PubMed Health⌕ Search

Biomedical subjects

R Setser

Publications and source records attributed to R Setser.

2 recordsLinked to original sources

Left ventricular contractility is impaired following myocardial infarction in the pig and rat: assessment by the end systolic pressure-volume relation using a single-beat estimation technique and cine magnetic resonance imaging.

The end systolic pressure-volume relation (ESPVR) has been shown to be a relatively load independent measure of left ventricular (LV) contractility. Recently, several single-beat ESPVR computation methods have been developed, enabling the quantification of LV contractility without the need to alter vascular loading conditions on the heart. Using a single-beat ESPVR method, which has been validated previously in humans and assumes that normalized elastance is constant between individuals of a species, we studied the effects of myocardial infarction on LV contractility in two species, the rat and the pig. In our studies, LV pressure was acquired invasively and LV volume determined noninvasively with magnetic resonance imaging, at one week postinfarction in pigs and at 12 weeks postinfarction in rats. Normalized systolic elastance curves in both animal species were not statistically different from that of humans. Also, the slope of the ESPVR (Ees) decreased significantly following infarction in both species, while the volume-axis intercept (V0) was unaffected. These results indicate that a single-beat ESPVR method can be used to measure the inotropic response of the heart to myocardial infarction, and that the basis for this method (i.e., constant normalized elastance) is applicable to a variety of mammalian species.

Animals↗

Left ventricular chamber stiffness from model-based image processing of transmitral Doppler E-waves.

BACKGROUND: Model-based image processing (MBIP) of Doppler E-waves eliminates the need for digitizing waveforms by hand or determining the contour 'by eye'. Little et al. (Circulation 1995, 92:1933-1939) used pressure-volume measurements for dogs to verify the physiologic-model-derived prediction that the left ventricular chamber stiffness, KLV1 can be determined from the deceleration time tdec, when that portion of the E-wave contour is fit by a cosine function. MBIP of clinical Doppler E-wave images to determine chamber stiffness KLV has not been performed. OBJECTIVE: We sought to determine KLV by MBIP of clinical Doppler E-wave images and elucidate the physiologic meaning of the harmonic oscillator filling model's parameter k. METHODS AND RESULTS: The unique mathematical relationship between the kinematic, harmonic oscillator model of filling and KLV predicts that the oscillator's spring constant k be linearly proportional to the chamber stiffness KLV. To verify this, digitally acquired, clinical Doppler transmitral flow velocity images from 21 subjects were analyzed. The parameter k and the stiffness KLV were computed independently for each subject and compared. In accordance with prediction, a linear relationship between k and the stiffness KLV, namely k = 1.16 [A/(rho L)]KLV+41, r = 0.96, was observed. CONCLUSIONS: The oscillator parameter k is linearly proportional to the left ventricular chamber stiffness KLV. The MBIP approach allows automated computation of k and KLV, provides a robust, automated, observer independent method of Doppler transmitral flow velocity analysis, and eliminates the need for visual determination of the contour or measurement of its attributes by eye. It provides a stimulus for further validation of the relationships among K, KLV, and catheterization-based diastolic chamber properties in humans and their correlations with selected diastolic function-altering syndromes.

Blood Flow Velocity↗