Validation of the AMPFlSTR SGM plus system for use in forensic casework.

The AMPFlSTR((R)) SGM Plus system is a commercially available STR multiplex produced by Applied Biosystems, a division of Perkin Elmer, Foster City, California, USA that supersedes SGM. The multiplex contains the six SGM loci, amelogenin and four additional loci. These additional loci are D3S1358, D19S433, D16S539 and D2S1338. Consequently, the match probability is significantly improved (conservatively quoted as 1 in 10(9) for reporting a full profile match). The system was subjected to validation. For example, ageing and degradation studies demonstrated semen stains to be the most stable evidence type, whereas buccal scrapes were the least stable. An apparent rise in the sensitivity increases the chance of obtaining successful results from the more difficult samples submitted for analysis. Two of the new loci (D3S1358 and D19S433) are low molecular weight (between 100 and 150 base pairs); this improved the success rates of the degraded samples where high molecular weight loci may drop out. Of 26 non-primates tested, four gave results that appeared as single peaks and were unlikely to cause interpretation problems. None of the 19 micro-organisms tested gave discernible results. Extensive casework and simulated casework studies demonstrated that SGM and SGM plus results were comparable. There was one example of a null allele (primer binding site mutation) recorded at the HUMFIBRA locus (in both systems). However, a concordance study of 1000 samples using both SGM and SGM plus did not demonstrate any differences in typing.

Alleles↗

Analysis of multiplexed short tandem repeat (STR) systems using capillary array electrophoresis.

The profiling of polymorphic short tandem repeat (STR) markers is being applied to human identification, parentage testing and genetic mapping. Reliable genotyping of these markers is facilitated by polymerase chain reaction (PCR) amplification and high-resolution electrophoretic separation. Capillary array electrophoresis (CAE) offers very rapid, high-resolution separation of the amplified DNA and potential for automated sample processing not realized employing conventional slab-gel electrophoresis. The use of CAE to type DNA samples amplified at 11 genetic loci in multiplex profiles is presented. Two sets totaling 208 samples were amplified in a multiplex fashion using AmpFlSTR-Blue or AmpFlSTR-Green I and analyzed in a blind study using CAE. With the exception of one sample, the CAE genotyping results were in complete agreement with results obtained using a single-capillary system or two slab-gel electrophoresis systems. The sample, genotype TH01 7/10, migrated similar to TH01 6.3/9.3 allele sizes, which suggested a potential band migration shift. The recommended approach to such an observation is to analyze the sample again. The sample was rerun and correct genotype verified. Allelic ladder samples were analyzed multiple times by CAE to determine sizing accuracy and precision. The sizing of over 240 allelic ladder samples yielded an average within-run precision of +/- 0.13 bp and between-run precision of +/- 0.21 bp for fragments up to 350 bp. The CAE protocols permit processing of up to 96 multiplex STR samples in under 70 min.

Alleles↗

Validation of highly discriminating multiplex short tandem repeat amplification systems for individual identification.

Short tandem repeat (STR) loci are routinely employed for individual identification. WE have examined the performance and reproducibility of a highly informative co-amplification system containing the tetranucleotide STR loci: HUMVWFA31/A, HUMTH01, D20S85, D8S1179, HUMFIBRA, D21S11, and D18S51, in conjunction with the amelogenin sex test, in addition to a modified system omitting the locus D20S85. Polymerase chain reaction (PCR) products were fluorescently detected on an automated sequencer and automatically sized against an internal size standard by Genescan software. Both systems were routinely able to type 500 pg of undegraded DNA. At DNA concentrations between 50-500 pg, partial profiles were produced, but no allelic drop-out was observed. Balanced amplification of all loci occurred over a wide range of DNA concentrations from 50 pg to 10 ng. Alteration of reagent concentrations and cycling parameters from optimal resulted in variation in the efficiency of individual locus amplification relative to the other loci within the system. This was also observed at high ionic strength or extreme pH. However, at all reagent concentrations and conditions, allelic drop-out was not observed. These multiplex systems have potential in both routine forensic and intelligence database applications.

Buffers↗

Validation of the Applied Biosystems Prism 377 automated sequencer for the forensic short tandem repeat analysis.

The Applied Biosystems (ABI) Prism 377 DNA sequencer has been evaluated in an attempt to increase the throughput of samples for short tandem repeat (STR) analysis, in both forensic casework and the UK National Criminal Intelligence DNA Database. The gel system assessed consisted of 0.2 mm, 4% acrylamide 6 M urea gels, with a well-to-read distance of 36 cm. Gels were run at a constant voltage of 3 kV and constant temperature of 51 degrees C. The run time of our second generation multiplex (SGM) STR system was achieved in less than 2 h. Rigorous validation has been performed on the instrument hardware and software. Complete resolution of 1 base differences was obtained, up to and beyond 350 bases; sizing precision across gels was more than 2-fold higher than the 373A and the sensitivity was increased by one third.

Autoanalysis↗