PubMed Health⌕ Search

Biomedical subjects

R Slama

Publications and source records attributed to R Slama.

At least 37 records · Page 2Linked to original sources

[Observations on the implantable automatic defibrillator].

Thanks to the fantastic job made by Michel Mirowski, the automatic implantable cardioverter-defibrillator is now an effective treatment for patients with malignant, life-threatening arrhythmias. And in the last ten years, many technical improvements have been made (weight, size, reconfirmation, Holter function, endocardial implantation). But if sudden death has been significantly reduced in implanted patients, the long term global cardiac mortality remains very high in these people. This explains why the indications to implant such an expensive device are difficult to define. Apart from special cases in which the indications (or contraindications) are obvious, many factors must be taken into consideration, including the presentation of the arrhythmia, the results of the programmed ventricular stimulation, and the underlying cardiac disease. The European society of Cardiology has published guidelines for the use of A.I.C.D., but from our own experience in Hospital Lariboisière (Paris, France) we have learned that each case must be discussed; and, if it is possible to suggest some therapeutic orientations, it is yet illusory to believe that decisional algorithms will solve all the problems.

Arrhythmias, Cardiac↗

[Pericardial constriction caused by epicardial patches of automatic implantable defibrillators. Apropos of 3 cases].

The authors report three cases of pericardial constriction secondary to implantation of an automatic defibrillator. In one case, the pericardial constriction occurred 1 year after implantation and was associated with ascending infection of the patch electrodes from the stimulator; the patient died when the patch electrodes were removed, the infection having eroded the left ventricular wall. In the other two cases, signs of constriction appeared 2 years after implantation. In one of these patients, surgery showed a fibrous pericardial reaction deforming the patch electrodes with a favourable outcome when the electrodes were removed. The other patient refused surgery. In the three cases, the diagnosis was confirmed by right heart catheterisation and ventriculography which showed signs of adiastole and severe deformation of the ventricular contours. Pericardial constriction due to patch electrodes is a potentially serious complication of implantable automatic defibrillators, the prevalence of which may be underestimated. The use of endocavitary or extra-pericardial electrodes should avoid this complication.

Defibrillators, Implantable↗

[Catheter ablation of atrioventricular nodal reentrant tachycardia].

Electrophysiological data of atrioventricular nodal reentrant tachycardia recensed over the last 40 years in the animal and in man has not resolved the question as to the exact site of the reentry circuit: an exclusively intranodal pathway or a pathway involving part of the atrium? The remarkable efficacy of modern radical therapy of this arrhythmia with preservation of atrioventricular conduction reinforces the concept of reentry involving not only the atrioventricular node but also the juxta nodal atrium and the superior and inferior atrionodal connections. Radical treatment was initially surgical and then by catheter ablation. The technique of specific ablation of the rapid anterior pathway was the first to be described. Its limitation is the relatively high risk (about 10%) of complete atrioventricular block. Very quickly, radiofrequency ablation of the slow posterior pathway became the method of reference. Most patients do not have retrograde conduction in the slow pathway. The pathway is located in sinus rhythm by recording its specific potentials: either the rapid potential described by Jackman et al or the fragmented potential described by Haïssaguerre and Warin. The former is recorded from the posterior septal position anterior to the orifice of the coronary sinus; the second is recorded at the same level but slightly above in the mid septal position. Ablation of the slow pathway can be performed on these purely anatomical criteria. Using these approaches, an immediate success rate of over 90% may be obtained. The recurrence rate is 0 to 5%; that of complete atrioventricular block ranges from 0 to 4%.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

[Automatic implantable defibrillators: long-term results].

The automatic implantable defibrillator is an essential component of the preventive management of sudden death of patients with malignant ventricular arrhythmias. Though its efficacy in this indication is not contested, the data concerning its influence on global cardiac mortality is more controversial. The elements of this controversy are reviewed. Several prognostic factors are implicated, the principal of which being the patient's haemodynamic status as assessed by objective evaluation of left ventricular function. Prospective randomised studies comparing medical therapy with the automatic implantable defibrillator are under way and should provide a better understanding of its indications in the future.

Arrhythmias, Cardiac↗

[Right accessory pathways with slow and decremential anterograde conduction. Electrophysiological changes during ablation of the proximal atrial poles].

Right sided accessory pathways with slow and decremential anterograde conduction differ from the anatomical substrates of the nodo-ventricular connections described by Mahaim. The connection may also be atrio-ventricular or atrio-fascicular. The authors report a series of 6 patients (2 men, average age 31 +/- 9 years) with antidromic reciprocating tachycardia implicating accessory pathways with decremential conduction (wide QRS complexes with left bundle branch block) the radiofrequency ablation of which was centered on the proximal atrial pole. The increment of pre-excitation was 75 +/- 18 ms. No nodo-ventricular or nodo-fascicular connections were observed. One patient had an atrio-ventricular connection, the mapping and ablation (5 applications) of which were performed on the annulus, as if it were a bundle of Kent. Five patients had a nodo-fascicular connection which was masked during sinus rhythm. The localisation of the proximal atrial insertion on the tricuspid annulus was initially estimated by studying the superior junction of the circuit and by endocavitary stimulation, and then by recording the M potential (activation of the accessory pathway). This was recorded in 4 patients, either at a specific point on the annulus (lateral or postero-lateral) which was the target of ablation (3 patients, 5 +/- 3 applications) or over a wider region (2 cm) at which ablation failed (1 patient: 13 applications). The site of the increment was determined in 2 patients and was proximal to the M potential. The M potential could not be recorded on the annulus in one patient. In 2 patients, the M potential was also recorded along the side of the pathway on the antero-lateral wall of the right ventricle of the tricuspid valve at its distal pole. In 2 patients, ablation was centered on the distal pole in second intention, near to the terminal part of the right bundle where it was localised in one of the two (18 applications). Finally, ablation was obtained in 5 out of 6 patients. They remain asymptomatic after 12 +/- 7 months follow-up. These cases show that accessory pathways with slow decremential conduction usually behave like a complete conduction pathway with an accessory laterally situated atrioventricular node on the tricuspid, an accessory bundle and a distal insertion which are all accessible to ablation.

Adolescent↗

[Value of searching ventricular late potentials in patients recovering from ventricular fibrillation].

The prognostic value of ventricular late potentials (VLP) was studied in 38 survivors of ventricular fibrillation (VF) resuscitated after cardiac arrest. Thirty-seven patients had coronary artery disease, 24 within one month of myocardial infarction, and one patient had valvular heart disease. There were 7 deaths within 2 years, including 5 sudden deaths, the average follow-up in the remaining patients being 46 +/- 30 months. Bad prognostic factors included low left ventricular ejection fraction, anterior myocardial infarction, VF occurring after the first 24 hours of myocardial infarction and the presence of VLP. The 2 year mortality rate was 35% in patients with VLP compared with only 5% when they were absent (p < 0.05). The subgroup with the highest risk of death was that of anterior myocardial infarcts with VLP (45% 2 year mortality). The clinical circumstances surrounding VF were important; patients with clinical and electrical signs of ischaemia at the time of VF tended to have a better prognosis than the others, especially in the absence of VLP: in this subgroup of 12 "ischaemic" VFs without VLP the mortality at 2 years was nil, whereas the other 26 patients had a 27% death rate (0.05 < p < 0.10). Programmed ventricular stimulation was only carried out in 14 cases: it showed that the long-term mortality was very high (60%) in patients with VLP and inducible ventricular tachycardia (VT). Therefore, the implantation of an automatic defibrillator device would seem to be justified in patients resuscitated from VF who have both VLP and inducible VT, but of no value in cases of "ischaemic" VF without VLP.

Action Potentials↗

[Indications for implantable automatic defibrillators].

The automatic implantable defibrillator is an effective therapeutic tool for palliative treatment of severe ventricular arrhythmias. There is a significant reduction in sudden death in implanted patients. However, reliable data on the long term global mortality is not yet available. The indications are difficult to define apart from special cases. A large number of factors has to be taken into consideration: the clinical presentation of the arrhythmia, and the different medical and non-medical therapeutic options. At present, it is not possible to arrive at a consensus on the indications of automatic implantable defibrillators. Therefore, it is illusory to construct decisional algorithms. The authors suggest therapeutic orientations rather than strict clinical indications, based on recommendations published by the working groups on cardiac arrhythmias and pacing of the European Society of Cardiology and on their own personal experience.

Death, Sudden, Cardiac↗

Diagnostic and prognostic value of coronary arteriography.

Coronarography can be used as a diagnostic test when the clinical evaluation and the non-invasive test are inconclusive, although some conceptual problems remain. In known ischemic heart disease, the estimation of the prognosis is an important factor for the treatment decision, but coronary arteriography does not give a clear picture, and apart from the most severely ill patient, the prognosis usually remains very difficult to evaluate.

Coronary Angiography↗

Flecainide in quinidine-resistant atrial fibrillation.

Flecainide (100 mg twice daily) was used for prevention of paroxysmal atrial fibrillation (PAF) in 52 patients with frequent symptomatic attacks that were resistant or intolerant to quinidine (600-900 mg/day). Underlying heart disease was present in only 8 cases and left ventricular ejection fraction was always greater than 30%. No patient had had a myocardial infarction. Vagally induced PAF was clinically documented in 35 patients. Amiodarone, previously used and ineffective, was combined with flecainide in 33 patients. After 1-5.8 years of follow-up, complete disappearance of PAF was observed in 38 patients (73%). The success rate was slightly higher in patients with vagally induced PAF (p = 0.07). Extracardiac side effects necessitated withdrawal in only 3 cases. Permanent pacemaker was needed in 7 patients on amiodarone and flecainide because of excessive sinus bradycardia. Two patients, with previously documented atrial flutter, experienced presyncopal episodes of atrial flutter with 1:1 atrioventricular (AV) conduction and wide QRS complex. No death occurred during the follow-up. In this series, quinidine proved to be unsuccessful in 46 patients and it was withdrawn in 6. We concluded that flecainide is efficient and well tolerated for long-term prevention of PAF in patients resistant to quinidine. The possibility of 1:1 AV conduction during atrial flutter may suggest the use of verapamil or beta blockers in combination with flecainide in patients with previously documented atrial flutter.

Amiodarone↗

Improvement of digital coronary angiography: high resolution processing coupled with a real time functional synchronization procedure.

The use of Digital Subtraction Angiography in coronary applications is restricted by the difficulty in: 1. Obtaining a good resolution of the distal branches. 2. Avoiding, for the purpose of subtraction, the motion artifacts induced by artery and background displacement during the cardiac and respiratory cycles. 3. Preserving the dynamic vascular motion. 4. And storing the digital dynamic information on a permanent support. We used for this study an angiography system, based upon a high resolution 45 MIPS-32 Mbyte image processor, interfaced with a 2.75 Gbyte Winchester drive allowing the real time storage of either 30 frames/s in the 512*512*8 bits matrix or of 7.5 f/s in the 1024*1024*8 bits matrix. To preserve the most important dynamic informations on the basis of the 7.5 f/s maximal storage rate, we developed a synchronization device able to recognize in real time, from chronologic delays derived by using both ECG and Aortic Pressure curves, the functional End-Diastolic (ED) and the End-Systolic (ES) positions, even in the case of heart rates varying during the procedure. The ED and the ES images are stored together with the Mid-Systolic (MS), the 1/3-Diastolic (1/3D) and 2/3-Diastolic (2/3D) images. To establish the validity of this sampling method, which uses a reduced number of frames per cardiac cycle, 7200 coronary injections performed during 450 routine coronary angiographies were compared by two independent observers (A and B), using: first a Digital (D) 5 frames/cycle sequence, and secondly a cine Film (F) 50 frames/s sequence acquired immediately after the corresponding D injection. The D technique resulted in the best image and diagnostic quality, particularly when the F quality was estimated 'fair' or 'poor' by both observers, and in an important reduction on X-Ray doses. The visualisation of the sequential ED, MS, ES, 1/3D and 2/3D frames gives the possibility: 1. of saving the dynamic information, as a regular sample of functional images can be displayed with a cine loop technique. 2. of facilitating cardiac synchronized subtractions. 3. of reducing the amount of frames per cycle, thus allowing an important reduction of X-ray doses and the digital and permanent storage of the most important cardiac cycles.

Angiography, Digital Subtraction↗

Efficacy of beta-blocking agents in reducing the number of shocks in patients implanted with first-generation automatic defibrillators.

The efficacy of beta-blockers was tested in 11 patients who avoided sudden death as a result of ventricular tachycardia or fibrillation due to coronary artery disease or non-ischaemic underlying heart disease, after implantation of an automatic defibrillator. Ten patients initially tolerated acebutolol despite prior class III or IV heart failure in six cases; nadolol replaced acebutolol in nine cases for long-term therapy. In these 10 patients, periods of treatment with and without beta-blocking agent were available, making possible a crossover comparison, during a follow-up lasting 31.6 +/- 17.8 months. One hundred and ten shocks were delivered: 14 were considered as probably inappropriate and ruled out, leaving the remaining 96 shocks to be analysed. The monthly rate of shocks was lower during beta-blocking treatment: 0.12 +/- 0.24 vs. 1.09 +/- 1.41 (P = 0.03). While taking beta-blockers, only four patients received shocks, compared to 10 (i.e. all cases) not administered beta-blockers (P less than 0.01). Despite the technical limitations of the study, since only a few spontaneous shocks could be documented on ECG recordings, the efficacy of beta-blockers in preventing occurrence of severe ventricular tachyarrhythmias seems likely, and deserves further investigations using new implanted devices with improved memory functions.

Acebutolol↗

[Pro-arrhythmia effect of pyridostigmine. Apropos of a case].

A coronary patient with myasthenia gravis with a previous myocardial infarction presented with severe ventricular arrhythmias after the replacement of neostigmine by pyridostigmine for the treatment of the myasthenia. These arrhythmias were resistant to antiarrhythmic therapy associating betablockers and amiodarone throughout treatment with pyridostigmine but regressed when this drug was withdrawn. A test of reintroduction of pyridostigmine under medical surveillance led to the reappearance of the ventricular hyperexcitability, so confirming the responsibility of this drug. This would seem to be the first reported case of severe ventricular arrhythmias due to a proarrhythmic effect of pyridostigmine. The possible mechanisms of this effect are discussed.

Coronary Disease↗

[Clinical aspects of polymorphic ventricular tachycardia].

Polymorphic ventricular tachycardia is defined as constant change of the QRS morphology. The diagnosis has important etiological, therapeutic and prognostic implications. This term covers several different entities which may be artificially distinguished by the electrocardiographic appearances during tachycardia, by changes of the resting electrocardiogramme, the mode of onset, the presence or absence of underlying cardiac disease and of intercurrent drug therapy. However, as the resting ECG may not be available in an emergency situation, or difficult to interpret, the clinical context is the key to diagnosis and treatment. Polymorphic ventricular tachycardia is classified according to the absence or presence of underlying cardiac disease respectively as torsades de pointe with long QT, torsades de pointe with a short coupling interval and catecholamine-induced ventricular tachycardia of childhood on the one hand, and, iatrogenic torsades de pointe, ventricular tachycardia in acute or chronic infarction and other cardiac diseases, on the other hand. Finally, the authors discuss the problem of polymorphic ventricular tachycardia induced by programmed ventricular stimulation.

Anti-Arrhythmia Agents↗

[Value of signal-averaged electrocardiogram in ventricular arrhythmia without apparent heart disease].

Signal-averaged electrocardiography was performed in 132 subjects with various ventricular arrhythmias without clinically apparent heart disease and compared with the results obtained in a series of 45 normal subjects. The latter enabled definition of the following criteria of normality: QRS duration after averaging < 113 ms; Simson vector of the last 40 ms (RMS40) > or = 17 microV; low amplitude signal duration over 40 microV < 38 ms for a high pass bidirectional filter of 40-300 Hz. Complementary investigations (echo or angiography), performed in all cases, showed underlying abnormalities in 26 patients: 13 right ventricular dysplasias, 7 cardiomyopathies, 3 mitral valve prolapses and 3 minor congenital heart defects. These investigations were normal in the remaining 106 subjects. Of the 26 patients with cardiac disease, 15 had 3 criteria of positivity for late ventricular potentials, 6 had 2 criteria and the other 5 had no criteria of late ventricular potentials. Therefore, 81% of cases with cardiac disease had at least 2 diagnostic criteria of late ventricular potentials whereas only 4% of those without cardiac disease, and in the control group, had criteria of positivity (p < 0.001). Using these criteria, the predictive value of signal-averaged electrocardiography for the detection of underlying cardiac disease was good when 2 criteria are required for diagnosis of late ventricular potentials: sensitivity 81%, specificity 96%; predictive value of a positive test 78%, predictive value of a negative test 97%. Signal-averaged electrocardiography is therefore a good non-invasive method of diagnosing underlying cardiac disease in patients with ventricular arrhythmias without clinically apparent heart disease.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Long-term follow-up after sustained monomorphic ventricular tachycardia: Causes, pump failure, and empiric antiarrhythmic therapy that modify survival.

We analyzed the actuarial cardiac mortality rate of 295 consecutive patients with sustained monomorphic ventricular tachycardia who were referred to us between 1978 and 1988. Patients were divided into four groups: group I of 156 patients with coronary disease, group II of 55 patients with nonischemic left ventricular disease, group III of 65 patients with right ventricular disease, and group IV of 19 patients without detectable heart disease. Patients were treated empirically according to a prospective schema: (1) class I antiarrhythmic drugs, (2) in case of recurrence of ventricular tachycardia: amiodarone or beta-blockers, (3) in case of recurrence of ventricular tachycardia: drug combinations or surgery. The mean follow-up duration was 61 +/- 40 months after the first occurrence of ventricular tachycardia, and the clinical outcome was known in 67.5% of patients at 5 years. The actuarial mortality rates were considerably higher in groups I and II compared with those in groups III and IV (p less than 0.01). The mortality rate was slightly higher in group I than in group II (p less than 0.05). In groups I and II, actuarial mortality rate were much higher when left ventricular ejection fraction was less than 0.30 (p less than 0.01). Comparisons between treatments showed no difference in actuarial mortality rates in patients with ventricular tachycardia and left ventricular ejection fraction greater than 0.30.(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis↗

Sudden cardiac death, implanted defibrillation, and clinical electrophysiology.

A mere 25 years ago, the technique of external defibrillation became the starting point for the development of clinical electrophysiology by permitting routine use of endocavitary programmed electrical stimulation of the heart without undue risk. Major advances in knowledge of clinical arrhythmias and the understanding of their mechanisms were, thus, permitted. Mirowski's implanted defibrillator also constituted a major breakthrough therapeutically; unfortunately, however, some 10 years later, it has not yet induced similarly hoped for consequences in terms of progressing knowledge concerning lethal arrhythmias, largely due to the absence of Holter functions in the implanted devices. As a result of this, in our opinion, better established therapeutic indications are still needed. The reasons for the present situation, we believe, may be partly technical but are conceptual as well. The key point is that even the clear demonstration of the great practical efficacy of a therapeutic tool does not exempt us from the obligation of determining the mechanisms of this effect.

Arrhythmias, Cardiac↗

[Implantable automatic defibrillator. Evaluation after 8 years of use].

The thirty nine patients (30 men and 9 women, mean age 49 +/- 14 years) who were implanted with an automatic cardioverter defibrillator (AICD) between October 1982 and April 1990 were reviewed retrospectively. This group included 22 patients with ischaemic cardiomyopathy (55%), 9 primary cardiomyopathies (23%) 5 ventricular tachycardias in patients with normal hearts (13%), 1 case of arrhythmogenic right ventricular dysplasia and two of mitral valve prolapse. The mean ejection fraction for the whole group was 38 +/- 14%. The indication for implantation of the AICD was life-threatening ventricular arrhythmias for which other forms of treatment were either ineffective (29 patients), impossible to assess (9 patients) or poorly tolerated (1 patient). Two patients died during the perioperative period and the follow-up is too short in two other cases. Therefore, 35 patients were studied over an average of 23.7 +/- 16 months. During follow-up, 5 patients died, 3 of progressive cardiac failure and 2 suddenly, one of whom was waiting for a replacement of an exhausted generator. The AICD never functioned in 40% of patients. In addition, it was impossible to determine for the majority of shocks delivered if they had been triggered by a sustained ventricular arrhythmia. Long term tolerance was generally good but two patients developed cardiac constriction induced by the epicardial patch electrodes. The results of this review confirm the efficacy of AICD in preventing sudden death at the expense of a low operative mortality and with good long term tolerance. Quite a large proportion of AICDs never functioned and the interpretation of the delivered shocks remains questionable.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗