A dynamometer for evaluation of dynamic muscle work.

The validation of a new dynamometer for evaluation of dynamic muscle work is presented. The device was based on a precise measurement of load displacements of any machine using gravitational loads as external resistance. It allowed, through a sensor consisting of an infrared photo interrupter, the calculation of velocity, force and power during concentric, eccentric and stretch-shortening cycle activity. To validate the dynamometer 33 male and female track and field athletes (12 throwers and 21 jumpers) participated in the study. The throwers (4 women and 8 men) were asked to perform half-squat exercises on a slide machine with a load of 100% of the subject's body mass. The day-to-day reproducibility of half-squat exercises gave a correlation coefficient of r = 0.88, 0.97 and 0.95 for average push-off force (AF), average push-off velocity (AV), and average push-off power (AP) respectively. Comparison of half-squat measurements was performed against jumping and running test evaluation by the jumpers (7 women and 14 men). The interrelationships among the different variables studied demonstrated a strong correlation between AF, AV and AP and sprinting and jumping parameters (r = 0.53-0.97; P < 0.05-0.001). Using values of AF, AV and AP developed in half-squat exercises executed with different loads, ranging from 35% to 210% of the subject's body mass, it was also possible to establish the force-velocity and power-velocity relationships for both male and female jumpers. In any individual case, the maximal error due to the measurement system was calculated to be less than 0.3%, 0.9% and 1.2% for AF, AV, and AP respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The influence of extra load on the mechanical behavior of skeletal muscle.

Eleven international jumpers and throwers engaged in year round training were divided into experimental (n = 6) and control (n = 5) groups. The experimental group was tested before and after a 3 weeks simulated hypergravity period, and again 4 weeks after the hypergravity period. The high gravity condition was created by wearing a vest weighing about 13% of the subjects body weight. The vest was worn from morning to evening including the training sessions, and only removed during sleep. The daily training of all subjects consisted of classical weight training and jumping drills. No changes in the ordinary training program were allowed in the experimental group, except for the use of the vest. Vertical jumps, drop jumps and a 15 s continuous jumping test were used to measure the explosive power characteristics of the subjects. After the hypergravity period the experimental subjects demonstrated significant (5-10%, P less than 0.05-0.01) improvements in most of the variables studied: however, 4 weeks after cessation of the high gravity period they tended to return towards the starting values. No changes were observed in the results of the control group. The improvement observed in the experimental subjects was explained as fast adaptation to the simulated high gravity field. It is suggested that adaptation had occurred both in neuromuscular functions and in metabolic processes.

Adult↗