Prospective angiographic comparison of direct, endoscopic, and telesurgical approaches to harvesting the internal thoracic artery.

BACKGROUND: The purpose of this study was to compare the quality of left internal thoracic arteries harvested by the conventional open approach versus minimally invasive videoscopic and robotic-assisted telesurgical techniques. METHODS: One hundred and fifty consecutive patients with single vessel coronary artery disease were prospectively studied. The left internal thoracic artery was harvested using three different approaches, with 50 patients consecutively assigned to each group. The off-pump coronary artery bypass (OPCAB) group underwent median sternotomy with direct visualization. The automated endoscopic system for optimal positioning (AESOP) group employed the AESOP 3000 system (Computer Motion Inc, Goleta, CA) for robotic-assisted visualization with endoscopic manual left internal thoracic artery harvesting. The Zeus group used the Zeus robotic telesurgical system (Computer Motion Inc) and internal thoracic artery harvesting was performed remotely from a surgical console. Postanastomotic left internal thoracic artery flows and day one postoperative angiography were used to assess internal thoracic artery quality and patency. RESULTS: Average left internal thoracic artery harvest times were 23 +/- 2.5, 63.3 +/- 20.3, and 66.1 +/- 17.9 minutes in the OPCAB, AESOP, and Zeus groups, respectively (p < 0.001, OPCAB vs AESOP and Zeus). Intraoperative graft flows averaged 28.1 +/- 11.9, 33.7 +/- 19.3, and 36.9 +/- 24.6 mL/minute, respectively in the OPCAB, AESOP, and Zeus groups (p = 0.317, OPCAB vs AESOP and Zeus). There was no significant angiographic difference in the patency rate of the harvested left internal thoracic arteries in the three groups (p = 0.685, overall). CONCLUSIONS: The left internal thoracic artery can be harvested safely and effectively using minimally invasive videoscopic and robotic-assisted telesurgical techniques. Although the less invasive approaches require specialized equipment and training as well as increased operative time, they offer the potential for less traumatic myocardial revascularization through smaller incisions and reduced postoperative morbidity.

Adult↗

Robotic-assisted left atrial ligation for stroke reduction in chronic atrial fibrillation: a case report.

Patients with atrial fibrillation are at significant risk for sustaining a thromboembolic stroke. More than 90% of thromboemboli form in the left atrial appendage. Ligation of the left atrial appendage to reduce the risk of stroke is often performed in connection with other cardiac surgical procedures. As a stand-alone procedure, however, left atrial ligation has generally been deemed too invasive and has gained little support as an alternative therapeutic option. We report a case of port-access robotic-assisted left atrial ligation as a stand-alone procedure in a patient with chronic atrial fibrillation in whom anticoagulation was a contraindication. To our knowledge, this is the first reported case of stand-alone robotic-assisted left atrial ligation in the literature.

Aged↗

Computer-enhanced telemanipulation in mitral valve repair: preliminary experience in Canada with the da Vinci robotic system.

BACKGROUND: Investigation into the surgical application of robot technology continues to expand. We report on the first case series of robotic-assisted mitral valve (RAMV) repair in Canada with use of the da Vinci telemanipulation system (Intuitive Surgical, Sunnyvale, Calif.). METHODS: Between February 2004 and August 2004, 10 patients with normal left ventricular function and severe mitral valve regurgitation underwent RAMV repair with use of the da Vinci system. Peripheral cardiopulmonary bypass, transthoracic aortic cross-clamping and antegrade cardioplegia were used in all cases. A minithoracotomy in the fourth intercostal space and 2 ports in the third and fifth intercostal spaces allowed surgical access. All mitral valve valvuloplasties and band annuloplasties were done endoscopically with robotic assistance. RESULTS: Nine of 10 patients had successful valve repair, and 1 had conversion to mitral valve replacement due to persistent regurgitation. There were no deaths, strokes or need for sternotomy. One patient required re-exploration for bleeding. CONCLUSION: Minimally invasive RAMV repair is feasible and safe with promising early postoperative results when performed by experienced surgical personnel accomplished in both mitral valve procedures and robotic techniques.

Adult↗

Concurrent robotic hybrid revascularization using an enhanced operative suite.

Hybrid myocardial revascularization combines coronary surgery with percutaneous intervention as an alternative therapy for ischemic heart disease. The order and sequence of the hybrid approach is not yet clearly defined. We report on the benefits of an enhanced surgical suite equipped with a carbon fiber operating table and digital C-arm for robotic-assisted hybrid revascularization in a single operative sequence. To our knowledge, this is the first reported case of concurrent robotic-assisted hybrid revascularization utilizing an enhanced operative suite.

Angioplasty, Balloon, Coronary↗

Primary purulent pericarditis due to group C Streptococcus.

In the antibiotic era, purulent pericarditis, an infection associated with high mortality, is uncommon. The causative organism is generally Staphylococcus aureus or Streptococcus pneumoniae arising from contiguous spread or hematogenous dissemination of an underlying infection elsewhere in the body. The present report describes a previously healthy individual who presented with acute infectious pericarditis with the offending organism identified as Lancefield group C Streptococcus equi. After an initial pericardial window was unable to prevent recurrent pericardial effusion, pericardiectomy was performed and the patient slowly recovered from the incident.