Triceps brachii muscle demonstrating a fourth head.

Variations of the triceps brachii muscle are apparently rare. We report an additional attachment site of the medial head of the triceps brachii found on the left side of a male cadaver. This head originated from the posterior aspect of the surgical neck of the humerus. Clinicians diagnosing or treating patients with weakness or pain of the posterior arm should consider anomalous muscles in this region that may result in neurovascular compression.

Aged↗

The use of a sump antibiotic irrigation system to save infected hardware in a patient with a vagal nerve stimulator: technical note.

The authors describe the use of a sump irrigation system that was used to successfully treat the battery implantation site of a vagal nerve stimulator (VNS). Irrigation was composed of a dilution of vancomycin in lactated Ringer's solution. At long-term follow up, the patient has not returned with signs or symptoms of wound infection. She continues to effectively combat her epilepsy with VNS. The authors believe this to be the first description of this technique for salvaging an implanted VNS.

Anti-Bacterial Agents↗

Vidius Vidius (Guido Guidi): 1509-1569.

LITTLE IS KNOWN of the early physician/anatomist Vidius Vidius (Guido Guidi). Anatomic structures named after Vidius include the Vidian nerve, artery, and canal and are well known to neurosurgeons. His anatomic treatise was printed under the title Vidi Vidii: Florentini de anatome corporis humani libri VII in a posthumous edition (1626). We report what is known regarding this historical figure of both early anatomy and medicine.

Anatomy↗

The marginal sinus.

OBJECT: Descriptions of the marginal venous sinus are lacking in the extant medical literature. The aim of this study was to characterize the anatomy of this intracranial venous sinus. METHODS: The authors examined the marginal sinuses in 15 adult cadavers following the injection of latex into the intracranial venous system. The maximal vertical height of the sinuses, which ranged from 7 to 15 mm (mean 10 mm), was located at the lateral aspect of the foramen magnum at or near the region at which the spinal accessory nerve crossed en route to the jugular foramen. In all specimens the sinus tapered as it traveled both anteriorly and posteriorly. Ninety-three percent of the specimens demonstrated significant drainage into the veins of the hypoglossal canal. The hypoglossal nerve rootlets pierced the sinus and its tributaries in 11 (73%) of 15 specimens. The marginal sinus communicated with the basilar venous plexus in 12 (80%) of 15 specimens and with the occipital sinus in all specimens (100%). There was venous communication with the sigmoid sinus in all specimens. The vertebral artery coursed through the marginal sinus as it pierced the posterior atlantooccipital membrane in all left sides and in 87% of the right sides. CONCLUSIONS: These quantitative data will be useful to the neurosurgeon who operates in the region of the marginal sinus.

Aged↗

Quantitation of and superficial surgical landmarks for the anterior interosseous nerve.

OBJECT: There are scant data regarding the anterior interosseous nerve (AIN) in the neurosurgical literature. In the current study the authors attempt to provide easily identifiable superficial osseous landmarks for the identification of the AIN. METHODS: The AIN in 20 upper extremities obtained in adult cadaveric specimens was dissected and quantified. Measurements were obtained between the nerve and surrounding superficial osseous landmarks. The AIN originated from the median nerve at mean distances of 5.4 cm distal to the medial epicondyle of the humerus and 21 cm proximal to the ulnar styloid process. The distance from the origin of the AIN to its branch leading to the flexor pollicis longus muscle and to the point it travels deep to the pronator quadratus (PQ) muscle measured a mean 4 and 14.4 cm, respectively. The mean distance from the AIN branch leading to the flexor pollicis longus muscle to the proximal PQ muscle was 12.1 cm, and the mean distance between this branch and the ulnar styloid process was 7.2 cm. The mean diameter of the AIN was 1.6 mm at the midforearm. CONCLUSIONS: Additional landmarks for identification of the AIN can aid the neurosurgeon in more precisely isolating this nerve and avoiding complications. Furthermore, after quantitation of this nerve, the AIN branches can be easily used for neurotization of the median and ulnar nerves, and with the aid of a transinterosseous membrane tunneling technique, passed to the posterior interosseous nerve.

Aged↗

Surgical anatomy of the cervical and infraclavicular parts of the long thoracic nerve.

OBJECT: There is insufficient information in the neurosurgical literature regarding the long thoracic nerve (LTN). Many neurosurgical procedures necessitate a thorough understanding of this nerve's anatomy, for example, brachial plexus exploration/repair, passes for ventriculoperitoneal shunt placement, pleural placement of a ventriculopleural shunt, and scalenotomy. In the present study the authors seek to elucidate further the surgical anatomy of this structure. METHODS: Eighteen cadaveric sides were dissected of the LTN, anatomical relationships were observed, and measurements were obtained between it and surrounding osseous landmarks. The LTN had a mean length of 27 +/- 4.5 cm (mean +/- standard deviation) and a mean diameter of 3 +/- 2.5 mm. The distance from the angle of the mandible to the most proximal portion of the LTN was a mean of 6 +/- 1.1 cm. The distance from this proximal portion of the LTN to the carotid tubercle was a mean of 3.3 +/- 2 cm. The LTN was located a mean 2.8 cm posterior to the clavicle. In 61% of all sides the C-7 component of the LTN joined the C-5 and C-6 components of the LTN at the level of the second rib posterior to the axillary artery. In one right-sided specimen the C-5 component directly innervated the upper two digitations of the serratus anterior muscle rather than joining the C-6 and C-7 parts of this nerve. The LTN traveled posterior to the axillary vessels and trunks of the brachial plexus in all specimens. It lay between the middle and posterior scalene muscles in 56% of sides. In 11% of sides the C-5 and C-6 components of the LTN traveled through the middle scalene muscle and then combined with the C-7 contribution. In two sides, all contributions to the LTN were situated between the middle scalene muscle and brachial plexus and thus did not travel through any muscle. The C-7 contribution to the LTN was always located anterior to the middle scalene muscle. In all specimens the LTN was found within the axillary sheath superior to the clavicle. Distally, the LTN lay a mean of 15 +/- 3.4 cm lateral to the jugular notch and a mean of 22 +/- 4.2 cm lateral to the xiphoid process of the sternum. CONCLUSIONS: The neurosurgeon should have knowledge of the topography of the LTN. The results of the present study will allow the surgeon to better localize this structure superior and inferior to the clavicle and decrease morbidity following invasive procedures.

Axilla↗

Superficial surgical landmarks for identifying the posterior interosseous nerve.

OBJECT: There is a paucity of information in the neurosurgical literature regarding the surgical anatomy surrounding the posterior interosseous nerve (PIN). The goal of the current study was to provide easily recognizable superficial bone landmarks for identification of the PIN. METHODS: Thirty-four cadaveric upper extremities obtained from adults were subjected to dissection of the PINs, and measurements were made between this nerve and surrounding superficial bone landmarks. In all specimens the main radial trunk was found to branch into its superficial branch and PIN at the level of the lateral epicondyle of the humerus. Proximally, the PIN was best identified following dissection between the brachioradialis and extensor carpi radialis longus and brevis muscles. At its exit site from the supinator muscle, the PIN was best identified after retraction between the extensor carpi radialis longus and brevis and extensor digitorum communis muscles. This site was a mean distance of 6 cm distal to the lateral epicondyle of the humerus. No compression of the PIN by the tendon of origin of the extensor carpi radialis brevis muscle was seen. One specimen was found to have a proximally split PIN that provided a previously undefined articular branch to the elbow joint. The mean diameter of the PIN proximal to the supinator muscle was 4.5 mm. The leash of Henry crossed the PIN in all but one specimen and was found at a mean distance of 5 cm inferior to the lateral epicondyle. The PIN exited the distal edge of the supinator muscle at a mean distance of 12 cm distal to the lateral epicondyle of the humerus. Here the mean diameter of the PIN was 4 mm. The exit site from the distal edge of the supinator was found to be at a mean distance of 18 cm proximal to the styloid process of the ulna. This exit site for the PIN was best identified following dissection between the extensor carpi radialis longus and brevis and extensor digitorum communis muscles. The distal articular branch of the PIN was found to have a mean length of 13 cm and the proximal portion of this terminal segment was located at a mean distance of 7.5 cm proximal to the Lister tubercle. CONCLUSIONS: The addition of more anatomical landmarks can help the neurosurgeon to be more precise in identifying the PIN and in avoiding complications during surgery in this region.

Aged↗

Quantitation of and landmarks for the muscular branches of the ulnar nerve to the forearm for application in peripheral nerve neurotization procedures.

OBJECT: In neurotization procedures, donor nerves--either whole or in part-with relatively pure motor function can be carefully chosen to provide the optimal nearby motor input with as little donor site morbidity as possible. In this context, the ulnar nerve branches to the forearm muscles are relatively dispensable; however, quantitation of and landmarks for these branches are lacking in the literature. METHODS: The ulnar branches to the flexor carpi ulnaris (FCU) and flexor digitorum profundus (FDP) muscles in 20 upper extremities obtained in adult cadaveric specimens were dissected and quantified. In the forearm, a mean of four nerve branches led to the FCU and FDP muscles. A mean of 3.4 branches led to the FCU muscle; of these, one to three were medial branches and zero to two were lateral. Medial branches to the FCU muscle originated a mean of 2.7 cm inferior to the medial epicondyle. Lateral branches to the FCU muscle originated at a mean of 3.3 cm inferior to the medial epicondyle. The mean length of the medial branches was 3.2 cm, whereas the mean length of the lateral branches was 3.3 cm. All nerves had a single trunk for the FDP muscle, and in all specimens this branch was located deep to the main ulnar nerve trunk, originating from the ulnar nerve a mean of 2.7 cm inferior to the medial epicondyle. These branches had a mean length of 5.6 cm. The mean diameter of all medial and lateral branches to the FCU muscle was 1 mm, and the mean diameter of the branch to the FDP muscle was 2.1 mm. All branches to both the FCU and FDP muscles arose from the ulnar nerve, over its first approximately 5 cm from the level of the medial epicondyle. Additionally, all branches could be easily lengthened by gentle proximal dissection from the main ulnar nerve. CONCLUSIONS: Ulnar branches to the forearm can be easily localized and used for neurotization procedures. The branch to the FDP muscle had the greatest diameter and longest length, easily reaching the median nerve and posterior interosseous nerve via a transinterosseous membrane tunneling procedure. Furthermore, this branch could be teased away from the main ulnar nerve trunk and made to reach the distal branches of the musculocutaneous nerve in the arm.

Aged↗

The patient with symptoms following resection of a lipomyelomeningocele: do increases in the lumbosacral angle indicate a tethered spinal cord?

OBJECT: The angulation of the sacrum is easily measured. The authors have previously reported on patients who were symptomatic with a diagnosis of myelomeningocele who were found to have changes in their lumbosacral angle (LSA) corresponding to the onset of symptoms indicative of a tethered spinal cord. The aim of this study was to verify this same finding in a group of patients with occult spinal dysraphism (that is, closed neural tube defect). METHODS: A retrospective analysis of 50 consecutive lipomyelomeningocele repair procedures was performed. Data pertaining to 30 age-matched control patients were also analyzed. Measurements were made of the LSA over time in all studied patients harboring lipomyelomeningoceles. Appropriate imaging was available for 25 cases of lipomyelomeningocele (that is, radiographs of the lumbosacral junction were available from the patient's perinatal period and at presentation of symptoms of a tethered spinal cord). Roughly one third of these patients suffered symptoms from a tethered spinal cord at the most recent follow-up examination. Nine patients (36%) were found to have corresponding LSA measurements greater than 70 degrees, and seven (28%) of these patients presented with signs and symptoms of a tethered spinal cord, such as decreased lower-extremity function (two patients), urinary bladder incontinence (three patients), back pain (one patient), and lower-extremity paresthesias (one patient). The LSA measurements were statistically greater (p < 0.05) in the symptomatic patient population than in age-matched control patients and asymptomatic patients. Changes in the LSA in these symptomatic patients ranged from 5 to 24 degrees (mean 13 degrees). Changes in the LSA were noted in only two asymptomatic patients. No single sign or symptom of a tethered spinal cord appeared to correlate to any degree of increase in the LSA. Of the 25 patients excluded from this study because perinatal radiographic images were not available, none was symptomatic at the most recent follow-up examination and none had a grossly exaggerated LSA. CONCLUSIONS: Signs and symptoms indicative of a tethered spinal cord appear to correspond to increases in the LSA. Although the authors do not advocate the use of LSA measurement as the sole indicator of a tethered spinal cord, this imaging finding may prove useful to the clinician as an indication of the tethered spinal cord or as an adjunct in verifying symptomatology in patients harboring a lipomyelomeningocele.

Adolescent↗

Pericallosal artery pseudoaneurysm secondary to endoscopic-assisted ventriculoperitoneal shunt placement. Case report.

Complications following cerebrospinal fluid (CSF) diversion procedures are protean. The formation of pseudoaneurysms after the placement of a ventricular catheter as part of a CSF diversion procedure is presumably quite rare. The authors report the case of a child in whom a pericallosal artery pseudoaneurysm developed following the endoscopic insertion of a ventricular catheter as part of a ventriculoperitoneal shunt placement procedure. Significant intraventricular bleeding signaled vascular injury. Angiography revealed a right pericallosal artery pseudoaneurysm. The patient subsequently underwent surgical trapping of his pseudoaneurysm and physical therapy for left leg monoparesis. This appears to be the first reported case of pseudoaneurysm formation following the placement of a ventricular catheter for a CSF diversion procedure. This case underlines a rare but serious risk involved with the routine placement of CSF shunts.

Aneurysm, False↗

The intracranial entrance of the atlantal segment of the vertebral artery in crania with occipitalization of the atlas.

OBJECT: An anomalous vertebral artery (VA) position can jeopardize an otherwise successful procedure, such as a posterior cranial fossa decompression for hindbrain herniation, and may increase the propensity for VA occlusion. METHODS: The authors describe the detailed anatomy of the entrance site of the VA in adult human crania in which there is occipitalization of the atlas. They found that if the atlantal posterior arch or hemiarch was fused to the occiput one should anticipate encountering an anomalous osseous pathway as the VA enters into the cranium, as evidenced by this finding in 80% of their specimens. An anomalous entry pathway was present in all but one left-sided specimen in which the left posterior hemiarch was not fused to the occiput and one right-sided specimen in which there was an unfused and rudimentary posterior arch of the atlas. CONCLUSIONS: The clinician should consider the possibility that the VA takes anomalous routes into the skull in cases in which there is occipitalization of the atlas.

Atlanto-Axial Joint↗

Exposure of the V1-V3 segments of the vertebral artery via the posterior cervical triangle: a cadaveric feasibility study.

OBJECT: Surgical exposure of the extracranial part of the vertebral artery (VA) is occasionally necessary. Historically, the greater portion of the extracranial portion of the VA has been approached by traversing the anterior cervical triangle. The authors speculated that this entire segment of the VA could be reached with equal efficacy via the posterior cervical triangle (PCT). METHODS: Six adult cadavers underwent dissection of the left and right VAs via the PCT. The entire extracranial VA was easily exposed through this approach. Only three of 12 sides required the transection of the clavicular head of the sternocleidomastoid muscle for exposure of the most proximal segment of the VA as it originated from the subclavian artery. No gross injury to the VA or other regional vessels or nerves was noted. CONCLUSIONS: The authors found that the extracranial VA can be exposed easily through the PCT. Following confirmation of this technique in vivo, this approach may be added to the surgeon's armamentarium for exposing the extracranial segment of the VA.