Organ doses, detriment and genetic risk from interventional vascular procedures in Málaga (Spain).

Nowadays, the radiological risk from simple X-ray procedures is well known. The purpose of this work has been to estimate the population risk from digital angiographic and interventional procedures and to compare it with the one from simple procedures in the same population. The population risk has been estimated according to the following quantities: genetically significant dose, somatic significant dose, collective effective dose, annual per caput effective dose and detriment. These have been estimated from dose area product and organ dose. Organ dose values were estimated with the Eff-Dose software. A population of 605410 people were included in the study. In 1996, 1312 patients were to digital interventional vascular procedures in Malaga, and 159 of them were selected in this research project to obtain the dose area product and organ dose. The results obtained for the quantities evaluated are: genetically significant dose, 4.1 microGy; somatic significant dose, 0.9 mSv; collective effective dose, 11.65 person-Sv: annual per caput effective dose, 0.02 mSv and detriment, 0.65 radiogenic cancers per year. These procedures supply a high radiation dose, so they should have a greater contribution to population dose and risk than simple examinations. However, our results indicate just the opposite.

Adolescent↗

Stochastic risk estimate for barium radiological examinations in Malaga (Spain).

The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Señora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective dose, annual effective dose 'per capita' and detriment, which are useful for assessing the population risk of cancer or hereditary effects after x-ray exposure. The contribution to the genetically significant dose is 6.7 microGy, to the somatically significant dose 8.82 mSv-yr, 16.07 person-Sv for the collective effective dose, 0.03 mSv for the 'per capita' annual effective dose and the annual aggregated detriment is 0.33.

Age Factors↗

Patient dose from barium procedures.

The objective of this work was to estimate patient doses (dose-area product, organ dose, effective dose and entrance surface dose) for barium procedures. A total of 175 procedures, in 175 patients, for five different examination categories was analysed. Dose-area product was determined using a transmission ionization chamber. Organ dose and effective dose were assessed using a knowledge of the examination and the software. For all patients, the contribution of fluoroscopy to the total dose was greater than that from radiography. Dose-area product from double contrast barium enema, enteroclysis and intestinal tract procedures was higher than that obtained for the other procedures. The average effective dose was 1.04 mSv and 13.99 mSv for oesophageal tract and enteroclysis examinations, respectively. Entrance surface dose in the oesophageal tract was 16 mGy, 10 times lower than for the other four procedures. Patient dose reduction in barium procedures may be achieved by improved training of resident radiologists, senior radiologists and other specialists in radiation protection.

Adult↗

Patient dose in radiologically guided interventional vascular procedures: conventional versus digital systems.

PURPOSE: To calculate the difference in the patient radiation dose in radiologically guided interventional vascular procedures between conventional and digital systems and to estimate the effective dose and the energy imparted with the digital system. MATERIALS AND METHODS: A total of 318 procedures (in 318 patients) in 15 different examination groups were analyzed. The dose-area product was determined by using a transmission chamber fitted to an x-ray-tube light-beam diaphragm; the effective dose was determined by using software. RESULTS: Urinary and biliary tract procedures showed small differences in the average dose-area product between conventional and digital systems. The dose-area products in the vascular procedures were higher with the digital than with the conventional system. The average effective dose and energy imparted were 0.88 mSv and 129 mJ, respectively, in the subcutaneous placement of a reservoir for analgesic administration and as much as 25.7 mSv and 829 mJ, respectively, in spermatic vein embolization. CONCLUSION: The dose-area product was higher with the digital system than with the conventional system in 13 of the 15 groups. To reduce the patient dose in vascular interventional radiology procedures, the training of personnel and the frequent use of conventional fluoroscopy and low-dose imaging are required.

Adult↗