PubMed Health⌕ Search

Biomedical subjects

R R Steuer

Publications and source records attributed to R R Steuer.

10 recordsLinked to original sources

Noninvasive transcutaneous determination of access blood flow rate.

BACKGROUND: Current indicator dilution techniques for determining the vascular access blood flow rate (Qa) require reversal of the dialysis blood lines and are time consuming. We have recently described an indicator dilution technique for determining Qa using a novel optical transcutaneous hematocrit (Hct) sensor that does not require reversal of the dialysis lines, and have validated the accuracy of this method (TQa) in vitro. METHODS: This study compared results using the TQa method with those obtained using a similar indicator dilution technique but which required reversal of the dialysis lines (HD01 Monitor, Transonic Systems, Ithaca, NY, USA) during routine hemodialysis in 59 patients (25 native fistulas and 34 synthetic grafts). The sensor for the TQa method was placed on the skin directly over the access to measure changes in Hct approximately 25 mm downstream of the venous needle. A single 30 mL bolus of saline was infused into the dialyzer venous line over approximately six seconds without reversal of the dialysis blood lines, and the vascular access flow rate was calculated using indicator dilution methods from the time-dependent decrease in the Hct downstream of the venous needle. Two additional small-scale studies were performed to assess the effect skin pigmentation and to evaluate further the reproducibility of the TQa method. RESULTS: Qa values determined by the TQa method were highly correlated with those determined by the HD01 method (N = 72, R2 = 0.948, P < 0.001) over the range of 153 to 2,042 mL/min. There was no significant difference between vascular access flow rates determined by the TQa method and those determined by the HD01 METHOD: Results from one small-scale study showed that the relationship between Qa values determined by the TQa and the HD01 methods was similar when tested only among black patients (N = 12), suggesting that skin pigmentation is not an important determinant of the accuracy of the TQa METHOD: The second small-scale study showed that the intratreatment coefficient of variation for the TQa method was 7.8 +/- 5.6% (N = 14). CONCLUSIONS: : These results show that transcutaneous measurement of Qa is an accurate, simple, and fast technique for determining Qa without requiring the reversal of the dialysis blood lines.

Aged↗

Optical measurement of hematocrit and other biological constituents in renal therapy.

Optical sensors have advanced significantly over the past 2 decades leading to today's noninvasive optical measurement capabilities and their widespread applications in renal therapy. These measurements provide significant advantages to the clinician. For example, a given blood constituent can be monitored in real time (continuously, nondestructively), which facilitates the ability to optimally "titrate" the therapy with immediate visual feedback. Optical methods have another intrinsic advantage in that each biologic constituent has its own unique spectral "signature" allowing for simultaneous, multiple, and specific measurements of biologic analytes. Use of this budding spectral technology in renal therapy today provides for increased patient safety (by measuring plasma-free hemoglobin, microemboli, clots, oxygen saturation, blood leaks, and hematocrit), measurements of dialysis dose (dialysate urea levels), dry weight (tissue water monitoring), access viability (recirculation, access blood flow), cardiac status (absolute blood volume, cardiac output), and enhanced continuous fluid management (fluid overload, critical blood volume). As microelectronics and signal processing capabilities continue to advance, so will the future of optical diagnosis and treatment. These capabilities translate directly to improved patient quality of life.

Hematocrit↗

Peripheral donor leukocytes prolong survival of rat renal allografts.

BACKGROUND: The development of strategies to enhance the survival of transplanted organs and to potentially lower or even discontinue immunosuppressive therapy would represent a significant advancement in post-transplant patient care. METHODS: We studied the effect of pretransplant infusion of donor leukocytes alone or in combination with a short course of cyclosporine on the long-term outcome of a rat model of kidney allograft. RESULTS: A single intravenous infusion of donor peripheral blood leukocytes (100x10(6) cells) from Brown-Norway (BN) rats into major histocompatibility complex (MHC) incompatible Lewis recipients largely failed to prolong kidney allograft viability from the same donor transplanted 60, 40, or 30 days after cell infusion. A short course of cyclosporine (per se, unable to prolong graft survival) was started at the same day of donor leukocyte infusion, but instead was able to prolong the survival of the BN kidney transplant-performed 40 days later-but not of a Wistar Furth (WF) third party, with some animals even developing tolerance. A mixed lymphocyte reaction of host cells from long-term surviving rats to BN stimulator cells was significantly reduced as compared with controls. Donor BN DNA was detected in the peripheral blood of Lewis rats until day 40 after BN leukocyte infusion. Microchimerism persisted (60 to 70 days post-transplant) in most long-term graft recipients. Reducing the time interval between donor leukocyte infusion and subsequent kidney transplant to 10 days still prolonged graft survival. Donor peripheral blood mononuclear cells, but not polymorphonuclear cells, in the leukocyte preparation contributed to prolong kidney allograft survival. CONCLUSIONS: Pretransplant donor leukocyte infusion under the appropriate conditions can tip the immune balance toward improved graft acceptance. This result could be relevant to the achievement of donor-specific tolerance of the graft with the maintenance of an intact response to third-party antigens.

Animals↗

Enhanced fluid removal guided by blood volume monitoring during chronic hemodialysis.

Fluid overload predisposes chronic hemodialysis patients to cardiovascular disease, a significant cause of morbidity and mortality in these patients. We evaluated the efficacy of monitoring changes in blood volume during routine hemodialysis to detect fluid overload. Intradialytic changes in blood volume were monitored by continuously measuring hematocrit in all 56 patients in a single dialysis unit over 7 weeks. After Week 1, patients were categorized into 2 separate groups depending on their maximum intradialytic decreases in blood volume. In Group 1, 46 of 56 or 82% had greater than a 5% decrease in blood volume while in Group 2, 10 of 56 or 18% had less than a 5% decrease in blood volume. During Weeks 2-7, dialytic fluid removal was intentionally increased in Group 2 patients by 0.80 +/- 0.62 L (mean +/- SD) or 47 +/- 43%. This intervention resulted in a larger (p < 0.02) intradialytic decrease in body weight (2.7 +/- 0.9 kg versus 2.0 +/- 0.8 kg) and a larger (p < 0.02) intradialytic decrease in blood volume (15 +/- 5% versus 4 +/- 1%) than experienced during Week 1 with a low incidence of symptoms. We conclude that there is a significant percentage of chronic hemodialysis patients who can tolerate additional fluid removal without hypovolemic symptoms even though they are considered to be at dry weight by routine physical examination and that the identification of these patients can be facilitated by intradialytic blood volume monitoring.

Blood Volume↗

Reducing symptoms during hemodialysis by continuously monitoring the hematocrit.

Previous studies have demonstrated that patients on hemodialysis develop intradialytic symptoms when the blood volume decreases to a critical level. Using a continuous monitor (CRIT-LINE; In-Line Diagnostics, Riverdale, UT) to determine the instantaneous hematocrit and blood volume, we observed that certain intradialytic symptoms occurred at a patient-specific hematocrit. In the present study, we exploited this hematocrit threshold concept to decrease the occurrence of lightheadedness, cramping, and nausea, regardless of blood pressure changes. In the first phase of the study, hematocrit threshold was established in six hypotension-prone patients. Five patients entered into the second phase in which ultrafiltration rates were increased 25 percent above prescribed values at the beginning of the experimental sessions. Subsequently during the experimental sessions, ultrafiltration rates were manipulated to maintain the instantaneous hematocrit value 2 units below the established hematocrit threshold. Sessions without ultrafiltration rate adjustments based on hematocrit served as controls. There were no differences between experimental (n = 27) and control (n = 28) sessions with respect to treatment time (230 minutes v 229 minutes), fluid volume removed (3,351 mL v 3,383 mL), and maximum percentage change in systemic blood pressure (-26 percent v -24 percent). However, there were less symptoms during the experimental sessions (26 percent v 57 percent; P = 0.038). These data suggest that a twofold reduction in intradialytic symptoms can be achieved using continuous hematocrit monitoring without altering treatment times or volume removed in hypotension-prone patients.

Blood Volume↗

Determination of circulating blood volume by continuously monitoring hematocrit during hemodialysis.

Dialysis-induced hypovolemia occurs because the rate of extracorporeal ultrafiltration exceeds the rate of refilling of the blood compartment. The purpose of this study was to evaluate a method for calculating circulating blood volume (BV) during hemodialysis (HD) from changes in hematocrit (Hct) shortly (2 to 10 min) before and after ultrafiltration (UF) was abruptly stopped. Hct was monitored continuously during 93 HD treatment sessions in 16 patients by an optical technique and at selected times by centrifugation of blood samples. Total plasma protein and albumin concentrations were also measured at selected times. Continuously monitored Hct correlated with Hct determined by centrifugation (R = 0.89, N = 579). Relative changes in BV determined by continuously monitored Hct were not different from those determined by total plasma protein concentration (P = 0.05; N = 273). Calculated BV at the start of dialysis (4.1 +/- 1.3 L) was not different (P = 0.18, N = 12) from that derived anthropometrically from the patient's dry weight (4.6 +/- 0.8 L), and calculated BV when UF was stopped was 3.2 +/- 0.5 L (46 +/- 7 ml/kg body wt). These latter estimates of BV are consistent with those determined previously by dilution techniques in HD patients. It was concluded that (1) relative changes in BV assessed by continuously monitored Hct were unbiased and (2) BV can be determined noninvasively during HD by continuously monitoring Hct and temporarily stopping UF.

Blood Volume↗

Hematocrit as an indicator of blood volume and a predictor of intradialytic morbid events.

Hematocrit (H) levels can change during hemodialysis, and these changes in H are inversely related to changes in blood volume (BV). The objectives of this study were to determine whether mean arterial pressure (MAP) decreases with decreasing BV and rising H during hemodialysis, and to determine the relationship between dialysis induced intravascular volume depletion and intradialytic morbid events (IME), defined as hypotension, cramping, or lightheadedness that led to dialysis staff intervention. We monitored H continuously using a noninvasive optical technique in 93 hemodialysis sessions in 16 patients. IME occurred in 48 sessions. MAP decreased with increasing H in 10 of 16 patients (P < 0.05), but the relationship between MAP and H varied among the patients. The rate of BV change during sessions without morbidity (5.6 +/- 3.6 [SD] %/hr) was lower (P < 0.001) than that preceding IME in the other sessions (12.2 +/- 5.5 [SD] %/hr). Twelve of 16 patients who exhibited recurrent IME during this study experienced these events when H reached a patient specific threshold. It is concluded that MAP decreases with decreasing BV and increasing H in many patients on hemodialysis, and that a high rate of BV change often indicates that IME are forthcoming. It is further hypothesized that a patient specific H threshold is indicative of a critical BV level below which certain patients experience IME.

Blood Pressure↗