PubMed Health⌕ Search

Biomedical subjects

R S Miyahira

Publications and source records attributed to R S Miyahira.

3 recordsLinked to original sources

Computerized surveillance of errors in newborn screening practice.

We describe the use and early results of the Oregon Public Health Laboratory computer to monitor hospital and practitioner compliance with state newborn screening recommendations. The system tracks five major categories of screening practice in which 21 types of errors affecting screening test quality have been identified. Our initial pilot study examined computer generated data for 23,717 specimens submitted by 116 Oregon birthing facilities over a four-month period. Results show that 58.3 per cent of newborn screening specimens were submitted incorrectly according to current state recommendations.

Diagnostic Errors↗

Detection of congenital hypopituitary hypothyroidism: ten-year experience in the Northwest Regional Screening Program.

We examined the results of the Northwest Regional Screening Program (NWRSP) over its first 10 years to determine whether the detection of hypopituitary hypothyroidism is a justified advantage of the primary thyroxine (T4)-supplemental thyroid-stimulating hormone (TSH) screening strategy, and to determine whether all such infants will be detected by this screening approach. Between May 1975 and May 1985, the NWRSP screened 850,431 infants, detecting 192 infants with primary hypothyroidism (1:4429) and eight with hypopituitary hypothyroidism (1:106,304). In 11 additional infants, TSH deficiency, not detected by the screening program, was diagnosed on recognition of clinical features over the same period. Thyroid hormone treatment was begun in seven of the 11 infants prior to obtaining the screening sample results because of clinical symptoms of hypopituitarism, including hypoglycemia, persistent jaundice, microgenitalia, diabetes insipidus, midface hypoplasia, cleft lip or palate, or abnormalities of vision. The other four infants were not detected despite clinical features of hypopituitarism (in retrospect) and low serum T4 with TSH concentration below assay sensitivity on at least one screening sample. The most accurate assessment of total cases comes from Oregon, where all cases of congenital hypopituitarism are referred to our center; we estimate a frequency of 1:29,000. In our experience, a combination of newborn T4-supplemental TSH screening measurements and recognition of clinical features of hypopituitarism is the optimal strategy for detecting infants with congenital hypopituitary hypothyroidism.

Congenital Hypothyroidism↗

Screening for congenital hypothyroidism with specimen collection at two time periods: results of the Northwest Regional Screening Program.

To determine the benefit of collecting two routine specimens to test for congenital hypothyroidism, we examined the results of our newborn screening program during the last 9.5 years. The Northwest Regional Screening Program (NWRSP) performs a primary thyroxine test with thyroid-stimulating hormone determinations on the lowest 10% of dried blood filter paper specimens. An initial specimen is obtained in the newborn period, and a routine second specimen is collected at approximately 4 to 6 weeks of age in all infants born in Oregon and 25% of infants born in Idaho, Montana, Alaska, and Nevada. Between May 1975 and October 1984, 182 infants with primary hypothyroidism were detected from 811,917 infants screened, a prevalence rate of 1:4,461. The routine second specimen led to the diagnosis of 19 infants of 484,604 infants screened, a detection rate of 1:25,505. When infants detected by the second screen were compared with those detected by the first screen, they had higher thyroxine and lower thyroid-stimulating hormone concentrations on filter paper and serum specimens. When thyroid scanning was used, all but one infant detected by the second screen had some residual thyroid tissue, whereas 35% of infants detected by the first screen had thyroid aplasia. Skeletal maturation was more likely to be normal in infants detected by the second screen. These infants appear to have milder hypothyroidism due to a later age of onset or slower evolution of thyroid failure. At a cost of $31,881 per infant detected by the second screen, the NWRSP found it cost-effective to obtain a routine second specimen.

Congenital Hypothyroidism↗