PubMed Health⌕ Search

Biomedical subjects

R Price

Publications and source records attributed to R Price.

At least 19 recordsLinked to original sources

The influence of surfactant on PLGA microsphere glass transition and water sorption: remodeling the surface morphology to attenuate the burst release.

PURPOSE: The stability of protein unloaded and loaded poly(lactic-co-glycolic acid) (PLGA) microspheres fabricated with surfactant was challenged through exposure to environmental conditions of different relative humidity. METHODS: Polyvinyl alcohol (PVA) or Triton X-100 was added to the primary emulsion of the double-emulsion solvent evaporation technique. After storage at ambient humidity and 75% relative humidity, the mechanical stability of the polymer was tested to reveal PLGA chain mobility using differential scanning calorimetry. Subsequent surface modifications were examined by atomic force microscopy (AFM), and protein release profiles were collected. RESULTS: Residual amounts of PVA and particularly Triton X-100 raised the hydrophilicity of the microspheres. When exposed to ambient humidity or 75% relative humidity, PVA and Triton X-100 had, respectively, an antiplasticizing and a plasticizing effect upon PLGA, and both led to physical aging. The high-resolution AFM imaging of microspheres containing model protein and Triton X-100 showed that the depth of the surface pores was reduced when exposed to 75% relative humidity, and the initial burst release subsequently decreased. CONCLUSION: These studies suggested that the mechanical stability of PLGA was influenced by the addition of surfactants, which, depending on the formulation, led to surface pore remodeling under high humidity, reducing the initial burst release while maintaining the spherical integrity of the microsphere.

Delayed-Action Preparations↗

Investigation into the influence of polymeric stabilizing excipients on inter-particulate forces in pressurised metered dose inhalers.

Colloid probe atomic force microscopy (AFM) was utilised to quantify the cohesive forces of salbutamol sulphate in a model non-pressurised fluorinated liquid (mHFA), in the presence of increasing concentrations of poly(ethylene glycol) (PEG; molecular weight (MW) 200, 400 and 600). In addition, samples of PEG 400 (0.05-0.5%, v/w), were analysed in the presence of 0.001% (w/w) of poly(vinyl pyrrolidone) (PVP). In the absence of any stabilizing agents, strong attractive forces were present between particles. Increasing the concentration of the different MW PEG solutions in the mHFA system (up to 0.5%, v/w), significantly decreased the force of interaction (ANOVA, p<0.05). The decrease in cohesion was particularly evident at very low concentrations of PEG (0.05-0.1%, v/w). Further data analysis (p<0.05) suggested that the reduction in the force of cohesion was dependent on the concentration and molecular weight of PEG. The addition of low concentration of PVP to the PEG 400-mHFA system had the most significant influence on drug particle cohesion. In the presence of PVP, increasing addition of PEG 400 (0.05-0.5%, v/w) to the mHFA, resulted in no significant reduction in the force of cohesion (p>0.05). Clearly, an understanding of the conformation of polymer molecules at interfaces is of vital importance when controlling the stability/flocculation behaviour of sterically stabilized pMDI suspensions. In this context, the use of the colloid probe AFM technique has provided a quantitative insight into the interactions of these complex systems and may be an invaluable asset during the early phase of formulation product development.

Albuterol↗

Human T-lymphotropic virus type 1-associated myelopathy/tropical spastic paraparesis: viral load and muscle tone are correlated.

Human T-lymphotropic virus type 1 (HTLV-1) infections are associated with varying degrees of HTLV-1 viral load and spasticity. Increased viral load is associated with higher risk of developing HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP). The authors performed a cross-sectional study of 24 people with HAM/TSP in Lima, Perú, to determine if higher HTLV-1 viral load was correlated with increased muscle tone, measured with a device providing quantitative spasticity assessment (QSA). Median HTLV-1 viral load was 17.0 copies/100 peripheral blood mononuclear cells and QSA value was 39.9 Newton-meters/radian. HTLV-1 viral load was significantly correlated with QSA value (Spearman rho = .48, P = .02), suggesting viral load may play a role in expression of symptomatic neurologic disease. Longitudinal studies are needed to determine if treatments that reduce viral load will reduce muscle tone.

Cross-Sectional Studies↗

The use of the long gamma nail in proximal femoral fractures.

The results of 100 'Long Gamma Nails' (LGN) inserted in 97 patients, for the treatment of complex proximal femoral fractures and pathological lesions, are reported. The mean patient age was 74 (16-98). Seven significant complications occurred; four lag screws cut out, one broken nail, one infected non-union and one peri-prosthetic fracture. Five patients underwent revision either to total hip arthroplasty or exchange nailing. Seventy patients had follow-up of greater than 2 months (mean 10.8 months). Success was defined as stability of the fracture until union or death; this was achieved in 85% of cases. The mortality was 10% at 30 days and 25% at 1 year. The complication rate fell with increasing experience. Complex proximal femoral fractures are difficult to treat with all implants demonstrating high complication rates. The long gamma nail allowed early weight bearing and was effective in 85% of cases. Malpositioning of the implant should be avoided, as this was the leading cause of failure. Surgeon experience is an important factor but training of surgeons does not adversely affect outcome.

Adolescent↗

Application of Bruchin B to pea pods results in the up-regulation of CYP93C18, a putative isoflavone synthase gene, and an increase in the level of pisatin, an isoflavone phytoalexin.

Bruchins, mono and bis (3-hydroxypropanoate) esters of long chain alpha,omega-diols, are a recently discovered class of insect elicitors that stimulate cell division and neoplasm formation when applied to pods of peas and certain other legumes. Differential display analysis resulted in the identification of an mRNA whose level was increased by the application of Bruchin B to pea pods. The corresponding amplification product was cloned and sequenced and a full length cDNA sequence was obtained. This cDNA and the gene from which it was derived were assigned the name CYP93C18 based upon sequence similarities to the cytochrome P450 mono-oxygenase CYP93C subfamily, which contains isoflavone synthase genes from legumes. RNA gel blots and quantitative RT-PCR demonstrated that expression of CYP93C18 increased within 8 h of bruchin treatment to a maximum of 100-200-fold of the level in untreated pods, and then declined. The up-regulation of CYP93C18 was followed by an increase in the level of the isoflavone phytoalexin, pisatin. Pisatin was detectable in the bruchin-treated pods after 16 h and reached a maximum between 32 h and 64 h. This, the first report of induction of phytoalexin biosynthesis by an insect elicitor, suggests that Bruchin B not only stimulates neoplasm formation, but also activates other plant defence responses.

Amino Acid Sequence↗

Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer.

The purpose of this work is to investigate the accuracy of dose calculation of a commercial treatment planning system (Corvus, Normos Corp., Sewickley, PA). In this study, 30 prostate intensity-modulated radiotherapy (IMRT) treatment plans from the commercial treatment planning system were recalculated using the Monte Carlo method. Dose-volume histograms and isodose distributions were compared. Other quantities such as minimum dose to the target (D(min)), the dose received by 98% of the target volume (D98), dose at the isocentre (D(iso)), mean target dose (D(mean)) and the maximum critical structure dose (D(max)) were also evaluated based on our clinical criteria. For coplanar plans, the dose differences between Monte Carlo and the commercial treatment planning system with and without heterogeneity correction were not significant. The differences in the isocentre dose between the commercial treatment planning system and Monte Carlo simulations were less than 3% for all coplanar cases. The differences on D98 were less than 2% on average. The differences in the mean dose to the target between the commercial system and Monte Carlo results were within 3%. The differences in the maximum bladder dose were within 3% for most cases. The maximum dose differences for the rectum were less than 4% for all the cases. For non-coplanar plans, the difference in the minimum target dose between the treatment planning system and Monte Carlo calculations was up to 9% if the heterogeneity correction was not applied in Corvus. This was caused by the excessive attenuation of the non-coplanar beams by the femurs. When the heterogeneity correction was applied in Corvus, the differences were reduced significantly. These results suggest that heterogeneity correction should be used in dose calculation for prostate cancer with non-coplanar beam arrangements.

Computer Simulation↗

Quantitative assessment of spasticity in human T-cell lymphotropic virus type I-associated myelopathy/tropical spastic paraparesis.

People with human T-cell lymphotropic virus type I-associated myelopathy/tropical spastic paraparesis (HAM/TSP) develop spasticity. The authors examined 34 patients with HAM/TSP in Perú using a device that measures tone in the gastroc-soleus-Achilles tendon unit and provides a quantitative spasticity assessment (QSA). Tone in the 34 patients was more than double that of women with asymptomatic HTLV-I infection. The device may help to track progression in HTLV-I infection.

Adult↗

Paradoxical embolization via a patent foramen ovale following acute pulmonary embolism.

The foramen ovale is usually obliterated following establishment of the adult circulation but remains patent in 25% of individuals. This potential communication between the venous and arterial circulations can allow thromboembolic material to bypass the lungs and enter the systemic circulation. We report two cases of paradoxical embolization through a patent foramen ovale following acute large pulmonary embolism (PE) and discuss the factors that predispose to paradoxical embolization following PE.

Adult↗

Atlas: standard diagnostic tests for an unusual fracture.

The case is reported of an unusual atlas fracture with no reports of such an injury in the literature. The diagnosis of this injury emphasises the importance of simple clinical decision instruments, and systematic interpretation of investigations.

Adult↗

In-line assessment of pulmonary drug delivery using light obscuration.

A candidate optical technology for characterisation of the value and quality of the drug dose delivered to a patient from an inhaler is examined. The theoretical reasoning behind the design of this technology is presented with reference to the optical scattering of the drug cloud. A technical implementation is presented; based upon the light obscuration signature, observed in the delivery path during drug delivery. Dose evaluation studies are reported, performed on different types of drug formulations using regulatory testing procedures and the proposed optical sensing system. Further applications of this technology are discussed in relation to the identification and evaluation of inhaler-drug formulation combinations, which are most suitable for particular patients.

Administration, Inhalation↗

Stereotactic IMRT for prostate cancer: dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT.

The focus of this work is the dosimetric impact of multileaf collimator (MLC) leaf width on the treatment of prostate cancer with intensity-modulated radiation therapy (IMRT). Ten patients with prostate cancer were planned for IMRT delivery using two different MLC leaf widths--4mm and 10mm--representing the Radionics micro-multileaf collimator (mMLC) and Siemens MLC, respectively. Treatment planning was performed on the XKnifeRT2 treatment-planning system (Radionics, Burlington, MA). All beams and optimization parameters were identical for the mMLC and MLC plans. All the plans were normalized to ensure that 95% of the planning target volume (PTV) received 100% of the prescribed dose. The differences in dose distribution between the two different plans were assessed by dose-volume histogram (DVH) analysis of the target and critical organs. We specifically compared the volume of rectum receiving 40 Gy (V40), 50 Gy (V50), 60 Gy (V60), the dose received by 17% and 35% of rectum (D17 and D35), and the maximum dose to 1 cm3 of the rectum for a prescription dose of 74 Gy. For the urinary bladder, the dose received by 25% of bladder (D25), V40, and the maximum dose to 1 cm3 of the organ were recorded. For PTV we compared the maximum dose to the "hottest" 1 cm3 (Dmax1 cm3) and the dose to 99% of the PTV (D99). The dose inhomogeneity in the target, defined as the ratio of the difference in Dmax1 cm3 and D99 to the prescribed dose, was also compared between the two plans. In all cases studied, significant reductions in the volume of rectum receiving doses less than 65 Gy were seen using the mMLC. The average decrease in the volume of the rectum receiving 40 Gy, 50 Gy, and 60 Gy using the mMLC plans was 40.2%, 33.4%, and 17.7%, respectively, with p < 0.0001 for V40 and V50 and p < 0.012 for V60. The mean dose reductions for D17 and D35 for the rectum using the mMLC were 20.4% (p < 0.0001) and 18.3% (p < 0.0002), respectively. There were consistent reductions in all dose indices studied for the bladder. The target dose inhomogeneity was improved in the mMLC plans by an average of 29%. In the high-dose range, there was no significant difference in the dose deposited in the "hottest" 1 cm3 of the rectum between the two plans for all cases (p > 0.78). In conclusion, the use of the mMLC for IMRT of the prostate resulted in significant improvement in the DVH parameters of the prostate and critical organs, which may improve the therapeutic ratio.

Equipment Design↗

Daily target localization for prostate patients based on 3D image correlation.

There are several localization techniques that have been used for prostate treatment. Recently, the potential use of a variety of CT-based equipment in the treatment room has been discussed. The goal of our study was to develop an automated procedure for daily treatment table shift calculation based on two CT data sets: simulation CT data and localization CT data. The method suggested in this study is a 3D image cross-correlation of small regions of interest (ROI) within the two data sets. The relative position of the two ROIs with respect to each other is determined by the maximum value of the normalized cross-correlation function, calculated for all possible relative locations of the two ROIs. After the best match is found the shifts are given by the vector connecting the treatment isocentre and the planning isocentre (both determined by the radio opaque fiducial markers on the patient's skin). The results have been compared with shifts calculated through manual fusion. The shift differences, averaged over 17 statistically independent shift calculations, are less then 1 mm in the lateral and longitudinal directions, and about 1 mm in the AP direction. The impact of image noise on the performance of the algorithm has been tested. The results show that the algorithm accurately adjusts for target positional changes even with Gaussian noise levels as high as 20% inserted.

Algorithms↗

Clinical implementation of intensity-modulated tangential beam irradiation for breast cancer.

A Monte Carlo based intensity-modulated radiation therapy (IMRT) treatment planning system has been developed and used for breast treatment. An iterative method was used for optimization to generate IMRT plans and a step-and-shoot technique was used for beam delivery. The patient setup and incident beam directions were the same as those for conventional tangential photon treatment. The weights for the opposed beamlets in the two tangential beams were determined first by the doses at the depths of the maximum dose at both sides to minimize hot spots. The intensity of an individual beamlet pair was then optimized based on the dose at the midplane. Fine tuning was made to achieve optimal target dose uniformity and to reduce the dose to the heart when necessary. The final dose calculations were performed using the Monte Carlo method and the plans were verified by phantom measurements. The dose distributions and dose-volume-histograms of IMRT plans were compared with those of conventional plans that were generated using a commercial treatment planning system and recalculated using an in-house Monte Carlo system for the first 25 patients. The dose comparisons showed that the percentage volume receiving more than 95% of the prescription dose (V95) and the percentage volume receiving more than 100% of the prescription dose (V100) for the clinical target volume (CTV) of IMRT plans were about the same as those of conventional plans. The percentage volume receiving more than 105% of the prescription dose (V105) for the CTV was reduced from 23.1% to 7.9% on average. The percentage volume of the lung receiving more than 20 Gy dose (V20 Gy) during the entire treatment was reduced by about 10%. The percentage volume of the heart receiving more than 30 Gy dose (V30 Gy) is reduced from 3.3% to 0.3%. Further studies revealed that a less than 5 degrees change in couch angle and collimator angle at patient setup had no significant effect on the dose coverage of CTV but had significant effect on the dose to the lung and heart. The study on the effect of beam spoiler showed that it increased the dose at the buildup region by 0- 13% that varies with location. The machine output linearity and stability for small monitor unit delivery of Siemens accelerators used for this study was checked and found to be suitable for breast IMRT. The total effect of variations was calculated to be less than 1% for typical breast treatments. The beam delivery time was increased by about 2 min compared with conventional tangential treatments. The whole treatment including patient setup and beam delivery can be completed in a 15 min slot. The IMRT technique has been proven practical for breast treatment clinically. The results showed that tangential IMRT improved the dose homogeneity in the breast and reduced the dose to the lung and heart.

Algorithms↗

Congenic mice reveal sex-specific genetic regulation of femoral structure and strength.

Genetic linkage studies in C3H/HeJ (C3H) and C57BL/6J (B6) mice identified several chromosomal locations or quantitative trait loci (QTL) linked to femoral volumetric bone mineral density (vBMD). From QTL identified on chromosomes (chr) 1, 4, 6, 13, and 18, five congenic mouse strains were developed. In each of these mice, genomic DNA from the QTL region of the donor C3H strain was transferred into the recipient B6 strain. Here we report the effects of donated C3H QTL on femoral structure, cortical vBMD and bending strength. Femoral structure was quantified by the polar moment of inertia (Ip) at the mid-diaphysis, which reflects the bending or torsional rigidity of the femur. Although the C3H progenitor mice have a smaller Ip than B6 progenitor mice, the congenic mice carrying the C3H segment at Chr 4 had significantly increased Ip in both males and females, giving these mice stronger femora. In female mice from the congenic Chr 1 strain, Ip was increased whereas male mice from the Chr 1 strain had smaller femoral cross-sections and significantly reduced Ip. This sex-specific effect on femoral structure was seen to a lesser extent in Chr 18 congenic mice. In addition, cortical vBMD was measured using peripheral quantitative computed tomography. Cortical vBMD was similar among most congenic strains except in Chr 6 congenic mice, where cortical vBMD was significantly less in females, but not in males. We conclude that (1) chromosomal QTL from C3H mice, which are genetically linked to total femoral vBMD, also regulate femoral structure; (2) the QTL on Chr 4 improves femoral structure and strength; (3) QTL on Chr 1 and 18 impart sex-specific effects on femoral structure; and (4) the QTL on Chr 6 imparts a sex-specific effect on cortical vBMD and femoral strength.

Animals↗