PubMed Health⌕ Search

Biomedical subjects

R Splinter

Publications and source records attributed to R Splinter.

15 recordsLinked to original sources

Quantifying spatial localization of optical mapping using Monte Carlo simulations.

Optical mapping techniques used to study spatial distributions of cardiac activity can be divided into two categories. 1) Broad-field excitation method, in which hearts stained with voltage or calcium sensitive dyes are illuminated with broad-field excitation light and fluorescence is collected by image or photodiode arrays. 2) Laser scanning method, in which illumination uses a scanning laser and fluorescence is collected with a photomultiplier tube. The spatial localization of the fluorescence signal for these two methods is unknown and may depend upon light absorption and scattering at both excitation and emission wavelengths. We measured the absorption coefficients (micro a), scattering coefficients (micro s), and scattering anisotropy coefficients (g) at representative excitation and emission wavelengths in rabbit heart tissue stained with di-4-ANEPPS or co-stained with both Rh237 and Oregon Green 488 BAPTA 1. Monte Carlo models were then used to simulate absorption and scattering of excitation light and fluorescence emission light for both broad-field and laser methods in three-dimensional tissue. Contributions of local emissions throughout the tissue to fluorescence collected from the tissue surface were determined for both methods. Our results show that spatial localization depends on the light absorption and scattering in tissue and on the optical mapping method that is used. A tissue region larger than the laser beam or collecting area of the array element contributes to the optical recordings.

Animals↗

Laser photoablation of experimental post-infarction ventricular tachycardia guided by three dimensional activation mapping.

BACKGROUND AND OBJECTIVE: The purpose of this study was to evaluate the efficacy of epicardially delivered laser energy to ablate induced ventricular tachycardia in a post-infarction canine model. STUDY DESIGN/MATERIALS AND METHODS: In 13 canines, the left anterior wall myocardial infarction was created. Five days later, 240 plunged electrodes were inserted into the heart. Three-dimensional ventricular activation sequences were analyzed on line by a computerized mapping system. RESULTS: Sixteen sustained monomorphic ventricular tachycardias were reproducibly induced in 10 canines. Epicardially contacted Nd:YAG laser irradiated the areas of the final pathway in macro-reentrant activation and the impulse origin in focal excitation. Linear photocoagulation lesions (11-16 x 50-72 mm) were created. Seven macro-reentrant circuits and six of nine focal origins were eliminated (success rate 81%). Pathology showed that laser photocoagulation involved all surviving subepicardial and intramural fibers. CONCLUSION: Epicardially delivered laser energy in conjunction with electrical activation mapping has a high probability of ablating post-infarction ventricular tachycardia.

Animals↗

Selective coagulation necrosis of canine adventitia and media induces extracellular matrix accumulation without neointima formation.

Endothelial cell injury, the disruption of the internal elastic membrane and medial damage represent important stimuli for the development of a neointima. It is unclear whether selective adventitial and medial injury also induce neointima formation. Incremental argon laser energies (11.4-180 J/cm2) were applied to the external surface of dog femoral arteries to evaluate the vascular repair of acute adventitial or medial necrosis without injury of the intima. The animals were sacrificed either one hour after the initial procedure or after an 8 week follow up period for histologic examination. Acute, and mild to moderate necrosis of the arterial wall was found above 50 J/cm2. Ablation of the internal elastic membrane or mural thrombi was not detected. Eight weeks after photocoagulation with laser energies above 50 J/cm2, a significant increase in mean wall thickness of the media was observed. The medial thickening was characterised by an accumulation of extracellular matrix and a loss of smooth muscle cells. Necrosis of adventitia and media resulted in arterial wall thickening without neointima formation. It is concluded that, in dogs, an acute, selective injury of adventitia and media stimulates the production of extracellular matrix and not the proliferation of cells. Smooth muscle cell migration and subsequently neointima formation are induced by viable smooth muscle cells when blood-borne stimuli are available.

Analysis of Variance↗

Myocardial temperatures during in vivo endocardial Nd:YAG laser irradiation.

To determine safety and efficacy of neodymium:YAG laser irradiation of the endocardium, temperatures at both the epicardium and the endocardium were recorded for thermal damage evaluation. A total of 48 coagulation lesions were created at power settings of 20 and 30 W in 20 open chest dogs by transcatheter endocardial laser irradiation. Tissue temperatures were monitored by epicardial thermography (Tepi), and by endocardial thermocouples at the catheter tip (Tprox) and 4 mm below the endocardial surface (Tdist). In group I the optical fiber extended 1 mm from the catheter and irradiation times ranged from 3 to 60 sec. Tepi reached > or = 57 degrees after a weighted average of 5 sec of laser irradiation (n = 44). In group II the fiber was retracted 1 mm from the catheter tip, and irradiation times were 100 to 150 sec. Tepi reached > or = 57 degrees C after a weighted average of 30 sec (n = 4). Blood vessels were recognized as heat sinks until coagulation occurred. Lesion volume showed a proportional increase with total delivered energy. From the observed timeframes in epicardial temperature rise it is suggested that total direct light absorption at the epicardium was the main contribution to Tepi, and the Nd:YAG laser can efficiently create transmural lesions. The epicardial temperatures remained below 80 degrees C in combination with the constant movement of the epicardial wall suggested safety from thermal damage to the ambient organs.

Animals↗

Ultrasonic characterization of myocardial photocoagulation lesion size in vivo during Nd:YAG laser irradiation.

Endocardial coagulation lesions were created using transcatheter continuous-wave Nd:YAG laser irradiation. Ultrasound monitoring of thermal lesion dimensions was performed using 7.5-MHz and 10-MHz transducers directly from the epicardial surface in short-axis configuration (group A) or through the chest wall (group B). A total of 33 lesions were created in 10 dogs at energy levels ranging from 300 J to 1000 J. Mean histological lesion width (HW) compared with ultrasonically determined mean width (UW) showed that the differences (mean +/- standard deviation) in group A (UW - HW) was = 1.14 +/- 0.8 mm, which was not statistically significantly different from zero. In group B, (UW - HW) = 2.04 mm +/- 0.7 mm (p < .05), which was statistically significantly different from zero. Mean histological depth (HD) differentially related to ultrasound mean depth (UD) for group A and B combined showed (UD - HD) = -0.19 mm +/- 0.46 mm, not statistically significantly different from zero. The frequency distribution for width in group A showed magnitude of UW-HW > 3 mm in 32% of cases. In group B magnitude of UW-HW > 3 mm in 15%, whereas ultrasound width was larger than histology in 75% of the cases. For depth, magnitude of UD-HD > 3 mm in 15% of cases. With further refinement of the technique, ultrasonic tissue characterization may become a useful adjunct to monitoring lesion dimensions during transcatheter laser photocoagulation.

Animals↗

Neodymium:YAG contact laser photocoagulation of the in vivo canine epicardium: dosimetry, effects of various lasing modes, and histology.

UNLABELLED: Neodymium:YAG laser photocoagulation (LPC) is an investigational technique for the treatment of drug-resistant postinfarction ventricular tachycardia that requires cardiopulmonary bypass and open heart surgery. The purpose of this experimental study was to evaluate the feasibility of contact epicardial LPC to reach subepicardial, deep myocardial, and subendocardial regions without ventriculotomy and to analyze the dose-response relationships of this new technology. In 24 open-chest, closed heart dogs, a total of 219 epicardial laser lesions were generated under sterile conditions. Laser source was a continuous wave 1064 nm Nd:YAG; the delivery system consisted of a 400 mu bare quartz fiber fed into an 8F electrode catheter in direct contact with the epicardial surface. Laser variables were power at 10-15-20 W; lasing time, 6-12-18-24 s; lasing mode, continuous and pulse-pause; fiber mode, optical fiber tip inside and extending out from the electrode catheter. Hearts were harvested at 1 week. Histologic measurements included lesion surface diameter, internal diameter, and depth. RESULTS: Significant linear correlation was found between the total delivered energy and all measured lesion parameters. Transmural lesions were found at energy levels of 270-480 J. Maximum depth measured up to 1.68 cm; at high energies, it was limited by myocardial thickness only. At constant energy levels, power and lasing time did not independently affect lesion dimensions; lasing mode and fiber mode had statistically significant but minor effects. Laser lesions were homogeneous and sharply demarcated without epicardial crater or endocardial thrombus formation. Endocardial surface cooling by circulating blood and the presence of epicardial vessels resulted in modifications in lesion morphology. In 29 out of 74 grossly transmural lesions, there was a 0.082 +/- 0.127 cm thin surviving subendocardium. Forty-five coagulation lesions were truly transmural with no surviving myocardial strands. In conclusion, contact epicardial LPC can result in deep, transmural myocardial coagulation lesions. Lesion dimensions can be adequately controlled by total delivered energy. Closed heart epicardial Nd:YAG laser photocoagulation could become a new, less invasive surgical technique for the treatment of drug-resistant ventricular tachycardia.

Aluminum Silicates↗

Selective elimination of retrograde conduction by intraoperative neodymium: YAG laser photocoagulation in dogs.

OBJECTIVES: The purpose of this study was to test the feasibility of selective elimination of ventriculoatrial (VA) conduction by limited laser photocoagulation of the atrioventricular (AV) node, and to analyze the histologic substrate of unidirectional retrograde block. BACKGROUND: Atrioventricular node reentry requires intact retrograde conduction. METHODS: Neodymium:yttrium-aluminum-garnet laser photocoagulation was performed during cardiopulmonary bypass through a right atriotomy in 15 dogs that had intact retrograde conduction before operation. Short laser pulses were delivered to an area between the coronary sinus orifice and the proximal His bundle. The end point of lasing was second-degree AV node block at a paced atrial cycle length of 250 ms. RESULTS: Complete retrograde block developed immediately in 11 of the 15 dogs (group I), while AV conduction persisted in all 11. In 4 of the 15 dogs (group II), both AV and VA conduction remained intact. During a 3-month follow-up period, retrograde conduction remained absent in all group I dogs. Retrograde block was not reversed by isoproterenol. Anterograde AV node characteristics (Wenckebach cycle length, functional refractory period, ventricular rate during atrial fibrillation) were unchanged in five dogs and modified in six. Complete AV block did not develop. In four control dogs (group III, sham operation), anterograde and retrograde AV node characteristics were unchanged. The anterograde Wenckebach cycle lengths in groups I, II and III at 3 months measured 192 +/- 15 ms, 195 +/- 6 ms and 170 +/- 22 ms, respectively, whereas the retrograde Wenckebach cycle lengths in groups II and III measured 345 +/- 62 ms and 278 +/- 25 ms, respectively. Histologic study at 3 months in cases with unidirectional VA block showed the compact part of the AV node intact with destruction of the atrial approaches and the superficial layers of the proximal end of the node on the right side. CONCLUSIONS: 1) With limited laser photocoagulation of the proximal AV node area, VA conduction can be eliminated and anterograde AV node transmission maintained. 2) Destruction of the atrial approaches on the right side with preservation of the compact part of the AV node may result in unidirectional retrograde block.

Animals↗

Catheterization technique for laser photoablation of atrioventricular conduction from the aortic root in dogs.

A simple catheterization technique for producing suppression or block of atrioventricular (AV) conduction in dogs by neodymium:YAG (Nd:YAG) laser photocoagulation from the aortic root is described. In 14 canines, electrode catheters were percutaneously advanced to the high right atrium, to the His bundle area at the tricuspid valve (right His [RH]), and the noncoronary cusp of the aortic valve (left His [LH]). A 400 microns optical fiber was fed into the lumen of the LH catheter. Continuous wave Nd:YAG lasing at lambda = 1,064 nm at 15-20 watts was performed at the site of the largest recorded LH deflection, opposite to the RH catheter, until complete AV block (CAVB, group I, eight dogs) or persistent A-H prolongation (AHPr, group II, four dogs) occurred; in two animals, laser photoablation was unsuccessful. CAVB and AHPr were achieved in < 140 seconds of lasing. Mean lasing time was 51 +/- 41 seconds, total energy delivered, 776 +/- 601 J. There were no complications. Dogs were followed for up to 120 days. In group I, 6/6 dogs followed for at least 1 week continued to have CAVB (three AV nodal, five infra-His). In group II, 1/4 dog progressed to infra-His CAVB; 3/4 had depressed AV nodal function. AV block was not reversed by isoproterenol. Aortic root angiograms revealed intact valve function in all. Histology showed various degrees of damage and repair of AV junctional tissue. There were no valvular perforations. Transcatheter Nd:YAG laser photocoagulation of the AV junction from the aortic root is a fast, simple, and safe method for creating AV conduction block in dogs.

Animals↗

Modification of atrioventricular node transmission properties by intraoperative neodymium-YAG laser photocoagulation in dogs.

The purpose of this study was to test the feasibility of neodymium-yttrium-aluminum-garnet (Nd-YAG) laser photocoagulation of the atrioventricular (AV) node to control the ventricular rate during rapid atrial rhythms without creating AV block. In 12 dogs on normothermic cardiopulmonary bypass, short laser pulses were delivered to an area between the coronary sinus orifice and the site of the most proximally recorded His deflection until second degree AV block occurred at a paced atrial rate of 200 beats/min. Long-term effects on AV node function were followed up for 3 months. Three animals developed chronic high grade AV block. In nine animals with preserved 1:1 conduction, the mean (+/- SEM) critical atrial cycle length resulting in AV node Wenckebach periodicity increased from 183 +/- 6 to 261 +/- 24 ms (+43%), the mean RR interval during induced atrial fibrillation increased from 248 +/- 14 to 330 +/- 27 ms (+32%) and the shortest RR interval during atrial fibrillation increased from 215 +/- 11 to 275 +/- 20 ms (+28%). Laser effects were not reversed by isoproterenol infusion. Histologic examination of the irradiated area showed fibrotic changes in the AV node and fatty metamorphosis. This study suggests that 1) graded Nd-YAG laser photocoagulation of the AV node region in dogs results in long-term modification of anterograde AV node transmission properties; 2) 1:1 conduction during sinus rhythm usually remains preserved, but ventricular rate during rapid atrial rhythms is chronically reduced; and 3) progression to high grade AV block occurs in a minority of animals.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Influence of probe motion on laser probe temperature in circulating blood.

The purpose of this study was to evaluate the effect of probe motion on laser probe temperature in various blood flow conditions. Laser probe temperatures were measured in an in vitro blood circulation model consisting of 3.2 nm-diameter plastic tubes. A 2.0 mm-diameter metal probe attached to a 300 microns optical quartz fiber was coupled to an argon laser. Continuous wave 4 watts and 8 watts of laser power were delivered to the fiber tip corresponding to a 6.7 +/- 0.5 and 13.2 +/- 0.7 watts power setting at the laser generator. The laser probe was either moved with constant velocity or kept stationary. A thermocouple inserted in the lateral portion of the probe was used to record probe temperatures. Probe temperature changes were found with the variation of laser power, probe velocity, blood flow, and duration of laser exposure. Probe motion significantly reduced probe temperatures. After 10 seconds of 4 watts laser power the probe temperature in stagnant blood decreased from 303 +/- 18 degrees C to 113 +/- 17 degrees C (63%) by moving the probe with a velocity of 5 cm/sec. Blood flow rates of 170 ml/min further decreased the probe temperature from 113 +/- 17 degrees C to 50 +/- 8 degrees C (56%). At 8 watts of laser power a probe temperature reduction from 591 +/- 25 degrees C to 534 +/- 36 degrees C (10%) due to 5 cm/sec probe velocity was noted. Probe temperatures were reduced to 130 +/- 30 degrees C (78%) under the combined influence of 5 cm/sec probe velocity and 170 ml/min blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗

Optical properties of normal, diseased, and laser photocoagulated myocardium at the Nd: YAG wavelength.

Laser photocoagulation of the myocardium effectively destroys arrhythmogenic foci. The purpose of this study was 1) to compare the optical properties of canine myocardium before and after photocoagulation, 2) to compare the canine model with clinical cases by measuring the optical properties of human myocardium, and 3) to assess the optical properties of human myocardial scar and epicardial fat tissue. Measured optical properties were the absorption coefficient, mu a; scattering coefficient, mu s; and scattering anisotropy factor, g. Optical measurements were performed at 1064 nm wavelength on thin plane parallel tissue slices using the integrating sphere method with glass hemispheres on either side of the sample. The study showed 1) an increase of the scattering coefficient by 40% and a two- to threefold increase in reduced scattering coefficient as a result of photocoagulation; 2) that the mu a (0.035 +/- 0.024 mm-1) and mu s (17.9 +/- 3.8 mm-1) of human myocardium were not significantly different from mu a (0.043 +/- 0.021 mm-1) and mu s (17.3 +/- 2.2 mm-1) of canine myocardium, whereas the human g (0.964 +/- 0.005) was slightly different from the canine g (0.974 +/- 0.008); and 3) that the mu a (0.021 +/- 0.016 mm-1) of epicardial fat and mu s (13.8 +/- 1.1 mm-1) of myocardial scar were significantly lower than those of normal myocardium. A dynamic model of laser-tissue interaction incorporating these changes and inhomogeneities is necessary to better describe light distribution during laser photocoagulation.

Animals↗

Electrophysiologic characteristics of manifest and latent retrograde conduction in dogs.

Atrioventricular (AV) nodal reentry requires intact retrograde ventriculoatrial (VA) conduction. The purpose of this study was to assess the contribution of various pacing and pharmacologic techniques to uncover VA conduction during apparent unidirectional VA block, and to evaluate the role of several biologic and electrophysiologic factors in concealment of retrograde conduction. Forty healthy dogs underwent catheter-electrophysiologic studies of AV and VA conduction. Group I (20 animals) had intact VA conduction. Group II (six animals) had VA dissociation with ventricular pacing initiated during sinus rhythm, but the presence of VA conduction was confirmed by isoproterenol infusion or by premature ventricular stimulation. In group III (14 animals), the above techniques failed to uncover VA conduction. Eight of 14 group III animals underwent thoracotomy and crushing or freezing of the sinoatrial (SA) node. Ventricular pacing initiated during sinus standstill was associated with 1:1 VA conduction in each experiment. VA conduction time and retrograde Wenckebach cycle length, both in the baseline state and during isoproterenol infusion, were significantly longer in the eight animals in group III than in those in group I. Age, gender, weight, breed, sinus cycle length, and anterograde AV conduction properties were not significantly different between groups I, II, and III. The data suggest that (1) in normal dogs, complete unidirectional VA block probably does not exist; (2) in the presence of anterograde input to the AV node, even sophisticated pacing and pharmacologic maneuvers may fail to uncover the presence of VA conduction; (3) although anterograde input is essential for concealment of VA conduction, the phenomenon is more closely associated with depressed retrograde than with anterograde AV nodal characteristics.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Drinking water and cancer incidence in Iowa. III. Association of cancer with indices of contamination.

With data from the Iowa Cancer Registry, age-adjusted sex-specific cancer incidence rates for the years 1969-1981 were determined for towns with a population of 1,000-10,000 and a public water supply from a single stable ground source. These rates were related to levels of volatile organic compounds and metals found in the finished drinking water of these towns in the spring of 1979. Results showed association between 1,2 dichloroethane and cancers of the colon and rectum and between nickel and cancers of the bladder and lung. The effects were most clearly seen in males. These associations were independent of other water quality and treatment variables and were not explained by occupational or other sociodemographic features including smoking. Because of the low levels of the metals and organics, the authors suggest that they are not causal factors, but rather indicators of possible anthropogenic contamination of other types. The data suggest that water quality variables other than chlorination and trihalomethanes deserve further consideration as to their role in the development of human cancer.

Adolescent↗