techniques in the recognition of the different locations were 58% and 25%, respectively, for US and 56% and 50%, respectively, for MR imaging. Results of the two techniques in the different locations examined were similar, with the exception of lesions in the rectovaginal septum, which were better detected by US, and for adhesions and cul-de-sac obliteration, which were more easily detected by MR. CONCLUSIONS: Both US and MR are accurate in the diagnosis of endometriosis. There are no significant differences in staging of pelvic endometriosis between US and MR. US examination is the primary evaluation in cases of suspected disease and for the rectovaginal septum. MR examination is recommended for correct classification in doubtful cases and in cases of suspected extrapelvic lesions and adhesions.

Adnexal Diseases↗

Focal liver lesions: sinusoidal phase of CEUS.

Ultrasound examination is the first imaging modality for hepatic study in neoplastic and chronic liver diseases. Focal liver lesions frequently cause diagnostic problems in terms of characterization, especially when small and hypoechoic to the rest of the parenchyma. Contrast--enhanced ultrasonography (CEUS) has shown its value in the characterization of focal liver lesions. This study assessed the value of the sinusoidal phase of CEUS with a second-generation contrast agent in the characterization of focal liver lesions to distinguish benign from malignant. Two hundred hepatic lesions with suspicious features at baseline ultrasound were prospectively studied with CEUS. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of the sinusoidal phase in the characterization of benign versus malignant liver lesions were evaluated. Hypoechogenicity of the focal liver lesion, during the sinusoidal phase of CEUS, allowed the diagnosis of malignancy with a sensitivity of 85%, specificity of 88%, positive predictive value of 92%, negative predictive value of 77%, and diagnostic accuracy of 86%. The diagnostic confidence in the diagnosis of malignancy significantly increased, with receiver operating characteristic curve areas from 0.536 for baseline ultrasound to 0.902 for the sinusoidal phase of CEUS.

Adolescent↗

Angiosonography in suspicious breast lesions with non-diagnostic FNAC: comparison with power Doppler US.

PURPOSE: The purpose of this study was to evaluate the accuracy of angiosonography in comparison with colour Doppler ultrasound (US) in the discrimination of suspicious breast lesions with nondiagnostic fine-needle aspiration cytology (FNAC). MATERIALS AND METHODS: Pre-operative Power Doppler US and angiosonography were prospectively performed in 20 suspicious breast lesions with non-diagnostic FNAC. A second-generation US contrast agent was utilised with a high-frequency transducer and a contrast-specific algorithm (low acoustic pressure CnTI). The enhancement characteristics of all lesions were analysed using qualitative and quantitative parameters obtained from time-intensity curves with the different imaging modalities. The final diagnosis was confirmed at pathology in all cases. Microvessel density (MVD) was assessed in the surgical specimen using CD34. RESULTS: The correct assessment of biological behaviour was achieved in all cases by angiosonography (sensitivity of 100%; specificity of 91%) and colour Doppler US (45% sensitivity; 78% specificity). MVD correlated with the biological behaviour. CONCLUSIONS: Angiosonography is more accurate than colour Doppler US in the correct assessment of biological behaviour of suspicious breast lesions.

Adult↗

Doppler ultrasound and contrast-enhanced magnetic resonance angiography in assessing carotid artery stenosis.

PURPOSE: This study prospectively compares Doppler ultrasound (Doppler US) and contrast-enhanced magnetic resonance angiography (CE-MRA) with digital subtraction angiography (DSA) and endarterectomy findings to determine the accuracy in assessing carotid artery stenosis. MATERIALS AND METHODS: Thirty-two patients underwent carotid endarterectomy, 21 studied with Doppler US, CE-MRA and DSA and 11 with Doppler US and CE-MRA. In 41 carotid arteries, the degree of stenosis was analysed with Doppler US and CE-MRA and compared with DSA by using the Spearman rank correlation coefficient. Nine out of 32 endarterectomies were done using the eversion technique, and it was possible to compare Doppler US, CE-MRA and DSA with the specimen measurement. Twenty-three out of 32 endarterectomies were done using the standard technique, and the presence of ulcers was documented. RESULTS: There was a significant Doppler US/DSA (Rs=0.86; p<0.001) and CE-MRA/DSA (Rs=0.81; p<0.001) correlation for the degree of stenosis. The diagnostic accuracy of the three methods was the same (89%). Ulcers were most frequently seen at CE-MRA, with a diagnostic accuracy of 85%. CONCLUSIONS: These data suggest that endarterectomy on the basis of Doppler US and CE-MRA can be considered appropriate. CEMRA was the best noninvasive imaging modality to detect plaque ulceration.

Angiography, Digital Subtraction↗

Branch duct IPMTs: value of cross-sectional imaging in the assessment of biological behavior and follow-up.

Branch duct intraductal papillary mucinous tumors (IPMTs) are increasingly being described and represent a challenge for the physician. Recent imaging modalities, especially computed tomography and magnetic resonance, allow for a correct diagnosis, but IPMTs can manifest with different degrees of cellular atypia so it is very important to be able to establish the biological behavior of the lesion. Sixty-five patients were included in this study: 29 of them underwent surgery, and the other 36 were followed with cross-sectional imaging. Among patients who underwent surgery, 11 had benign lesions and 18 had malignant lesions. Overall sensitivity, specificity, and accuracy in the diagnosis of malignancy for all the cross-sectional imaging techniques were 61%, 81%, and 69%, respectively. Among patients who were followed and had a magnetic resonance cholangiopancreatographic diagnosis of branch duct IPMT with imaging features indicative of benignity, only two showed modifications over the follow-up period. Even considering some important biases (small number of patients and relatively short follow-up), interesting conclusions can be drawn: the imaging diagnosis of malignancy can be trusted, whereas that of benignity cannot be relied upon, but if the signs of malignancy are absent, the slow growth of the lesions justifies watchful follow-up in the correct clinical setting.

Adenocarcinoma, Mucinous↗

Rotational angiography of the carotid artery bifurcation: technical aspects and preliminary results.

PURPOSE: Rotational Angiography (RA), a new modality for performing conventional catheter angiography, enables an accurate evaluation of the artery to be obtained from different points of view by means of the contemporary rotation of the X-ray tube and image intensifier during intrarterial selective injection of contrast media. This paper describes the examination technique and compares the diagnostic accuracy of the RA oblique projections with the data obtained in the antero-posterior (AP) and latero-lateral (LL) projections in the study of the carotid bifurcation. MATERIALS AND METHODS: Thirty patients underwent RA of the supra-aortic vessels to evaluate the degree of a stenosis at the carotid bifurcation suspected at color Doppler imaging. The angiographic examinations were performed on a Philips Integris Allura system able to rotate the arc at a speed of 55 degrees /s with selective catheterisation of both common carotid arteries. RESULTS: The frame showing the greatest degree of stenosis was compared with the frames obtained in the AP and LL projections. 57/60 carotid bifurcations were assessable (3 cases of internal carotid arteries were obstructed). The degree of stenosis evaluated on the most significant of the oblique projections was superior to that shown in the AP and LL projections for 16/30 cases on the right side and for 14/27 cases on the left side. In 4/57 cases (7%) the degree of stenosis was modified from less than 70% to more than 70%. No adverse event was observed due to catheterisation. CONCLUSIONS: RA enables the complete three-dimensional evaluation of the carotid bifurcation, and generally yields more accurate information on the degree of the stenosis in comparison with AP and LL technique. The study was successfully carried out in all cases, however slightly longer examination times due to the setup requirements of the system. This was largely compensated by the quality of the information yielded, which required no additional projections to be performed. Moreover, the high frame rate of 25 frames per second showed the haemodynamic flow through the lesion.

Aged↗

Evaluation of image quality and dose in renal colic: comparison of different spiral-CT protocols.

The aim of this study was to test different technical spiral-CT parameters to obtain optimal image quality with reduced X-ray dose. Images were acquired with a spiral-CT system Philips Tomoscan AVE1, using 250 mA, 120 kV, and 1-s rotational time. Three protocols were tested: protocol A with 5-mm thickness, pitch 1.6, slice reconstruction every 2.5 mm; protocol B with 3-mm thickness, pitch 1.6, slice reconstruction every 1.5 mm; and protocol C with 3-mm thickness, pitch 2, slice reconstruction every 1.5 mm. Two phantoms were employed to evaluate the image quality. Axial images were acquired, then sagittal and coronal images were reconstructed. Finally, the absorbed X-ray dose for each protocol was measured. Regarding image quality, 5-mm-thick images (protocol A) showed greater spatial resolution and lower noise compared with 3-mm-thick images (protocols B and C) on the axial plane; 3-mm reconstructed sagittal and coronal images (protocols B and C) showed an improved image quality compared with 5-mm reformatted images (protocol A). Concerning X-ray dose, the mean dose was: protocol A 19.6 +/- 0.8 mGy; protocol B 14.4 +/- 0.6 mGy; protocol C 12.5 +/- 1.0 mGy. Our study supports the use of thin slices (3 mm) combined with pitch of 1.6 or 2 in renal colic for X-ray dose reduction to the patient and good image quality.

Clinical Protocols↗

[Spiral-CT with multiplanar reconstructions (MPRS) in the evaluation of ureteral neoplasms: preliminary results].

PURPOSE: Urothelial tumors of the upper urinary tract (renal pelvis and ureters) are rare: the most common of these are Transitional Cell Carcinomas (TCC), usually localized in the bladder (75% of cases), whereas only 7-10% arise in the renal pelvis and 2,5-5% in the ureter. Multicentricity is not infrequent and synchronous or metachronous tumors have been reported to develop in 11-13% of patients with upper urinary tract cancer and 2-4% of those with bladder cancer. The presence of additional lesions can change patient management. Clinically these tumors may present with hematuria or flank pain, but sometimes there are no specific clinical findings. Radiological studies play an important role in tumor detection and staging and in follow up. The diagnosis is usually performed by IVU and US, while CT is generally employed in the staging. Our purpose was to verify the role of Spiral CT with Multiplanar Reconstructions (MPRs) in the evaluation of ureteral tumors. MATERIAL AND METHODS: Nine patients with ureteral neoplasms were examined with a single detector spiral-CT, using the following parameters: 120 kV, 200 mA; 5 mm collimation, pitch 1.4, slice reconstruction every 5 mm; image acquisition 2-5 minutes after injection of 120 cc of contrast medium (300 mgI/ml). All the exams were transferred to a separate workstation to obtain curvilinear MPRs. RESULTS: Spiral CT on the axial plane visualized 4 urothelial tumors as concentric ureteral wall thickening; 3 as intraluminal soft tissue masses, with involvement of almost the entire urinary tract, as far as the bladder in 1 case. In other 2 patients there were synchronous lesions which presented both patterns (wall thickening and intraluminal mass). In all cases the lesions exhibited moderate enhancement after c.m. injection. Medium- to high-grade hydronephrosis above the tumors was always present. On MPRs both ureteral involvement and dilated, urine-filled upper urinary tract were clearly represented on coronal and sagittal oblique planes; these images allowed to visualize the craniocaudal extension of short or long lesions, and to detect multicentricity. DISCUSSION: The radiological diagnosis of ureteral tumors is usually performed by IVU, US and CT. IVU allows to visualize the tumors as filling defects or irregular narrowing of the ureteral lumen. IVU however is unable to show the real extent of the tumor in obstructive disease or in nonfunctioning kidney. US visualizes the lesion as an echoic mass in the lumen, although it is sometimes difficult to differentiate neoplastic lesions from other filling defects and to visualize the entire ureteral tract. CT is generally employed in the staging of ureteral tumors. CT findings are usually very useful for distinguishing ureteral neoplasms from other filling defects based on their attenuation and enhancement characteristics. Spiral CT with MPRs allows to obtain panoramic views of the urinary tract; these images are more effective than those of IVU, because of their capability to show the longitudinal extension of the lesion and the presence of multicentric tumors. Furthermore with MPRs it is possible to visualize the ureteral tract distal to the lesion, overcoming the limitations of IVU in nonfunctioning kidney or obstructive disease. CONCLUSIONS: Spiral CT with MPRs is useful in the evaluation of ureteral tumors as it is capable of visualizing the whole extension of the lesion and the presence or absence of multicentric lesions, which can change patient management.

Aged↗

[Ultrasonography plus direct radiography of the abdomen in the diagnosis of renal colic: still a valid approach?].

PURPOSE: The authors analyze whether the imaging approach consisting of ultrasonography and plain film in patients with renal colic is still of value when urography is replaced by unenhanced helical CT (UHCT) in unsolved cases. MATERIAL AND METHODS: Eight hundred and three consecutive patients were investigated with US following hydration and KUB, 164 of whom (20.4%) subsequently underwent UHCT (42 with the aim of mapping the excretory pathway and 122 (15.2%) because US and KUB were not considered as fully diagnostic). RESULTS: The 42 patients with detectable ureteral stone (plus possible hydronephrosis) on KUB + US and subsequently examined by UHCT to plan interventional treatment all had a positive UHCT examination. In 62 patients the diagnosis following KUB + US was uncertain (possible stone or possible hydronephrosis) and UHCT depicted the stone and/or the hydronephrosis in 34. In 60 patients the combination of KUB + US was negative but colic recurred and UHCT was positive in 17 patients. DISCUSSION: The comparison of the present results with a previous study in which KUB and US were followed by IVU in unsolved cases underscores the value of the first approach with KUB and US. The need for further diagnostic investigations when KUB + US are either not conclusive or negative and colic recurs is also confirmed. On the basis of our present data and in agreement with the literature IVU can be safely replaced by UHCT. CONCLUSIONS: It is authors' opinion that in settings where KUB, US and UHCT are available throughout the 24 hr the approach consisting of KUB plus US and UHCT in unsolved cases can be preferred in view of its on lower cost and above all lower X-ray dose to patients as compared to UHCT as the sole investigation.

Colic↗

[Effective dose in X-ray examinations: comparison between spiral CT and urography in the study of renal colic].

AIM: The aim of this study was to calculate the effective dose in patients with renal colic undergoing spiral CT examination and IVU examination, and to verify the ability of the systems to measure the effective dose. MATERIAL AND METHODS: Dose measurements were carried out for both diagnostic techniques by employing an anthropomorphic phantom with thermoluminescence detectors (TLDs) fitted inside the phantom. The data so obtained were compared with dose estimations based on published tables, which allow to obtain the effective dose on the basis of the experimental value of common dose indicators, the performance of the equipment and the setting of the acquisition parameters for such examinations. RESULTS: The absorbed dose inside the phantom had an homogeneous distribution during the spiral CT examination, while during the IVU there were significant differences in the absorbed dose between different zones of the body, due to the geometry of the x-ray beam. The mean effective dose, which corresponds to the average of values absorbed by males and females, measured by TLD dosimeters for spiral CT examination was 3.3 time that for IVU. For both spiral CT and IVU the dose to the male was significantly lower than that to the female, owing to the anatomic position of female gonads that are completely exposed to the x-ray radiations during the study, while male gonads lie outside of the exposed area. Both methods for estimating the effective dose in spiral CT, based on CTDI value, significantly underestimated the value derived from experimental TLDs measurement. The evaluation of effective dose in IVU, based on the measurement of the skin dose in air, overestimated the measurement performed by TLDs. DISCUSSION AND CONCLUSIONS: Dose measurement performed by TLD dosimeters fitted inside an anthropomorphic phantom has the advantage of calculating experimentally the absorbed dose in different anatomic districts. However, the method is quite difficult, and introduces some imprecisions due to the simplified morphology of the phantom and the measuring system of TLDs (+/- 10%). Another possibility is to make theoretical estimations on the basis of simple dose measurements. Also these methods are affected by many factors that may introduce imprecisions, such as the patient geometry which has a considerable effect on the dose distribution inside the body. Therefore the methods of measurement based on CTDI value can provide only rough estimations of effective dose. The same considerations can be applied to IVU; in this case the theoretical estimations are based on skin dose measurements, which are very accurate but cannot foresee the behaviour of x-rays inside the patient. As regards the diagnostic procedures evaluated, the gonadic absorbed dose has a greater effect on the effective dose value as a consequence of the weight tissue ratio Wt. In this respect we should underline that, while female gonads are completely irradiated during spiral CT and IVU examinations, the male gonads are exposed only to diffuse radiation; this entails a great difference between the effective dose to the male and that to the female. For this reason the effective dose should be expressed not only for the average man (that is the mean value between males and females), but also distinguishing by patient sex. Although the comparison of different evaluating methods confirmed the difficulties in obtaining the exact effective dose, all the measurements performed with IVU and spiral CT showed that the effective dose for CT is 3.3 times that for IVU. However, the excellent image quality obtained by spiral CT and the high intrinsic contrast of stones probably makes it possible to reduce the dose with this technique, preserving an acceptable quality of the diagnostic images.

Colic↗

[Colonoscopy with computed tomography with volume reconstruction. The results and a comparison with endoscopy and surgery].

PURPOSE: Virtual CT colonoscopy is a novel technique whose diagnostic accuracy and clinical yield are currently investigated. Several studies have shown its capabilities in detecting colon and rectal cancers. We report the results of a preliminary experience with the volume rendering technique and compare CT colonoscopy with endoscopy and surgery. MATERIAL AND METHODS: Our series consisted of 25 patients with colon cancer confirmed at endoscopy and/or surgery. All examinations were carried out with a spiral CT scanner Philips Tomoscan AVE1. Intestinal preparation was adequate in all patients, consisting in gas insufflated immediately before acquisition, after the injection of 100 mL iodinated contrast agent. All examination were performed in prone position using axial 5 mm slices with 5 mm table feed (pitch 1) and 2 mm reconstruction index; 120 kV and 200-250 mA were used. Images were transferred to a workstation (Easy Vision, Philips, release 4.2.1.1) for processing. We acquired multiplanar (MPR) and virtual endoscopic images with volume rendering; the selected threshold was -250 to -600 Hounsfield Units. Virtual endoscopic images could be obtained in 23 of 25 cases. The results of the radiological study were compared with endoscopic and surgical findings in 25 and 17 cases, respectively. RESULTS: Endoscopy and surgery detected 46 lesions: 29 were malignant and 17 benign. Axial CT and MPR alone detected 35 lesions (76%), 29 of them malignant and 6 benign. The 11 benign lesions missed by axial CT ranged 6-8 mm in diameter. There were no false positives. CT colonoscopy alone detected 66 lesions, but 22 of them were false positive due to residual stool in the colon (21 cases) and to residual barium in the colon (1 case). Combining CT colonoscopy and axial and MPR images enabled to correct the false positive diagnoses made by CT colonoscopy alone and to decrease the false negative ratio of axial and MPR images. Forty-one of 44 lesions (93%) were detected. Thirty-seven lesions were found in the 17 surgical patients; 34 of them were correctly identified combining CT colonoscopy and axial and MPR findings, while endoscopy detected only 31 lesions. Thus, CT had 92% sensitivity, versus 83% of fiberoptic endoscopy. CONCLUSION: In this preliminary experience volume rendering CT colonoscopy exhibited high sensitivity in detecting colon cancers, but their correct evaluation and characterization can be obtained if axial and MPR studies are combined. Further investigation and technological developments are necessary to define the yield of this new technique.

Adenocarcinoma↗

[Dentascan computed tomography of the mandibular incisive canal. Its radiologic anatomy and the therapeutic implications].

PURPOSE: To stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. MATERIALS AND METHODS: January through December 1998, sixty patients unselected by age and gender were submitted to mandibular CT. Axial slices were acquired with 1-1.5 mm thickness and 1 mm table feed, and the images were then reformatted with a dedicated dental software. Both the conventional and the Helical techniques were used. RESULTS: The incisive canal appears on Dentascan transverse reconstructions as a round low-density area within mandibular trabecular bone, which is surrounded by a higher-density rim representing the canal walls. This anatomical structure originates from the mental foramen and continues mesially to the mental symphysis. The mandibular canal was visualized in 95% of cases bilaterally (57/60); the incisive canal was depicted on the left side in 41.6% of cases (25/60) and on the right side in 51.6% (31/60). CONCLUSIONS: The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth.

Female↗

[Comparison of magnetic resonance Spin-echo sequences and fat-suppressed sequences in bone diseases].

Thirty-two patients affected with skeletal conditions were examined with MRI using Short TI Inversion Recovery sequence and Spectral Presaturation with Inversion Recovery (SPIR) sequence as well as Spin-Echo (SE) T1-weighted sequence and Fast Spin-Echo (FSE) T2-weighted sequence to compare their value in the assessment of skeletal lesions. SPIR sequence was performed after intravenous injection of Gd-DTPA. The lesions included primary bone tumors (10 cases: 1 osteosarcoma, 1 periosteal sarcoma, 1 Ewing's sarcoma, 1 chondrosarcoma, 2 non-ossifying fibromas, 1 chondroma, 1 chondromyxoid fibroma, 1 desmoplastic fibroma and 1 bone cyst), metastases (7 cases: 3 prostate, 3 breast, 1 lung-squamous cell carcinoma), infections (12 cases: 9 osteomyelitis, 3 spondylodiscitis), sacroiliitis (1 case) and posttraumatic bone bruise (2 cases of bone marrow edema). The four sequences were compared by using both qualitative and quantitative evaluation. Qualitative evaluation showed that STIR sequence was better than SPIR sequence (performed with Gd-DTPA) for lesion conspicuity (p < .016) and for signal intensity uniformity (p < .03). Compared with SE T1 and FSE T2 sequences, fat-suppressed sequences were superior for conspicuity, margins, and extension of the lesions (range of p < .001-.017). Only SPIR with Gd-DTPA sequence, compared with SE T1 sequence for lesion conspicuity was not statistically significantly different. Quantitative evaluation showed statistically significant higher values of percent contrast (%C) and contrast-to-noise ratio (C/N) for STIR sequence compared with SPIR sequence (%C p < .004; C/N p < .040). This study suggests that STIR sequence and SE T1-weighted sequence provide high sensitivity in lesion detection and good anatomical definition. The use of a fat-suppressed sequence with Gd-DTPA can be useful for lesion characterization.

Adolescent↗