PubMed Health⌕ Search

Biomedical subjects

R S Skeen

Publications and source records attributed to R S Skeen.

7 recordsLinked to original sources

Intrinsic bioremediation: an environmental restoration technology.

In the past year, there has been a dramatic maturation of intrinsic bioremediation technologies. As methods pertinent to the intrinsic bioremediation of fuel hydrocarbons have become better established, a comprehensive protocol has been developed for the validation and prediction of these processes. Study of intrinsic bioremediation of other prevalent contaminants, such as chlorinated aliphatics, polychlorinated biphenyls, and high explosives, has also been undertaken.

Biodegradation, Environmental↗

Application of compiled BASIC in developing software for collection and analysis of neuronal firing frequency data.

Two programs are described which use an IBM-AT compatible personal computer, equipped with an analog-to-digital converter, to collect and analyze electrophysiological data. The first program is used to determine neuron firing rates during intracellular experiments and to save these results on disk. The second program is used to perform off-line analysis of the frequency data. Both programs are written entirely in the well known BASIC language and the Microsoft QuickBASIC compiler is employed for their use. All of the necessary hardware can be purchased commercially. In this paper emphasis is placed on the strategies and limitations involved when this high-level language is applied to tasks often needed in data acquisition and analysis. Both on- and off-line collection schemes are considered. This software is available from the authors.

Animals↗

Effects of temperature and analyte application technique on neuron-based chemical sensing.

Results are presented which enhance the field of neuron-based sensing by providing insight on the effects of operating temperature and analyte application technique (pulse versus back-mixed) on sensing properties. In these studies, serotonin sensing attributes of giant visceral neurons VV1 and VV2 from the pond snail Lymnea stagnalis were measured. Experiments using a rapid fluid-exchange system reveal a concentration-dependent increase in maximum firing frequency similar to that reported earlier for a slow well-mixed application. With a rapid application, however, the maximum firing frequency is reached more quickly, and there is less cell-to-cell variability in both the maximum response and sensitivity. Given an application technique, an increase in temperature causes an increase in sensitivity and maximum firing frequency, as well as a decrease in the time required for the response to return to baseline following removal of the analyte. To provide insights on the kinetics of the serotonin-induced response, the effects of temperature and concentration on the rates of activation, recovery and desensitization were examined in detail. In general, it was found that an increase in temperature increases the rates of activation and desensitization, while the effects on recovery were not apparent. In addition, both the rates of activation and desensitization have a direct dependence on concentration while the rate of recovery has an inverse dependence.

Action Potentials↗

Optimization of glass microelectrode properties by response surface methodology.

Glass microelectrodes filled with electrolyte solutions are standard tools for electrophysiological studies. However, for any given application, there are limitations to the properties of the microelectrode, such as impedance and shank length, that can yield satisfactory results. The trial and error approach in pulling electrodes with the desired properties can be time consuming. The use of a response surface procedure which allows the experimenter to change more than one factor at a time and therefore determine the desired puller condition more efficiently is demonstrated. Also, design improvements for the World Precision Instrument, Model PUL-1, Microelectrode puller, used in this study are suggested.

Animals↗

Evaluation of neuron-based sensing with the neurotransmitter serotonin.

Results are presented on the development of a novel biosensor which will use neurons or neuronal components as both the recognition elements and primary transducers for analyte quantitation. This concept is demonstrated and evaluated by exposing identified neurons from the visceral ganglia of the pond snail Limnea stagnalis to the model analyte serotonin. Experiments reveal a reversible, concentration-dependent increase in the rate of spontaneous action potential generation, over a concentration range of four orders of magnitude. Studies with the antagonist methysergide verify that this response is mediated through serotonin-sensitive receptors. Exposure of the neurons to serotonin causes the firing frequency to rapidly increase to a maximum and then slowly diminish to a sub-optimal level. It was found that the maximum frequency provides an indication of chemical concentration that is repeatable. Data are also presented which further advance the field of neuronal biosensing by demonstrating both the effects of cell to cell variability on response reproducibility and the effects of the desensitizing response on the operation of a neuron-based sensor in both a continuous and discontinuous mode.

Action Potentials↗