PubMed Health⌕ Search

Biomedical subjects

R Rabinovitz

Publications and source records attributed to R Rabinovitz.

9 recordsLinked to original sources

A simplified ingestion procedure for esophageal capsule endoscopy: initial evaluation in healthy volunteers.

BACKGROUND AND STUDY AIMS: Initial studies on esophageal capsule endoscopy (PillCam ESO) reported excellent sensitivity and specificity, but these were followed by mixed results in several subsequent studies, probably due to deviations from the recommended ingestion protocol and the inconvenience of capsule ingestion in the supine position. The aim of this study was therefore to test a simplified ingestion procedure (SIP) for PillCam ESO. PATIENTS AND METHODS: Using a cross-over study design, the SIP was prospectively compared with the original ingestion procedure for PillCam ESO in 24 healthy volunteers (15 men, nine women; mean age 44, range 27 - 70) and evaluated for: bubbles/saliva interference at the Z-line, Z-line circumferential visualization (quadrants), and convenience and ease of the ingestion procedure. All Rapid 4 videos were reviewed in a randomized manner and read by an experienced PillCam ESO reader blinded to the ingestion procedure used. RESULTS: It was found that the SIP significantly improved visualization in comparison with the original ingestion procedure, with less interference due to bubbles/saliva observed at the gastroesophageal junction ( P = 0.002) and improved visualization of the Z-line ( P = 0.025). Although the esophageal transit time was significantly faster with the SIP (3 : 45 min vs. 0 : 38 min; P = 0.0001), there were no differences in the number of Z-line frames/images captured. CONCLUSIONS: This new, simplified ingestion procedure for PillCam ESO provides significantly improved visualization of the Z-line in healthy volunteers. The overall test characteristics of PillCam ESO using SIP should be tested in patients with esophageal disease.

Adult↗

Measurement of cardiac function in conscious rats.

The goal of this study was to establish that 1. blood velocity profile in the rat aorta is parabolic, and 2. measure of left ventricular thickening fraction can be used in rats. Spontaneously hypertensive and normotensive Wistar Kyoto rats were instrumented with a 20-MHz pulsed Doppler flow probe around the thoracic aorta and a 20-MHz pulsed Doppler thickening probe on the left ventricle. Doppler frequency shifts were measured throughout the entire aorta diameter, and individual blood velocity profiles were constructed. It was demonstrated that blood velocity in the ascending aorta of rats is laminar; therefore, cardiac output can be measured using the pulsed Doppler method. In Wistar Kyoto rats, left ventricular thickening fraction was 24 +/- 1% and 25 +/- 1%, 2 and 3 weeks following surgery. In spontaneously hypertensive rats, left ventricular thickening fraction was 22 +/- 2%. Halothane depressed left ventricular thickening fraction, whereas isoproterenol increased left ventricular thickening fraction in conscious rats. Thus, pulsed Doppler technique is a valuable tool for evaluating cardiovascular function in conscious rats.

Analysis of Variance↗

Endometrial laser intrauterine thermotherapy: the first series of 100 patients observed for 1 year.

OBJECTIVE: To describe a new instrument (GyneLase) that offers a new approach (endometrial laser intrauterine thermal therapy [ELITT]) to treatment of menorrhagia and to evaluate the efficacy of ELITT in the management of dysfunctional uterine bleeding. DESIGN: Prospective study. SETTING: University hospital. PATIENT(S): 100 premenopausal women with dysfunctional uterine bleeding were observed for 1 year. INTERVENTION(S): Intrauterine laser thermotherapy with a diode laser. MAIN OUTCOME MEASUREMENT(S): Amenorrhea rate after 1 year. RESULT(S): The amenorrhea rate after 1 year of follow-up was 71%, and the rate of amenorrhea/severe hypomenorrhea rate was >90%; these rates are much higher than those in the literature after such procedures as electrosurgery or intrauterine thermal balloon therapy. The ELITT procedure is an inherently safe and simple alternative, providing controlled and effective treatment of the entire endometrium. In contrast to traditional endometrial ablation using a neodymium yttrium-aluminum-garnet laser, the ELITT procedure does not require intensive training or hysteroscopic control; it is also far less risky, because the power used per unit area is 1,000 times lower. CONCLUSION(S): The ELITT procedure is a new nonhysteroscopic technique for endometrial ablation. The technique is very safe and offers the highest amenorrhea rate to date in the literature.

Adult↗

Parental attitudes toward obstetric ultrasound examination.

OBJECTIVE: The aim of the study was to assess the effect of ultrasound examination on parental attitudes and anxieties. MATERIAL AND METHOD: Ultrasound examinations were carried out on 1,089 pregnant women with uncomplicated pregnancies at a mean gestational age of 20.9 weeks (minimum 10 weeks). Before and after the ultrasound examination, patients completed a questionnaire comprising 26 five-point numerical scales relating to anxiety levels, and difference scores for pre- and post-scan levels of fears and anxieties were computed. RESULTS: We showed that the reduction of anxiety following ultrasound examination was inversely related to gestational age, but was unrelated to demographic or medical variables, such as the risk level at the time of the scan. Similarly, anxiety was not reduced because of the presence of the spouse, although the spouse's presence did significantly increase inter-partner bonding. CONCLUSION: This study showed that "routine" ultrasound scan may have significant psychological effects on parental attitudes toward each other and the fetus.

Adolescent↗

Ultrasonographic "endometrial three-layer" pattern: a unique finding in ectopic pregnancy.

Although diagnostic ultrasonography is playing an increasing role in the investigation of the patient with suspected ectopic pregnancy (EP), it has significant limitations in the very early stages of pregnancy. By sonographically exploring the intrauterine echoes in 45 cases of documented EP, we demonstrated a unique pattern in 28 cases (62.2%). A well-defined spheric structure forming an endometrial three-layer (ETL) pattern was seen, probably formed by a midline echo between the two adjacent edematous proliferative layers of the endometrium, the latter resembling the late proliferative endometrium. In 17 patients with a proved EP (37.8%), the ETL pattern was not demonstrated. However, the ETL was not demonstrated in all 40 cases of early intrauterine pregnancy and all 50 cases of miscarriage. These findings suggest a 100% specificity and a sensitivity of 62.2% for the ETL pattern in the diagnosis of EP.

Endometrium↗

An experimental study of pressure losses in pulsatile flows through rigid and pulsating stenosis.

The time-dependent pressure curves of a pulsatile flow across rigid and pulsating stenoses were investigated experimentally in a laboratory simulator of the outflow tract of the heart right ventricle. The experiments were performed within the range of physiological conditions of frequency and flow rate. The experimental setup consisted of a closed flow system which was operated by a pulsatile pump, and a test chamber which enabled checking different modes of stenosis. Rigid constrictions were simulated by means of axisymmetric blunt-ended annular plugs with moderate-to-severe area reductions. The pulsating stenosis consisted of a short starling resistor device operated by a pulsating external pressure which was synchronized by the pulsatile flow. It was found that the shape of the time-dependent pressure curve upstream of the stenosis was different in the case of rigid stenosis than in the pulsating one. Potential clinical applications of the work may relate to diagnosis of the type of stenosis in the congenital heart disease known as Tetralogy of Fallot.

Biomechanical Phenomena↗