PubMed Health⌕ Search

Biomedical subjects

R Stagni

Publications and source records attributed to R Stagni.

3 recordsLinked to original sources

Mobility of the subtalar joint in the intact ankle complex.

A previous study by these authors showed that the calcaneus follows a unique path of unresisted coupled motion relative to the tibia during passive flexion and that most of this motion occurred at the ankle level. Subtalar motion in the intact ankle complex was observed only when perturbations from this path were induced by the application of force to the calcaneus. Relative motion of the bones of the ankle complex was tracked by stereophotogrammetry in seven specimens. Anatomical landmarks, reference frames and joint angles were defined by standard techniques. Sequential moments were applied to the calcaneus about the long axis of the tibia. Measured movements at subtalar level demonstrated plantarflexion coupled to supination and internal rotation (inversion) and dorsiflexion coupled to pronation and external rotation (eversion). These movements were resisted and were fully recovered when the external load was removed. Subtalar motion diminished as the ankle approached maximal dorsi- and plantarflexion. Two clearly distinguished mean axes of rotation were observed for inversion and eversion runs. The axes of inversion and eversion of the subtalar complex changed orientation along a preferred and repeatable path. The subtalar joint complex occupied only a single stable position in the unloaded state and with no range of unresisted motion. It is inferred that mobility was possible only by the stretching and lengthening of the ligaments and the indentation of the articular surfaces, requiring the application of loads. The subtalar joint complex behaves like a flexible structure.

Ankle Joint↗

Effects of hip joint centre mislocation on gait analysis results.

Methods to determine the hip joint centre (HJC) location are necessary in gait analysis. It has been demonstrated that the methods proposed in the literature involve large mislocation errors. The choice should be made according to the extent by which HJC location errors distort the estimates of angles and resultant moments at the hip and knee joints. This study aimed at quantifying how mislocation errors propagate to these gait analysis results. Angles and moments at the hip and knee joint were calculated for five able-bodied subjects during level walking. The nominal position of the HJC was determined as the position of the pivot point of a 3D movement of the thigh relative to the pelvis. Angles and moments were then re-calculated after having added to HJC co-ordinates errors in the range of +/-30 mm. Angles and moments at both hip and knee joints were affected by HJC mislocation. The hip moments showed the largest propagation error: a 30 mm HJC anterior mislocation resulted in a propagated error into flexion/extension component of about -22%. The hip abduction/adduction moment was found the second largest affected quantity: a 30 mm lateral HJC mislocation produced a propagated error of about -15%. Finally, a 30 mm posterior HJC mislocation produced a delay of the flexion-to-extension timing in the order of 25% of the stride duration. HJC estimation methods with minimum antero-posterior error should therefore be preferred.

Adult↗

Comparison of the myocardial effects of desflurane and isoflurane in healthy patients: assessment by continuous oesophageal aortic blood flow echo-Doppler.

Experimentally, desflurane causes a moderate positive inotropic effect and a transient increase in arterial pressure with rapid increases in concentration compared with isoflurane. We used a continuous oesophageal aortic blood flow echo Doppler device to study the myocardial effects of equi-anaesthetic concentrations of isoflurane and desflurane in 32 healthy patients undergoing superficial surgery. After induction of anaesthesia with midazolam, etomidate and fentanyl general anaesthesia was maintained in 16 patients with 0.6% end-expired concentration of isoflurane and in 16 patients with 3% end expired concentration of desflurane. Isoflurane induced a rapid decrease in aortic blood flow (ABF) which remained almost stable whereas desflurane induced an early, moderate and transient increase in ABF (1 min after introduction of the halogenated agent, mean ABF was 107 (SD 3)% in the desflurane group vs 95 (9)% in isoflurane group compared with control values before introduction of the inhalation agent; P = 0.005), followed by a marked secondary decrease in ABF. The maximal decrease in ABF reached 71 (15)% of its initial value in the desflurane group compared with 80 (14)% in the isoflurane group (ns). Neither agent caused significant changes in other variables except for PE'CO2 which decreased in both groups. Continuous ABF echo-Doppler monitoring demonstrated an early transient positive inotropic effect of desflurane.

Adolescent↗