In vitro survey of low energy laser beam penetration in compact bone.

The laser used in this study (NEURALASE R1) is a light-emitting diode which emits continuous or modulated impulsional signals in the near infra-red (approximately 850 nm). The power emitted varies between 1 and 11 mW. The instrument is placed at a fixed distance from a photovoltaic sensor whose voltage response is a linear function of the received luminous power. The voltage variations are studied as functions of the thickness of the compact bone interposed between the output of the laser and the diode. On semilogarithmic paper, we find a curve of two linear segments having different slopes. The first (between 0 and 1 mm of bone), of very sharp incline, is most probably due to an important reflexion on the bone surface; the second, with a slight incline, corresponds to the absorption which is exponential. Moreover, if the ray enters in the cortico-medullar direction, the second slope is sharper than in the case of a longitudinal penetration following the diaphyseal texture. A power of 10 mW gives a maximal penetration of about 18 mm in the bone axis direction and approximately 6 mm in the cortico-medullar direction. For eventual therapeutic indications, it is necessary to take account of reflexion on the bone surface as well as the direction of the beam in relation to the bone texture, since these two elements interfere in the diffusion of the stimulation.

Bone and Bones↗

An electrocapillary flowmeter usable as a quantitative sweat detector.

A quantitative sweat detector was devised as part of a noninvasive portable warning apparatus intended for the surveillance of unstable insulin-treated diabetics who may have nocturnal hypoglycemic attacks. The sweat sensor consists of a pair of electrodes embedded in a porous material that is infiltrated under capillary drive by sweat as it oozes out of the skin. It was shown that the detector is almost insensitive to insensible perspiration but undergoes graded variation of impedance as it is filled with sweat. It thus works as a transducer of sweat flux (flow rate through unit skin area) as long as the porous material is not saturated. This device has already proved useful as a hypogycemic alarm and could certainly be used for the measurement of sweating rate in place of more cumbersome devices involving ventilated chambers.

Adult↗