Mastication and swallowing in patients with postirradiation xerostomia.

PURPOSE: Very little objective data has been reported on mastication and swallowing in xerostomic patients, which would substantiate presumed causal relationships between xerostomia and patient complaints. The purpose was to elucidate which components of mastication and swallowing were abnormal, and most directly related to xerostomia, and which appeared unaffected. METHODS AND MATERIALS: A retrospective analysis of timing events in mastication and swallowing was done using videofluoroscopic data for 15 cancer patients with xerostomia, and 20 normal controls. Scintigraphy was also used to determine oropharyngeal residue after a water swallow. Cancer treatment modalities included radiation therapy or chemoradiation therapy. RESULTS: For barium liquid and paste substances, timing measures were equivalent for controls and patients. Xerostomic patients took 46% longer to masticate a shortbread cookie, and timing for the initiation of swallowing was shorter, but duration of swallowing appeared unaffected. Oral and pharyngeal residues following the swallow were greater in the patient group. CONCLUSIONS: Xerostomia primarily affected mastication and oral manipulation of a dry, absorbent food material. Increased oral and pharyngeal residues after a water swallow are ambiguously related to xerostomia. The initiation and duration of the pharyngeal swallow was not abnormal.

Aged↗

Normal adult swallowing of liquid and viscous material: scintigraphic data on bolus transit and oropharyngeal residues.

Scintigraphic data are provided for 20 normal control subjects, 39-65 years of age. Each subject swallowed 10 cc of water and 10 cc of a more viscous material (1,100 centipoise) consisting of apple juice thickened with Thick-It, a commercial food thickener. The test substances were combined with 2.5 mCi Tc-99m sulfur colloid. Scintigraphic data were acquired in dynamic mode for 10 sec at 25 frames/sec as the subject swallowed. Time-activity (TA) data were used to compute transit times, percentage residues in the mouth and pharynx, percent ingested, and a derived swallow efficiency score. The liquid was ingested in a single swallow by all subjects, and 9 cc was actually transferred to the esophagus. In contrast, for the viscous material, 11/20 subjects performed a second clearing swallow within the 10-sec interval. On the first swallow with the viscous substance, an average of 7 cc was transferred to the esophagus. Scintigraphy offers an excellent technique for determining natural and preferred volumes for swallowing a variety of bolus consistencies, since it can quantify the volume of each swallow or partial swallow. In this group of subjects the oral discharge time was shorter with the viscous material than with the water, but the pharyngeal transit times were not significantly different for the two bolus consistencies. Numerical efficiency scores were lower for the viscous material, indicating that such a measure is bolus dependent.

Adult↗

Quantifying aspiration in scintigraphic deglutition testing: tissue attenuation effects.

UNLABELLED: Scintigraphic studies for determining aspiration associated with swallowing have ignored error due to differential gamma attenuation in the patient by the various regions of the body. This study sought to estimate the magnitude of that error, and to assess the feasibility of providing individual attenuation corrections based on clinical data. METHODS: Relative attenuation for the pharynx, thorax and abdomen were determined from physical measurements employing an anthropomorphic phantom and 45 adult human subjects. A small sealed radioactive source of 2.5 mCi of 99mTc was placed inside the phantom at various locations within the upper digestive tract and respiratory system, and relative count rates determined via static scans with a gamma camera. Similar data for human subjects was obtained from clinical swallowing testing using a bolus of 2.5 mCi of 99mTc in 10 cc of water. RESULTS: The ratios representing relative counts were highly similar between the phantom and average human data. Test-retest replication of results was good for the abdominal reference and pharynx ratios--less so for the thorax. A procedure is described for estimating accuracy of percent aspiration calculation based on group data, using normalization coefficients derived for separate anatomical regions in the subglottic respiratory system. CONCLUSIONS: Error in percent aspiration calculation will depend on the amount and location of aspirate. Individual subject corrections based on the type of clinical data studied should be attempted with caution.