Phasic three-dimensional impedance imaging of cardiac activity.

Electrical impedance images were made using the ACT 3 instrument, which applies currents simultaneously to 32 electrodes and measures the resulting voltages on those same electrodes. A reconstruction algorithm was written for a three-dimensional cylinder having electrodes in two or four layers, using current patterns that pass current among different planes of electrodes, as well as within each plane. We have previously reported useful vertical resolution by the use of added layers of electrodes. The aim of the present study was to demonstrate that physiologically useful information can be obtained by examining cephalo-caudal differences in three-dimensional images. Phasic changes throughout the cardiac cycle are seen to be markedly different at the heart compared to lung region, both above and beside it. We formed hydrogel electrodes each 3 cm tall and 7 cm wide and applied them to the thorax of an upright human subject in four horizontal rows; each row contained eight electrodes. During breath-holding, cardiac activity was seen in all layers. With systole, conductivity in the anterior of the lowest layers decreased, but not in the upper layer. In the upper layers, conductivity increased with systole in many regions. These observations are consistent with the opposite changes in blood volume of the heart and lungs and the locations of these organs. This paper demonstrates the feasibility of producing and displaying physiologically interpretable three-dimensional images of the chest in real time.

Adult↗

Real-time three-dimensional electrical impedance imaging.

Electrical impedance tomography is a technology for producing images of internal body structures based upon electrical measurements made from electrodes on the body surface. Typically a single plane of electrodes is used, seeking to reconstruct a cross section of the body. Yet the majority of image reconstruction algorithms ignore the three-dimensional (3D) characteristics of the current flow in the body. Actually, a substantial amount of current flows out of the electrode plane, creating distortions in the resulting images. This paper describes a reconstruction algorithm, ToDLeR, for solving a linearized 3D inverse problem in impedance imaging. The algorithm models the body as a homogeneous cylinder and accounts for the 3D current flow in the body by analytically solving for the current flow from one or more layers of electrodes on the surface of the cylinder. The algorithm was implemented on the ACT3 real-time imaging system and data were collected from a 3D test phantom using one, two and four layers of electrodes. By using multiple planes of electrodes, improved accuracy in any particular electrode plane was obtained, with decreased sensitivity to out-of-plane objects. A cylindrical target located vertically more than 8 cm below a single layer of 16 electrodes, and positioned radially midway between the centre and the boundary, produced an image that had 35% of the value obtained when the target was in the electrode plane. By adding an additional layer of 16 electrodes below the first electrode plane, and using 3D current patterns, this artefact was reduced to less than 10% of the peak value. We conclude that the 3D algorithm, used with multiple planes of electrodes, reduces the distortions from out-of-plane structures in the body.

Algorithms↗

Effect of electrode size on impedance images of two- and three-dimensional objects.

The sensitivity of an impedance imaging system to small cylindrical inhomogeneities in two-dimensional (2-D) and three-dimensional (3-D) saline tanks was studied for different height electrodes and different height targets. Experimental results were compared with analytical models. Inhomogeneities in the 3-D tank having limited vertical extent were detected by electrodes of vertical size comparable to that of the inhomogeneity. Taller electrodes had increased sensitivity to short targets to only a limited extent. When the electrode height was more than twice that of the target, sensitivity decreased or remained the same with further increases in electrode height. The system was less sensitive to inhomogeneities in the 3-D tank than to those in the 2-D tank. The distinguishability of conductors was greater than that of insulators in the 3-D tank, and the opposite was true in the 2-D tank, consistent with an analytical result.

Agar↗