PubMed HealthSearch

Biomedical subjects

R Rambaldi

Publications and source records attributed to R Rambaldi.

9 recordsLinked to original sources

Does placebo lower blood pressure in hypertensive patients? A noninvasive chronobiological study.

Placebo controlled trials have generally been used in order to evaluate the antihypertensive efficacy of drugs. There is some evidence, though, that blood pressure might not be influenced by placebo. Non-invasive devices for automatic blood pressure monitoring are likely to provide a better assessment of blood pressure response to drugs, as well as to different physiologic and pathologic conditions, than the traditional sphygmomanometric devices. The aim of this study was to investigate the effect of placebo on blood pressure recorded automatically and non-invasively. For this purpose, a chronobiologic approach to the collection, evaluation and interpretation of data seemed most appropriate. A group of 12 patients with a clinical diagnosis of essential hypertension underwent automatic blood pressure monitoring in hospital for 4 days. Measurements were taken every 15 min by an oscillometric instrument with an automatically inflated cuff. After a washout period during which the patients received no treatment, pressure recording was undertaken under basal conditions for 2 days. On the third and fourth days of study, the patients received 2 tablets of placebo, one at 10 a.m. and one at 10 p.m. In each patient a highly significant circadian rhythm was documented for systolic and diastolic pressure, both under basal conditions and during placebo administration. Blood pressure mesors were higher than reference standards and were not significantly affected by placebo. The circadian amplitudes and acrophases did not differ significantly before and during placebo. Our data indicate that automatically recorded blood pressure is not influenced by placebo.

Adult

Slow-release nifedipine: effect on the circadian rhythm of blood pressure in essential hypertension.

The aim of this study was to investigate the effect of orally administered, slow-release, nifedipine tablets on the circadian rhythm of blood pressure and heart rate, in hospital patients with clinical diagnosis of hypertension validated by a chronobiologic inferential statistic method. A group of 14 patients (nine women and five men, 47 to 71 years old) with clinical diagnosis of "essential hypertension" underwent automatic blood pressure and heart rate monitoring in a hospital room for 48 hours. Measurements were taken every 15 min by an oscillometric instrument with automatically inflated cuff. The patients received no treatment during the two proceeding weeks and the first day of the study. On the second day, slow-release nifedipine tablets were administered, one at 10 a.m. and one at 10 p.m. A highly significant circadian rhythm was documented for systolic and diastolic blood pressure, mean arterial pressure and heart rate, both in basal conditions and after nifedipine. Blood pressure mesors were higher than reference standards in basal conditions, and were lowered (average decrease = 20 mmHg for systolic and 9 mmHg for diastolic mesor) by nifedipine. A significant, though minor, elevation of heart rate mesor (from 70 to 75 b.p.m.) was also noted during treatment. The circadian amplitudes of blood pressure and heart rate did not differ significantly before and during treatment. In conclusion, the circadian rhythm of blood pressure is still present with the same amplitude after slow-release nifedipine, but is set at a lower pressure level. Heart rate rhythm is also preserved, with only a minor elevation of its mesor.

Administration, Oral

[Allergic contact dermatitis: the evaluation of positivity in skin tests in the workers of an animal feed plant].

Patch tests were performed on 43 workers employed in an animal fodder plant, a typical dust-laden environment. The aim of the study was to establish and assess the incidence of preclinical sensitization to the substances used, some of which are well known allergens, and identify which of these were mostly responsible. On the whole, the tests did not reveal any major reaction to the allergens used, nor polysensitization. However, an unexpected number of cases was sensitized to phenothiazine, a substance that had not been use for the preceding two years. This observation is of interest since phenothiazine is scarcely allergenic and skin eruptions occur only after photosensitization.

Adult

[Acromial bone].

Explore the source record for details and available documents.

Adolescent