PubMed HealthSearch

Biomedical subjects

R Spear

Publications and source records attributed to R Spear.

6 recordsLinked to original sources

Appendiceal US scans: histologic correlation.

High-resolution in vitro ultrasonography (US) of 20 surgical appendiceal specimens was performed to compare appearances of appendiceal tissue at US with corresponding histologic features. With an articulated-arm system and micropositioner, precise spatial correlation was achieved. As elsewhere in the gastrointestinal tract, five distinct echo layers were observed. Normal and inflamed specimens demonstrated these layers, but the architecture became disorganized and indistinct in cases of appendicitis. Three measurements were made for each specimen: (a) overall cross-sectional diameter, including the lumen, (b) thickness of the submucosal echo layer, and (c) the combined thickness of both walls, excluding the lumen. For the inflamed specimens, a substantial increase in the thickness of the summed wall measurements was found. Wall US appearance alone may be misleading in differentiation of normal and abnormal appendices.

Adolescent

A transportable, remote sensing, infrared air-monitoring system.

A transportable, remote sensing instrument has been built that is capable of performing real-time quantitative analysis of gas and vapor contaminants of workplace air. The emphasis in this system is on simplicity and sensitivity for use over pathlengths of up to 40 m. A method was developed to overcome the effect of nonanalyte species present in the background spectrum on the quantitation of analytes in the sample spectrum. In addition, results demonstrated that instrument response was proportional to the beam pathlength under homogeneous concentration conditions. The application of software capable of qualitative analysis was also demonstrated.

Air Pollutants, Occupational

The effect of autocorrelation on the estimation of workers' daily exposures.

Daily 8-hr time-weighted average (TWA) measurements may not be independent since production rates, maintenance schedules, work practices, and ventilation can result in trends where consecutive values are correlated (autocorrelation). A sampling program which involves collection of measurements on consecutive days, therefore, can result in biased estimates of the mean and variance of the exposure distribution if a high degree of autocorrelation exists. Three simulated data sets were examined to assess the effects of autocorrelation on the estimation of exposure distributions. Results indicated that about 30% of estimated mean values from a highly-autocorrelated series were outside the 95% confidence interval observed for an uncorrelated series. Three data sets obtained from actual workplaces were found to have relatively little autocorrelation. This suggests that for workplaces such as those analyzed here, a random sampling program may not be necessary, and sequential sampling may produce accurate estimates of the parameters of the exposure distribution.

Air Pollutants, Occupational

A note on the assessment of exposure using one-sided tolerance limits.

Conceptual problems with OSHA's use of an absolute standard have led to alternative methods of assessing exposures to toxic materials in the workplace. One of these methods employs a one-sided tolerance limit. This statistical approach is explored from three points of view--identifiability, sampling strategies and statistical power. In general, assessing risk in the work environment with tolerance limits is found to give inadequate answers in several important respects.

Humans

Effects of coronary artery ligation and release and perfusion with glucose on cardiac energy metabolism in dogs.

Adenosine triphosphate (ATP), glycogen, and inorganic phosphorus (Pi) were assayed in myocardial tissues obtained from beating dog hearts subjected to the following procedures: Group 1. Ligation of anterior descending coronary artery(AD) for 60 min. Group 2. Perfusion of the AD with 20 mM glucose in Ringer's solution containing 1 mU regular insluin/ml, for 60 min. Group 3. Ligation of the AD for 60 min, followed by release of the ligature with re-establishment of blood flow for 30 min. Group 4. Perfusion of the AD with 20 mM glucose in Ringer's solution containing 1 mU/ml regular insulin for 60 min, followed by re-establishment of blood flow for 30 min. Samples from normal myocardium (N zone) and from the area supplied by the AD (I zone) were simultaneously obtained and the level of metabolites compared. In all four groups, ATP was significantly lower in I than N zone. However, ATP values were lower in N zone in group 1 as compared with the other groups (p less than 0.05) and higher in I zone in group 3 versus groups 1 and 2 (p less than 0.05). Glycogen was lower in I than N zones to a similar degree in all the groups. However, it was higher in the I zone in group 3 than in group 1 (p less than 0.05). Pi was significantly higher in I zone versus N zone only in group 1 (p less than 0.05). These data suggest that, the the beating dog heart, ATP and glycogen preservation in a myocardial segment rendered ischemic for 1 hour is best achieved by re-establishing circulation. Glucose infusion into the ischemic segment did not contribute significantly to the ATP stores in that segment but may have exerted a protective effect on the nonischemic zones, possibly by providing a high glucose level in the circulating blood. This protection was equally well achieved by release of the ligature with or without prior glucose infusion. The increase in Pi in the ischemic zone in the dogs with coronary ligation only is probably related to accumulation of the ion under ischemic and hypoxic conditions.

Adenosine Triphosphate