[Thrombus attached to a Sideris septal occluder system 6 years later].

HISTORY AND CLINICAL FINDINGS: A 61-year-old man was admitted to hospital because of right-sided hypaesthesia. Additionally he reported a brief speech disturbance some weeks before. Neurological examination indicated right-sided sensomotoric hemiparesis and left-sided upper quadrant anopia. 6 years ago recurrent transient ischaemic attacks (TIA) was diagnosed caused by paradoxical embolism through a persistent foramen ovale (PFO). The PFO was closed with a 45 mm Sideris button occluder device. After this, he reported no symptoms of cerebral ischaemia and he did not take any antiplatelet therapy. INVESTIGATIONS: Transesophageal echocardiography (TEE) showed a left atrial thrombus attached to the occluder. Cerebral computed tomography revealed infarction in regions supplied by the right posterior cerebral artery and left media cerebral artery. As additional risk factor for thrombosis a heterozygous factor V Leiden mutation was diagnosed. DIAGNOSIS: Multiple cerebral infarctions caused by a thrombus attached to an occluder system 6 years after interventional closure of persistent foramen ovale in a patient with heterozygous factor V Leiden mutation. TREATMENT AND COURSE: The patient was anticoagulated (phenprocoumon) and the thrombus gradually dissolved. CONCLUSION: A thrombosis on a Sideris occluder device may cause cerebral infarctions even years after transcatheter closure of a PFO.

Anticoagulants↗

Patent foramen ovale closure in patients with transient ischemia attack/stroke.

Paradoxical embolism through a patent foramen ovale (PFO) has been recognized as a potential cause of transient ischemia attack (TIA) and stroke especially in younger patients. The therapeutic options are medical treatment (antiaggregation or anticoagulation) with an annual recurrence rate of 3% to 4% for stroke or TIA, surgical PFO closure, or catheter closure. Randomized studies are ongoing; however, the results will not be available soon. Since August 1994, we have attempted catheter closure of a PFO in 281 patients (age 17 to 79 years, mean 46.8 +/- 13.2) with paradoxical embolism. Of these, 184 patients had at least one embolic stroke, 112 patients at least one TIA, and 15 patients at least one peripheral embolism. The diameter of the PFO, measured with a balloon catheter, ranged from 3 mm to 24 mm with a mean of 10 +/- 3.5 mm. Implantation of the occluder was technically successful in all patients (two attempts in four patients). Seven different devices were used: 26 Sideris buttoned, 11 ASDOS, 19 Angel Wings, 98 PFO-Star, 37 Cardioseal-Starflex, 57 Amplatzer and, 33 Helex devices. One patient suffered from septicemia and subsequently died. In 2 patients, device embolization occurred during or after the procedure (1 Sideris, 1 PFO-Star; catheter retrieval successful). Thirty-seven patients had other minor complications without long-term sequelae: atrial fibrillation within the first weeks after implantation in five patients, asymptomatic thrombus on the device at routine transesophageal echocardiogram (TEE) in 7 patients (1 Angel Wings, 1 ASDOS, 1 CardioSeal, 4 PFO-Star), and device frame fracture in 25 patients (2 Sideris, 4 ASDOS, 1 Angel Wings, 1 CardioSeal, 17 PFO-Star). No complications occurred with the newer devices (Amplatzer and Helex). A residual shunt after 6 months was found in 5.5% of the patients who had completed their 6-month TEE follow-up. In two patients, a second occluder was implanted because of a residual shunt. During a follow-up period of 1 month to 71 months (mean 12 +/- 16 months, 268 patient years), a recurrence of an embolic event (seven TIA, two stroke) occurred in eight patients. None of these occurred with the newer devices (Amplatzer, Helex). Freedom from recurrence of the combined end point of TIA, ischemic stroke, and peripheral embolism was 95.7% (95% CI: 89.0%-98.4%) at 1 year and 94.1% (95% CI: 80.1-98.4%) at 3 years. Catheter PFO closure is a technically simple procedure. With the newer devices and increasing experience, the success rate has improved and the complication rate has decreased. The advantage of the procedure is that closing the defect means a causal treatment. However, catheter closure of PFO despite a very low morbidity has inherent potential risks like any other interventional procedure. Furthermore, selection of patients who definitely have PFO as the cause of their cerebral event has not been defined. For these reasons, further studies are warranted.

Adolescent↗

[Second and Third Annual Report of the German Society of Coronary Angiography and Interventions in Private Practice (BNK) concerning quality assurance in invasive cardiology].

Since 1995, the German Society for Cardiac Angiography and Interventions in Private Practice (BNK) has been intensely involved in quality assurance; since 1996, it has registered relevant data for diagnostic left heart catheterization (DIAG) and coronary interventions (PTCA). The following data are based on a total of 72,777 cardiac catheters, of which 54,513 were DIAG and 18,264 were PTCA (DIAG in 1996: 10,316; in 1997: 15,692 and in 1998: 28,505. PTCA in 1996: 2,597; in 1997: 5,600 and in 1998: 10,067). The mean patient age was 61.9 years for males and 65.3 years for females (31%). DIAG was performed on an out-patient basis in 60% of the cases. The proportion of self-referrals is circa one-third and has not increased over time. A s/p PTCA was present in 21% of the DIAG patients; those after coronary bypass surgery showed a steadily increasing trend towards a follow-up DIAG (8% of the patients). There was a distinctive decrease in the use of contrast medium from an average of 164 ml (1996) to 138 ml (1998). The symptoms leading to DIAG did not substantially change in the years from 1996 to 1998; the angiographic range of the coronary disease and the degree of an impaired myocardial function have remained virtually unchanged. The treatment recommendations appear to tend towards medical therapy with decreasing indications for PTCA (20%) and open heart surgery (16%). The mean duration of a PTCA procedure decreased from 57 +/- 8 (1996) to 44.6 +/- 25 (1998) minutes. The success rates remained unchanged for coronary stenoses as well as for recanalization of chronic total occlusions. PTCA complications: the incidence of abrupt coronary occlusions was 2% and of emergency bypass surgery 0.4%; mortality was 0.1%.

Aged↗

Stent or angioplasty after recanalization of chronic coronary occlusions? (The SARECCO Trial).

This study tests whether stent implantation without anticoagulation after catheter recanalization of coronary occlusions can improve outcome compared with balloon angioplasty alone. One hundred ten patients were randomly assigned to angioplasty alone (no stent group) or stent implantation (stent group) after successful recanalization and balloon angioplasty. The type of stent and angioplasty technique utilized were decided by the operator. The acute procedural success in both groups was 100%. The acute minimal lumen diameter (MLD) was 1.85 +/- 0.44 mm in the no stent group versus 2.54 +/- 0.53 mm in the stent group (p <0.01). The diameter stenosis was 21 +/- 13% versus 3 +/- 14% (p <0.01). This was achieved not only by the stent implantation itself but primarily by a larger maximum balloon diameter in the stent group after stent implantation (3.32 +/- 0.55 mm vs 2.86 +/- 0.4 mm, p <0.05). After 4 months, the MLD was 1.15 +/- 0.73 mm in the no stent group versus 1.81 +/- 0.9 mm in the stent group (p <0.01). The diameter stenosis was 56 +/- 29% versus 34 +/- 28% (p <0.01). After 2 years, event-free survival was 26% in the no stent group and 52% in the stent group (p <0.05). Thus, acute and long-term procedural and angiographic success of stent implantation without anticoagulation after recanalization of total coronary occlusions is superior to that of balloon angioplasty alone. This beneficial effect is mainly the result of the larger balloon diameters, which may be used after stent implantation.

Angioplasty, Balloon↗

A randomized trial comparing the impact of a nonionic (Iomeprol) versus an ionic (Ioxaglate) low osmolar contrast medium on abrupt vessel closure and ischemic complications after coronary angioplasty.

OBJECTIVES: To assess the effect of nonionic versus ionic contrast media on abrupt vessel closure and major ischemic complications after coronary angioplasty. BACKGROUND: There is a continuous debate about the "thrombogenic potential" of nonionic contrast media. The results of both in vitro and in vivo investigations are incongruent. METHODS: We prospectively evaluated the outcomes of 2,000 patients undergoing percutaneous transluminal coronary angioplasty (PTCA). According to a randomized, double-blind protocol, they received either iomeprol (nonionic; n = 1,001) or ioxaglate (ionic; n = 999). Intracoronary thrombus before PTCA was found more often in the iomeprol group (4.2% vs 2.7%, p = 0.04). No other significant differences between both groups were observed with regard to pre-PTCA clinical and angiographic characteristics. RESULTS: The frequency of reocclusions necessitating repeat angioplasty occurring either in laboratory (2.9% with iomeprol and 3.0% with ioxaglate) or out of laboratory (3.1% vs 4.1%) was not significantly different. The rate of major ischemic complications was also comparable after both contrast media (emergency bypass surgery: 0.8% vs 0.7%, myocardial infarction: 1.8 vs 2.0%, cardiac death during hospital stay: 0.2% vs 0.2%). In the iomeprol group, more patients had dissections post-PTCA (30.2% vs 25.0%, p = 0.01) and more patients received intracoronary stents (31.6% vs 25.7%, p = 0.004). Allergic reactions requiring treatment occurred only in the ioxaglate group (0.0% vs 0.9%, p = 0.002). CONCLUSIONS: The nonionic contrast medium was not associated with a higher rate of abrupt vessel closure requiring repeat angioplasty, or major ischemic events. These data suggest that nonionic contrast media do not increase the risk of thrombotic complications in patients undergoing coronary interventions.

Acute Disease↗

Transvenous closure of patent ductus arteriosus with Ivalon plugs. Multicenter experience with a new technique.

RATIONALE AND OBJECTIVE: The authors assess the clinical efficacy of transvenous closure of patent ductus arteriosus (PDA) with a new plug consisting of Ivalon foam and a platinum/iridium frame with four aortic and two pulmonary nitinol struts. The most widely used devices for transcatheter treatment of PDA (Porstmann plug, Rashkind umbrella, Botallo occluder, coils) have specific limitations inherent to their design (e.g., transarterial approach, residual shunts, limited retrieval). METHODS: Between 1994 and 1997, PDA closure was attempted in 33 children and 67 adolescents and adults in 7 clinical centers; PDA diameter was 2 to 11 mm. Plug diameter was 6 to 20 mm, and 8 to 16 F venous sheaths were used for insertion. RESULTS: Placement was successful in 98% (with a single plug in 88%, and a second or third plug in 10%) and unsuccessful in 2%. Plugs were retrieved after malpositioning in 12 of 12 patients and after pulmonary embolization in 2 of 3 patients. One patient underwent surgery for removal of an embolized plug. Complete PDA closure was proved by aortography and color Doppler echocardiography in 85% (40 of 43 patients with a PDA 2-3.9 mm, 30 of 36 patients with a PDA 4-5.9 mm, and 15 of 21 patients with a PDA 6-11 mm). During a median follow-up interval of 16 months, there were no complications (infection, hemolysis, fracture, embolization). CONCLUSION: The new plug device can be used successfully in patients with a PDA diameter up to 11 mm. Further investigations are underway to determine the definite clinical value of this technique.

Adolescent↗

Collagen application for sealing of arterial puncture sites in comparison to pressure dressing: a randomized trial.

UNLABELLED: One-hundred patients undergoing routine diagnostic or interventional catheterization were randomly assigned to receive either percutaneously applied collagen (group A; n = 50) or conventional pressure dressing (group B; n = 50) for sealing of the femoral artery. Clinical variables were comparable in both groups. The heparin dose was 100 IU/kg in 30 patients and 200 IU/kg in 20 patients of either group. The average compression time was 4.3 minutes in group A and 42.3 minutes in group B (p < 0.001). Bleeding was not observed in group A but was observed in 6/50 patients in group B. The time to ambulation was 6.4 hours (range: 4-12 hours) in group A and 21.6 hours (range: 10-48 hours) in group B (p < 0.001). Hematomas with a diameter of > 6 cm developed in 4/50 patients in group A and in 11/50 patients in group B (p < 0.05). Blood transfusion or surgical interventions were not required and there was no loss of ankle pulses in either group. CONCLUSION: Percutaneously applied collagen reduced compression time and duration of bedrest after diagnostic catheterization and PTCA. Despite earlier ambulation, the incidence of bleeding was lower with collagen than with conventional pressure dressing.

Aged↗

Improved systolic function after PTCA can be estimated by femoral arterial Doppler.

The effect of coronary angioplasty to the post exertional femoral arterial pulse was analyzed in a prospective trial. In 26 patients 30 coronary stenoses could be treated. Narrowed lumen diameter dropped from 85.5% +/-8.2 to 34.6% +/-10.7 (P<0.0001). Patients with a residual coronary artery stenosis of <60% (group A, n=15) were compared to those with incomplete revascularisation (stenoses >60%, group B, n=11). Post exertional Doppler criteria differed between both groups: Peak velocity in group A was 86.08 cm/s +/- 17.8, in group B 72.9 cm/s +/-17, mean velocity 32.06 cm/s +/-12.5 versus 23.6 cm/s +/-10.3 acceleration or dV/dt 813.5 cm/s2 versus 722 cm/s2 +/-164. Statistical significant pre to post postexertional findings improved only in group A (P<0.01, peak velocity, P<0.05 mean velocity and dV/dt). It is concluded that patients with still-existing exertional myocardial ischemia can be distinguished from those without hemodynamic relevant stenoses by means of a simple noninvasive Doppler analysis of femoral arterial pulse.

Angioplasty, Balloon, Coronary↗

Initial clinical experience with the new EBI (BARD-XT) flexible coronary stent: acute results and follow-up.

The EBI (BARD-XT, C.R. Bard, Murray Hill, NJ) stent is a new radiopaque balloon expandable coronary stent with high resistance to external radial forces. It does not shorten significantly with expansion and allows stent implantation in bifurcation lesions. A total of 28 EBI stents were implanted in 23 lesions in 21 patients. Indications for stent implantation were acute closure in 1, threatened closure in 15, and electively in 7 lesions. In 2 cases, the lesion involved a bifurcation where a stent was implanted in both vessels. All patients received aspirin and ticlopidine. No anticoagulant therapy was given. The stenting procedure was successful in 22 of 23 lesions. No complications occurred with the exception of 1 patient with a thrombotic reocclusion within 1 hr after stent implantation and 1 patient with a temporary occlusion of a side branch. The mean minimal luminal diameter (MLD) increased from 0.74+/-0.46 mm before balloon dilatation to 1.27+/-0.62 mm before stent implantation and 2.32+/-0.57 mm after stent implantation. Percent stenosis decreased from 71+/-19% before angioplasty to 46+/-25% after angioplasty to 5+/-8% after stent implantation. MLD at the time of follow-up angiography after 4 months was 1.98+/-0.77 mm and percent stenosis was 26+/-21%. Restenosis of more than 50% occurred in 2 lesions. In these lesions, a second percutaneous transluminal coronary angioplasty was performed. Advantages of this stent are its flexibility together with an acceptable radial strength as well as enabling radiopacity without obscuring the arterial lumen. Stenting of bifurcation lesions is possible.

Angioplasty, Balloon, Coronary↗

Percutaneous closure of secundum atrial septal defect with a new self centering device ("angel wings").

OBJECTIVE: To investigate the safety, efficacy, and clinical application of a new self centering device ("angel wings") for closure of secundum atrial septal defects (ASD II) and persistent foramen ovale in all age groups. DESIGN: Multicentre, prospective, nonrandomised study. PATIENTS INCLUSION CRITERIA: defects with an occlusive diameter of < or = 20 mm and a surrounding rim of > 4 mm; body weight > 10 kg; and an indication for surgical closure of secundum atrial septal defect. Additionally, there were compassionate indications for closure in patients with persistent foramen ovale. INTERVENTIONS: Defects were closed by a transcatheter device consisting of two square frames made of superelastic nitinol wire. The frames are covered by elastic polyester fabric, which is sewn together at a central circle. All procedures, except for three interventions that were carried out under sedation, were performed under general anaesthesia using transoesophageal echocardiography and fluoroscopy to monitor intervention. RESULTS: Closure was attempted in 75 (71%) of 105 patients. An ASD II was present in 35 children and 15 adults. A persistent foramen ovale was present in 25 adults with suspected paradoxical embolism. Transcatheter closure was unsuccessful in three children and crossover to surgery was required. Residual shunts were found in 20 patients (27%) immediately after the procedure. A transient atrioventricular third degree block occurred in three patients (4%) and the right atrial disk was not fully deployed in three. A minor shunt (< 3 mm) was present in only three (4%) of 72 patients during follow up of 1-17 months. Blood clots on the right atrial disks in two patients (one required lysis) were seen during follow up transoesophageal echocardiography. Serious complications demanding surgical removal of the device occurred in three patients. One patient had haemopericardial tamponade because of an aortic lesion. Left atrial thrombus formation due to an unfolded right atrial disk was found in a second patient and dislodgement of the left atrial disk resulted in a large residual shunt in a third. CONCLUSIONS: Percutaneous closure of a central ASD with a diameter < or = 20 mm in paediatric and adult patients is feasible and effective with this new device. It is a promising alternative to surgical closure. Modifications of the design, however, seem to be mandatory as 4% of patients developed serious complications.

Adolescent↗

Right ventricular function before and after percutaneous balloon mitral valvuloplasty.

Aim of this study was to evaluate right ventricular performance in patients with mitral stenosis and its modification by balloon valvuloplasty. Right ventricular volumes of 24 patients with postrheumatic mitral stenosis were determined by thermodilution 1 or 2 days before and 1 or 2 days after valvuloplasty. Right ventricular ejection fraction at rest was 43 (36-47)% (median and interquartile range). Right ventricular end-diastolic volume was 100 (86-119) ml/m2. Supine bicycle exercise (50 Watt) reduced right ventricular ejection fraction to 30 (29-37)% (P < 0.0001) and increased right ventricular end-diastolic volume to 124 (112-141) ml/m2 (P < 0.0001). At rest, right ventricular ejection fraction correlated inversely with pulmonary vascular resistance (r = -0.64, P < 0.0001), while no significant correlation with mitral valve area was found. Valvuloplasty increased right ventricular ejection fraction at rest to 48 (44-50)% (P < 0.005), and during exercise to 42 (38-45)% (P < 0.0001). This improvement of right ventricular ejection fraction correlated inversely with the value of this parameter before valvuloplasty (r = -0.88, P < 0.0001) and with the gain in stroke volume (r = 0.57, P < 0.01). The right ventricular function curve, disturbed before commissurotomy, was reestablished by the procedure. In conclusion, at the here investigated stage of mitral stenosis right ventricular function is reversibly impaired. This is predominantly caused by the hemodynamic consequences of the valvular defect and not by an impairment of right ventricular myocardial function.

Adult↗

[A new system for transvenous occlusion of persistent ductus arteriosus].

An Ivalon-plug (PDA-plug) has been developed for transvenous closure of patent ductus arteriosus. It can be introduced into the ductus through standard venous sheaths with a diameter of 8-16 French. The plug is fixed in its target position by means of four distal (aortal) and two proximal (pulmonary) nitinol struts. In case of malpositioning the system can be pulled back into and retrieved through the sheath. In animal experiments endothelialization of the implanted material was demonstrated. PDA-closure was attempted in 58 patient; the procedure was successful in 57 cases; a residual ductal flow was present in eight patients. During a follow-up of up to 24 months there were no complications.

Adolescent↗

[Balloon dilatation of valvular pulmonary stenoses in adults].

Balloon valvuloplasty of pulmonary stenosis has become the treatment of choice in children and adults. This is a report about the long term results in adult patients. Forty-six patients (mean age 37 +/- 17 years) with pulmonary stenosis were treated between 1984 and 1994 by this method. Thirty-four of 46 patients were re-examined 3 months to 9 years (mean 3.4 years) later by right heart catheterization and echocardiography. These 34 patients were representative for the whole group concerning age, severity of the pulmonary stenosis, and acute results after the intervention. The pressure gradient was acutely reduced by balloon valvuloplasty from 86 +/- 35 to 38 +/- 17 mm Hg (p < 0.0001) (n = 46) and was 32 +/- 10 mm Hg (n.s.) (n = 34) at follow-up. Within 3 months after the intervention, 8 of 13 patients with a pressure gradient > or = 100 mm Hg, showed spontaneously further reduction of the gradient due to the resolution of the subvalvular muscular hypertrophy. During a bicycle exercise test with 9 patients, the gradient rose significantly from 29 +/- 10 to 53 +/- 23 mm Hg (p < 0.01) as determined by right heart catheterization. All of these patients had normal cardiac output at rest and during exercise. None had signs of right ventricular hypertrophy in the electro- or echocardiogram. It is concluded that balloon valvuloplasty of pulmonary stenosis is the first line treatment in adults.

Adult↗

Transcatheter closure of patent ductus arteriosus with the Rashkind occluder. Acute results and angiographic follow-up in adults.

We performed catheter closure of a patent ductus arteriosus with a Rashkind occluder in 51 adult patients (aged 14 to 76 years). The diameter of the ductus ranged from 2 to 13 mm (mean 4.5 +/- 2.0 mm), QP:QS from 1.0 to 2.6 (mean 1.6 +/- 0.3). The procedure was successful in 50/51 patients, in one of them at a second attempt. In one patient, the ductus could not be closed even with additional occluders. This patient was sent for surgery. In two patients with a large ductus, two Rashkind umbrellas were implanted simultaneously. Immediately after ductus closure, there was a residual shunt in 40/50 patients decreasing to 26/50 after 20 min. Two of the patients with a residual shunt suffered from haemolysis. In 16 patients, the residual shunt disappeared spontaneously within some months. In 15 patients, additional occluders (a second occluder in 12, a third occluder in one, and a fourth and fifth occluder in another) were implanted during the initial procedure or during follow-up. All patients were followed until angiography proved complete closure of the ductus. At the time of the last follow-up angiogram, the ductus was occluded in 49/50 patients; one patient refused a follow-up angiogram. Ductus occlusion with the Rashkind umbrella can be considered a technique with a high success rate and low rate of complications in adults. However, a residual shunt is not uncommon. Additional occluders have to be implanted in many patients.

Adolescent↗

Retrievable patent ductus arteriosus plug for interventional, transvenous occlusion of the patent ductus arteriosus. Evaluation in lambs and preliminary clinical results.

RATIONALE AND OBJECTIVES: The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous plug device for the occlusion of the persistent patent ductus arteriosus (PDA). METHODS: A foam plug (polyvinyl alcohol) is mounted on a titanium core pin where, at both ends, small legs (titanium nickel alloy) with titanium heads are anchored, to ensure safe fixation in the ductus. The device is introduced transvenously through a long sheath (Mullins sheath) and held by a modified biopsy forceps allowing complete retrieval until final release. A common lamb model of large PDAs (n = 11) was used to test for practicability and the histomorphologic outcome. Clinical results were obtained from a consecutive series of 16 patients (aged 13 to 71 years). RESULTS: In all lambs, placement of the plug within the PDA was possible. Histopathology (follow-up 10 to 215 days; mean 112 days) revealed an adequate ingrowing of the device and no pathologic foreign body reaction. The diameter of the human PDAs ranged from 3 to 7 mm (mean 5 mm). The size of the sheath used for introducing the plug (diameter 8 to 16 mm) ranged from 8 to 16 French. Fourteen of 16 PDAs were closed immediately after or on day 1 after implantation, 1 was closed after the 12-month follow-up, and 1 needed an additional plug after 30 months for definitive closure. CONCLUSIONS: The device demonstrated practicability and biocompatibility in our experimental lamb model and effectively closed the PDA in a consecutive series of 16 patients. A greater number of patients and a longer follow-up period are necessary for the definitive clinical assessment of the new device.

Adolescent↗

Thrombogenic potential of non-ionic contrast media--fact or fiction?

The role of contrast media in determining the occurrence of thromboembolic complications is not easy to define. Contrast media have a series of effects on blood constituents and on the hemostatic system. As for in vitro studies, it is generally agreed that ionic contrast media are stronger anticoagulants than nonionic, this being due to the fact that nonionic media are more inert on biological systems. This has been confirmed also in a recent paper comparing a nonionic monomer (iopamidol) with an ionic monomer (diatrizoate) and an ionic dimer (ioxaglate). Clinical data failed to demonstrate a greater thrombogenicity of one class of contrast media with respect to the other. The occurrence of thromboembolic complications in coronary angiography and PTCA is mostly related to operator experience and type of angiographic procedure.

Angioplasty, Balloon, Coronary↗